343 related articles for article (PubMed ID: 23054771)
21. A high-flow portable biological aerosol trap (HighBioTrap) for rapid microbial detection.
Chen H; Yao M
J Aerosol Sci; 2018 Mar; 117():212-223. PubMed ID: 32372770
[TBL] [Abstract][Full Text] [Related]
22. [The prevalence of bacterial and fungal aerosol in homes, offices and ambient air of Upper Silesia. Preliminary results].
Lis DO; Pastuszka JS; Górny RL
Rocz Panstw Zakl Hig; 1997; 48(1):59-68. PubMed ID: 9273665
[TBL] [Abstract][Full Text] [Related]
23. Size-separated sampling and analysis of isocyanates in workplace aerosols. Part I. Denuder--cascade impactor sampler.
Dahlin J; Spanne M; Karlsson D; Dalene M; Skarping G
Ann Occup Hyg; 2008 Jul; 52(5):361-74. PubMed ID: 18458354
[TBL] [Abstract][Full Text] [Related]
24. [Assessment of fungal aerosol exposure at selected workplaces contaminated with organic dust of different origin].
Ławniczek-Wałczyk A; Cyprowski M; Gołofit-Szymczak M; Wójcik-Fatla A; Zając V; Górny RL
Med Pr; 2018 May; 69(3):269-280. PubMed ID: 29565046
[TBL] [Abstract][Full Text] [Related]
25. Field evaluation of a personal, bioaerosol cyclone sampler.
Macher J; Chen B; Rao C
J Occup Environ Hyg; 2008 Nov; 5(11):724-34. PubMed ID: 18780236
[TBL] [Abstract][Full Text] [Related]
26. [Bacterial and fungal aerosols in the work environment of cleaners].
Gołofit-Szymczak M; Górny RL; Ławniczek-Wałczyk A; Cyprowski M; Stobnicka A
Med Pr; 2015; 66(6):779-91. PubMed ID: 26674165
[TBL] [Abstract][Full Text] [Related]
27. Field evaluation of personal sampling methods for multiple bioaerosols.
Wang CH; Chen BT; Han BC; Liu AC; Hung PC; Chen CY; Chao HJ
PLoS One; 2015; 10(3):e0120308. PubMed ID: 25799419
[TBL] [Abstract][Full Text] [Related]
28. Endotoxin in Aerosol Particles from Metalworking Fluids Measured with a Sioutas Cascade Impactor.
Dahlman-Höglund A; Schiöler L; Andersson M; Mattsby-Baltzer I; Lindgren Å
Ann Work Expo Health; 2022 Feb; 66(2):260-268. PubMed ID: 34595500
[TBL] [Abstract][Full Text] [Related]
29. Exposure to Bacterial and Fungal Aerosols: Microorganism Indices in A Waste-Sorting Plant in Poland.
Brągoszewska E
Int J Environ Res Public Health; 2019 Sep; 16(18):. PubMed ID: 31505746
[TBL] [Abstract][Full Text] [Related]
30. Air sampling methodology for asphalt fume in asphalt production and asphalt roofing manufacturing facilities: total particulate sampler versus inhalable particulate sampler.
Calzavara TS; Carter CM; Axten C
Appl Occup Environ Hyg; 2003 May; 18(5):358-67. PubMed ID: 12746079
[TBL] [Abstract][Full Text] [Related]
31. Laboratory study of selected personal inhalable aerosol samplers.
Görner P; Simon X; Wrobel R; Kauffer E; Witschger O
Ann Occup Hyg; 2010 Mar; 54(2):165-87. PubMed ID: 20147627
[TBL] [Abstract][Full Text] [Related]
32. Bioaerosol assessment in naturally ventilated historical library building with restricted personnel access.
Harkawy A; Górny RL; Ogierman L; Wlazło A; Ławniczek-Wałczyk A; Niesler A
Ann Agric Environ Med; 2011; 18(2):323-9. PubMed ID: 22216807
[TBL] [Abstract][Full Text] [Related]
33. Indoor/outdoor relationships of bioaerosol concentrations in a retirement home and a school dormitory.
Faridi S; Hassanvand MS; Naddafi K; Yunesian M; Nabizadeh R; Sowlat MH; Kashani H; Gholampour A; Niazi S; Zare A; Nazmara S; Alimohammadi M
Environ Sci Pollut Res Int; 2015 Jun; 22(11):8190-200. PubMed ID: 25516249
[TBL] [Abstract][Full Text] [Related]
34. Field testing of new aerosol sampling method with a porous curved surface as inlet.
Hauck BC; Grinshpun SA; Reponen A; Reponen T; Willeke K; Bornschein RL
Am Ind Hyg Assoc J; 1997 Oct; 58(10):713-9. PubMed ID: 9342831
[TBL] [Abstract][Full Text] [Related]
35. Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.
Huang R; Agranovski I; Pyankov O; Grinshpun S
Indoor Air; 2008 Apr; 18(2):106-12. PubMed ID: 18333990
[TBL] [Abstract][Full Text] [Related]
36. Characterization of indoor bioaerosols from a hospital ward in a tropical setting.
Sudharsanam S; Swaminathan S; Ramalingam A; Thangavel G; Annamalai R; Steinberg R; Balakrishnan K; Srikanth P
Afr Health Sci; 2012 Jun; 12(2):217-25. PubMed ID: 23056031
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of bioaerosol sampling techniques for the detection of Chlamydophila psittaci in contaminated air.
Van Droogenbroeck C; Van Risseghem M; Braeckman L; Vanrompay D
Vet Microbiol; 2009 Mar; 135(1-2):31-7. PubMed ID: 18963601
[TBL] [Abstract][Full Text] [Related]
38. The influence of sampling duration on recovery of culturable fungi using the Andersen N6 and RCS bioaerosol samplers.
Saldanha R; Manno M; Saleh M; Ewaze JO; Scott JA
Indoor Air; 2008 Dec; 18(6):464-72. PubMed ID: 18761682
[TBL] [Abstract][Full Text] [Related]
39. Exposure to culturable and total microbiota in cultural heritage conservation laboratories.
Górny RL; Harkawy AS; Ławniczek-Wałczyk A; Karbowska-Berent J; Wlazło A; Niesler A; Gołofit-Szymczak M; Cyprowski M
Int J Occup Med Environ Health; 2016; 29(2):255-75. PubMed ID: 26670355
[TBL] [Abstract][Full Text] [Related]
40. Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler.
Stewart J; Sleeth DK; Handy RG; Pahler LF; Anthony TR; Volckens J
J Occup Environ Hyg; 2017 Mar; 14(3):207-213. PubMed ID: 27676440
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]