These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 23061116)

  • 1. Does pausing ultrafiltration as a treatment for intradialytic hypotension cause backfiltration in hemodialysis?
    Evans EC
    Nephrol Nurs J; 2012; 39(4):315-9. PubMed ID: 23061116
    [TBL] [Abstract][Full Text] [Related]  

  • 2. How should we manage adverse intradialytic blood pressure changes?
    Santos SF; Peixoto AJ; Perazella MA
    Adv Chronic Kidney Dis; 2012 May; 19(3):158-65. PubMed ID: 22578675
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrafiltration and backfiltration during hemodialysis.
    Ofsthun NJ; Leypoldt JK
    Artif Organs; 1995 Nov; 19(11):1143-61. PubMed ID: 8579527
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnosis and Treatment of Intradialytic Hypotension in Maintenance Hemodialysis Patients.
    McIntyre CW; Salerno FR
    Clin J Am Soc Nephrol; 2018 Mar; 13(3):486-489. PubMed ID: 29437702
    [No Abstract]   [Full Text] [Related]  

  • 5. Measurement of fluid volume shifts during hemodialysis by A-mode ultrasonography.
    Schumacher J; Rob P; Kreft B; Engelke A; Heringlake M; Klotz KF
    Blood Purif; 2000; 18(2):103-9. PubMed ID: 10838468
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reducing complications during hemodialysis using gradient ultrafiltration with gradient sodium dialysate.
    Meers C; Toffelmire EB; McMurray M; Hopman W
    ANNA J; 1999 Oct; 26(5):495-500; discussion 501, 505. PubMed ID: 10776077
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimal ultrafiltration profiling in hemodialysis.
    Yung J
    Nephrol Nurs J; 2008; 35(3):287-9. PubMed ID: 18649591
    [No Abstract]   [Full Text] [Related]  

  • 8. Reduced complications during hemodialysis by automatic blood volume controlled ultrafiltration.
    Garzoni D; Keusch G; Kleinoeder T; Martin H; Dhondt A; Cremaschi L; Tatsis E; Ibrahim N; Boer W; Kuehne S; Claus M; Zahn M; Schuemann E; Engelmann J; Hickstein H; Wojke R; Gauly A; Passlick-Deetjen J
    Int J Artif Organs; 2007 Jan; 30(1):16-24. PubMed ID: 17295189
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrafiltration profiling and measurement of relative blood volume as strategies to reduce hemodialysis-related side effects.
    Donauer J; Kölblin D; Bek M; Krause A; Böhler J
    Am J Kidney Dis; 2000 Jul; 36(1):115-23. PubMed ID: 10873880
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [HFR aequilibrium can be an answer to malnutrition and hypotension in dialisys: case report].
    Corino I; Ria P; Pertica N; Zaza G; Lupo A
    G Ital Nefrol; 2016; 33(6):. PubMed ID: 28134403
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The hemodynamic effect of different ultrafiltration rates in patients with cardiac failure and patients without cardiac failure: comparison between isolated ultrafiltration and ultrafiltration with dialysis.
    van der Sande FM; Mulder AW; Hoorntje SJ; Peels KH; van Kuijk WH; Kooman JP; Leunissen KM
    Clin Nephrol; 1998 Nov; 50(5):301-8. PubMed ID: 9840318
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The risks of high ultrafiltration rate in chronic hemodialysis: implications for patient care.
    Flythe JE; Brunelli SM
    Semin Dial; 2011; 24(3):259-65. PubMed ID: 21480996
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-Intensity Intradialytic Exercise Attenuates the Relative Blood Volume Drop Due to Intravascular Volume Loss during Hemodiafiltration.
    Rodríguez-Chagolla J; Cartas-Rosado R; Lerma C; Infante-Vázquez O; Martínez-Memije R; Becerra-Luna B; Pérez-Grovas H
    Blood Purif; 2021; 50(2):180-187. PubMed ID: 33454709
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of L-carnitine on dialysis-related hypotension and muscle cramps: a meta-analysis.
    Lynch KE; Feldman HI; Berlin JA; Flory J; Rowan CG; Brunelli SM
    Am J Kidney Dis; 2008 Nov; 52(5):962-71. PubMed ID: 18706751
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two variable sodium profiles and adverse effects during hemodialysis: a randomized crossover study.
    Meira FS; Figueiredo AE; Zemiarcki J; Pacheco J; Poli-de-Figueiredo CE; d'Avila DO
    Ther Apher Dial; 2010 Jun; 14(3):328-33. PubMed ID: 20609187
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of high and low ultrafiltration volume during hemodialysis on relative blood volume.
    Dasselaar JJ; de Jong PE; Huisman RM; Franssen CF
    ASAIO J; 2006; 52(2):169-73. PubMed ID: 16557103
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Using dialysis machine technology to reduce intradialytic hypotension.
    Davenport A
    Hemodial Int; 2011 Oct; 15 Suppl 1():S37-42. PubMed ID: 22093599
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The technological progress in haemodialysis: on-line hemodiafiltration].
    Racki S; Kes P; Basić-Jukić N
    Acta Med Croatica; 2008; 62 Suppl 1():44-8. PubMed ID: 18578332
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodiafiltration history, technology, and clinical results.
    Ronco C; Cruz D
    Adv Chronic Kidney Dis; 2007 Jul; 14(3):231-43. PubMed ID: 17603976
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A protocol-based treatment for intradialytic hypotension in hospitalized hemodialysis patients.
    Emili S; Black NA; Paul RV; Rexing CJ; Ullian ME
    Am J Kidney Dis; 1999 Jun; 33(6):1107-14. PubMed ID: 10352199
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.