1. Development of an isotope labeling ultra-high performance liquid chromatography mass spectrometric method for quantification of acylglycines in human urine. Stanislaus A; Guo K; Li L Anal Chim Acta; 2012 Oct; 750():161-72. PubMed ID: 23062437 [TBL] [Abstract][Full Text] [Related]
2. A novel method for quantitation of acylglycines in human dried blood spots by UPLC-tandem mass spectrometry. Fisher L; Davies C; Al-Dirbashi OY; Ten Brink HJ; Chakraborty P; Lepage N Clin Biochem; 2018 Apr; 54():131-138. PubMed ID: 29402417 [TBL] [Abstract][Full Text] [Related]
3. Stable isotope dilution analysis of n-hexanoylglycine, 3-phenylpropionylglycine and suberylglycine in human urine using chemical ionization gas chromatography/mass spectrometry selected ion monitoring. Rinaldo P; O'Shea JJ; Welch RD; Tanaka K Biomed Environ Mass Spectrom; 1989 Jul; 18(7):471-7. PubMed ID: 2775902 [TBL] [Abstract][Full Text] [Related]
4. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard. Jemal M; Schuster A; Whigan DB Rapid Commun Mass Spectrom; 2003; 17(15):1723-34. PubMed ID: 12872277 [TBL] [Abstract][Full Text] [Related]
5. Validation and application of an LC-MS/MS method for quantitation of three fatty acid ethanolamides as biomarkers for fatty acid hydrolase inhibition in human plasma. Jian W; Edom R; Weng N; Zannikos P; Zhang Z; Wang H J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Jun; 878(20):1687-99. PubMed ID: 20462810 [TBL] [Abstract][Full Text] [Related]
6. Quantitation of leukotriene B(4) in human sputum as a biomarker using UPLC-MS/MS. Jian W; Edom RW; Xue X; Huang MQ; Fourie A; Weng N J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Aug; 932():59-65. PubMed ID: 23831697 [TBL] [Abstract][Full Text] [Related]
7. Liquid chromatographic tandem mass spectrometric assay for simultaneous quantification of compound 97/78 and its in vivo metabolite 97/63, a novel trioxane antimalarial, in human plasma and its application to a protein binding study. Kushwaha HN; Gautam N; Singh SK Arzneimittelforschung; 2011; 61(7):425-32. PubMed ID: 21899212 [TBL] [Abstract][Full Text] [Related]
8. Development of a method for the determination of glycine in human cerebrospinal fluid using pre-column derivatization and LC-MS/MS. Wilson SF; James CA; Zhu X; Davis MT; Rose MJ J Pharm Biomed Anal; 2011 Sep; 56(2):315-23. PubMed ID: 21683541 [TBL] [Abstract][Full Text] [Related]
9. Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry. Johansen SS; Bhatia HM J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):338-44. PubMed ID: 17301000 [TBL] [Abstract][Full Text] [Related]
10. Simultaneous determination of asymmetric and symmetric dimethylarginine, L-monomethylarginine, L-arginine, and L-homoarginine in biological samples using stable isotope dilution liquid chromatography tandem mass spectrometry. Davids M; Swieringa E; Palm F; Smith DE; Smulders YM; Scheffer PG; Blom HJ; Teerlink T J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jul; 900():38-47. PubMed ID: 22682940 [TBL] [Abstract][Full Text] [Related]
11. High-performance liquid chromatography-mass spectroscopy/mass spectroscopy method for simultaneous quantification of total or free fraction of mycophenolic acid and its glucuronide metabolites. Figurski MJ; Korecka M; Fields L; Waligórska T; Shaw LM Ther Drug Monit; 2009 Dec; 31(6):717-26. PubMed ID: 19809389 [TBL] [Abstract][Full Text] [Related]
12. Liquid chromatographic-electrospray tandem mass spectrometric determination of clarithromycin in human plasma. Li W; Rettig J; Jiang X; Francisco DT; Naidong W Biomed Chromatogr; 2006 Nov; 20(11):1242-51. PubMed ID: 16838265 [TBL] [Abstract][Full Text] [Related]
13. Quantitative liquid chromatography coupled with tandem mass spectrometry analysis of urinary acylglycines: application to the diagnosis of inborn errors of metabolism. Ombrone D; Salvatore F; Ruoppolo M Anal Biochem; 2011 Oct; 417(1):122-8. PubMed ID: 21704015 [TBL] [Abstract][Full Text] [Related]
14. Strategies on efficient method development of on-line extraction assays for determination of MK-0974 in human plasma and urine using turbulent-flow chromatography and tandem mass spectrometry. Xu Y; Willson KJ; Musson DG J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb; 863(1):64-73. PubMed ID: 18255359 [TBL] [Abstract][Full Text] [Related]
15. Determination of benzodiazepines in ante-mortem and post-mortem whole blood by solid-supported liquid-liquid extraction and UPLC-MS/MS. Sauve EN; Langødegård M; Ekeberg D; Øiestad AM J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():177-88. PubMed ID: 22119506 [TBL] [Abstract][Full Text] [Related]
16. Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry. Xu Y; Du L; Soli ED; Braun MP; Dean DC; Musson DG J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Mar; 817(2):287-96. PubMed ID: 15686997 [TBL] [Abstract][Full Text] [Related]
17. Quantification of free sialic acid in human plasma through a robust quinoxalinone derivatization and LC-MS/MS using isotope-labeled standard calibration. Wang D; Zhou X; Wang L; Wang S; Sun XL J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jan; 944():75-81. PubMed ID: 24291723 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous determination of guanidinoacetate, creatine and creatinine in urine and plasma by un-derivatized liquid chromatography-tandem mass spectrometry. Carling RS; Hogg SL; Wood TC; Calvin J Ann Clin Biochem; 2008 Nov; 45(Pt 6):575-84. PubMed ID: 18782816 [TBL] [Abstract][Full Text] [Related]
19. Development and validation of a sensitive solid-phase-extraction (SPE) method using high-performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) for determination of risedronate concentrations in human plasma. Ghassabian S; Wright LA; Dejager AD; Smith MT J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jan; 881-882():34-41. PubMed ID: 22197608 [TBL] [Abstract][Full Text] [Related]
20. Development and validation of UHPLC-ESI-MS/MS method for the determination of selected cardiovascular drugs, polyphenols and their metabolites in human urine. Magiera S; Baranowska I; Kusa J Talanta; 2012 Jan; 89():47-56. PubMed ID: 22284458 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]