These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
141 related articles for article (PubMed ID: 23062639)
1. Comparison of clinical effects of au-pt based and ni-cr based porcelain crowns. Li-Chun W; Ye S; Teng M Chin Med Sci J; 2012 Sep; 27(3):167-70. PubMed ID: 23062639 [TBL] [Abstract][Full Text] [Related]
2. [Clinical evaluation of the effect of gold alloy and Ni-Cr alloy porcelain fused metal crown restorations]. Sun WG; Liu XH; Zhang L; Zhang C; Xie MY; Zhou WJ Shanghai Kou Qiang Yi Xue; 2009 Feb; 18(1):40-3. PubMed ID: 19290425 [TBL] [Abstract][Full Text] [Related]
3. [Effect of different porcelain-fused-to-metal crown inner metal materials on the level of soluble intercellular adhesion molecule-1 and interleukin-1beta in gingival crevicular fluid]. Yuan T; Zhang Y; Wu ZH Hua Xi Kou Qiang Yi Xue Za Zhi; 2011 Oct; 29(5):477-80. PubMed ID: 22165113 [TBL] [Abstract][Full Text] [Related]
4. [A study on the color difference between Au-Pt alloy porcelain and Ni-Cr alloy porcelain]. Li Y; Zhao Y; Li H Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Jun; 21(3):217-9. PubMed ID: 12898768 [TBL] [Abstract][Full Text] [Related]
5. [Comparison of the influences of gold alloy metal crown and ni-cr alloy metal crown on gingival health]. Hu YD; Wu XM; Yu HY; Ma TY Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2010 Jun; 32(3):269-71. PubMed ID: 20602876 [TBL] [Abstract][Full Text] [Related]
6. Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology. Huang Z; Zhang L; Zhu J; Zhang X J Prosthet Dent; 2015 Jun; 113(6):623-7. PubMed ID: 25794918 [TBL] [Abstract][Full Text] [Related]
7. Spectrophotometric evaluation of the optical influence of different metal alloys and porcelains in the metal-ceramic complex. Kourtis SG; Tripodakis AP; Doukoudakis AA J Prosthet Dent; 2004 Nov; 92(5):477-85. PubMed ID: 15523337 [TBL] [Abstract][Full Text] [Related]
8. The influence of metal substrates and porcelains on the shade of metal-ceramic complex: a spectrophotometric study. Janardanan K; Pillai ST; Karunakaran H Indian J Dent Res; 2012; 23(6):838. PubMed ID: 23649078 [TBL] [Abstract][Full Text] [Related]
9. Ceramic Defects in Metal-Ceramic Fixed Dental Prostheses Made from Co-Cr and Au-Pt Alloys: A Retrospective Study. Mikeli A; Boening KW; Lißke B Int J Prosthodont; 2015; 28(5):487-9. PubMed ID: 26340008 [TBL] [Abstract][Full Text] [Related]
10. The concentrations of IL-8 and IL-6 in gingival crevicular fluid during nickel-chromium alloy porcelain crown restoration. Yu L; Su J; Zou D; Mariano Z J Mater Sci Mater Med; 2013 Jul; 24(7):1717-22. PubMed ID: 23564008 [TBL] [Abstract][Full Text] [Related]
11. The effects of post-core and crown material and luting agents on stress distribution in tooth restorations. Oyar P J Prosthet Dent; 2014 Aug; 112(2):211-9. PubMed ID: 24560984 [TBL] [Abstract][Full Text] [Related]
12. Finite element analysis of stress distribution of 2 different tooth preparation designs in porcelain-fused-to-metal crowns. Oyar P; Ulusoy M; Eskitascioglu G Int J Prosthodont; 2006; 19(1):85-91. PubMed ID: 16479766 [TBL] [Abstract][Full Text] [Related]
13. Effect of electric arc, gas oxygen torch and induction melting techniques on the marginal accuracy of cast base-metal and noble metal-ceramic crowns. Gómez-Cogolludo P; Castillo-Oyagüe R; Lynch CD; Suárez-García MJ J Dent; 2013 Sep; 41(9):826-31. PubMed ID: 23810734 [TBL] [Abstract][Full Text] [Related]
14. Stress distribution in metal-ceramic crowns with a facial porcelain margin. Anusavice KJ; Hojjatie B J Dent Res; 1987 Sep; 66(9):1493-8. PubMed ID: 3305641 [TBL] [Abstract][Full Text] [Related]
15. Effect of metal design on marginal distortion of metal-ceramic crowns. DeHoff PH; Anusavice KJ J Dent Res; 1984 Nov; 63(11):1327-31. PubMed ID: 6389636 [TBL] [Abstract][Full Text] [Related]
16. [Short-term observation of gold-plating unprecious metal ceramic crown in restoring anterior tooth]. Shi YL; Mu YZ; Zhao N; Ge SH Shanghai Kou Qiang Yi Xue; 2005 Feb; 14(1):11-3. PubMed ID: 15747005 [TBL] [Abstract][Full Text] [Related]
17. Difference between selected and obtained shade for metal-ceramic crown systems. Omar H; Atta O; El-Mowafy O Oper Dent; 2008; 33(5):502-7. PubMed ID: 18833856 [TBL] [Abstract][Full Text] [Related]
18. A calculation of stress distribution in metal-porcelain crowns by using three-dimensional finite element method. Aykul H; Toparli M; Dalkiz M J Oral Rehabil; 2002 Apr; 29(4):381-6. PubMed ID: 11966973 [TBL] [Abstract][Full Text] [Related]
19. Urinary levels of nickel and chromium associated with dental restoration by nickel-chromium based alloys. Chen B; Xia G; Cao XM; Wang J; Xu BY; Huang P; Chen Y; Jiang QW Int J Oral Sci; 2013 Mar; 5(1):44-8. PubMed ID: 23579466 [TBL] [Abstract][Full Text] [Related]
20. Influence of metal thickness on stress distribution in metal-ceramic crowns. Anusavice KJ; Hojjatie B; Dehoff PH J Dent Res; 1986 Sep; 65(9):1173-8. PubMed ID: 3525630 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]