1. Balloon entrapment in a coronary artery: potential serious complications of balloon rupture. Colombo A; Skinner JM Cathet Cardiovasc Diagn; 1990 Jan; 19(1):23-5. PubMed ID: 2306760 [TBL] [Abstract][Full Text] [Related]
2. Pinhole balloon rupture during coronary angioplasty causing rupture of the coronary artery. LeMay MR; Beanlands DS Cathet Cardiovasc Diagn; 1990 Feb; 19(2):91-2. PubMed ID: 2306783 [TBL] [Abstract][Full Text] [Related]
3. Rupture and entrapment of a balloon catheter in the left anterior descending artery: fluoroscopic appearance of impending balloon failure. Kussmaul WG; Marzo K; Tomaszewski J; DiSesa VJ Cathet Cardiovasc Diagn; 1993 Mar; 28(3):256-9. PubMed ID: 8440008 [TBL] [Abstract][Full Text] [Related]
4. A two-case series of entrapment of a ruptured balloon in the coronary artery: Avoidable complications and nonsurgical management. Chang WT; Chen JY; Li YH; Tsai LM; Lee CH J Formos Med Assoc; 2015 Nov; 114(11):1135-9. PubMed ID: 23791003 [TBL] [Abstract][Full Text] [Related]
5. Circumferential rupture and entrapment of a balloon-on-a-wire device during coronary angioplasty. Nukta E; Meier B; Urban P; Muller T Cathet Cardiovasc Diagn; 1990 Jun; 20(2):123-5. PubMed ID: 2354512 [TBL] [Abstract][Full Text] [Related]
6. Removal of retained intracoronary percutaneous transluminal coronary angioplasty equipment by a percutaneous twin guidewire method. Gurley JC; Booth DC; Hixson C; Smith MD Cathet Cardiovasc Diagn; 1990 Apr; 19(4):251-6. PubMed ID: 2334959 [TBL] [Abstract][Full Text] [Related]
7. Retrieval of impacted broken balloon by balloon inflation in guiding catheter. Mehta V; Pandit BN; Yusuf J; Mukhopadhyay S; Trehan V; Tyagi S Cardiovasc Interv Ther; 2014 Jul; 29(3):252-5. PubMed ID: 24178859 [TBL] [Abstract][Full Text] [Related]
8. Proximal rupture and intracoronary entrapment of a rotating device during low-speed rotational coronary angioplasty. Juillière Y; Danchin N; Amrein D; Suty-Selton C; Cherrier F Cathet Cardiovasc Diagn; 1991 May; 23(1):34-6. PubMed ID: 1830828 [TBL] [Abstract][Full Text] [Related]
10. Entrapment of an angioplasty balloon catheter: a case report. Rizzo TF; Werres R; Ciccone J; Karanam R; Shah S Cathet Cardiovasc Diagn; 1988; 14(4):255-7. PubMed ID: 2969288 [TBL] [Abstract][Full Text] [Related]
11. Multiple balloon rupture during coronary angioplasty. A case report. Kwan T; Huber MS; Jani H; Feit A Angiology; 1994 Oct; 45(10):891-6. PubMed ID: 7943941 [TBL] [Abstract][Full Text] [Related]
12. [A case report of entrapment of PTCA balloon catheter caused by its rupture]. Nishiwaki N; Kawano Y; Furukawa K; Nakayama Y Nihon Kyobu Geka Gakkai Zasshi; 1991 Aug; 39(8):1226-30. PubMed ID: 1940531 [TBL] [Abstract][Full Text] [Related]
13. [Guide-wire rupture as a complication of coronary angioplasty. Apropos 2 cases and a review of the literature]. Ojeda Delgado JL; Jiménez Mena M; Barrios Alonso V; Pena Tizón J; Fernández Sánchez-Villarán E; Hernández Madrid A; Marín Huerta E; Pey Illera J Rev Esp Cardiol; 1992 Feb; 45(2):141-4. PubMed ID: 1561468 [TBL] [Abstract][Full Text] [Related]