These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 23070483)

  • 41. [Medical Applications of the PHITS Code I: Recent Improvements and Biological Dose Estimation Model].
    Sato T; Furuta T; Hashimoto S; Kuga N
    Igaku Butsuri; 2015; 35(2):180-7. PubMed ID: 26882708
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Patient-specific Extravasation Dosimetry Using Uptake Probe Measurements.
    Osborne D; Kiser JW; Knowland J; Townsend D; Fisher DR
    Health Phys; 2021 Mar; 120(3):339-343. PubMed ID: 33443961
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Skin dose calculations for uranium fuel particles below 500 microns in diameter.
    Pöllänen R; Toivonen H
    Health Phys; 1995 Mar; 68(3):401-5. PubMed ID: 7860313
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Calculating the peak skin dose resulting from fluoroscopically-guided interventions. Part II: case studies.
    Jones AK; Pasciak AS
    J Appl Clin Med Phys; 2012 Jan; 13(1):3693. PubMed ID: 22231220
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Reliability of measurement of skin ultrasonic properties in vivo: a potential technique for assessing irradiated skin.
    Huang YP; Zheng YP; Leung SF; Mak AF
    Skin Res Technol; 2007 Feb; 13(1):55-61. PubMed ID: 17250533
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Wavelength-dependent penetration depths of ultraviolet radiation in human skin.
    Meinhardt M; Krebs R; Anders A; Heinrich U; Tronnier H
    J Biomed Opt; 2008; 13(4):044030. PubMed ID: 19021357
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A modified geometric factor approach to internal gamma ray dosimetry.
    Gupta MM; Reddy AR; Gupta PC; Nagaratnam A
    Br J Radiol; 1976 Jan; 49(577):71-5. PubMed ID: 1276578
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Beta Skin Dosimetry using Passivated Planar Silicon Detector.
    Tchouaso MT; Miller WH
    Appl Radiat Isot; 2018 May; 135():99-103. PubMed ID: 29413843
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Effects of cellular fine structure on scattered light pattern.
    Liu C; Capjack CE
    IEEE Trans Nanobioscience; 2006 Jun; 5(2):76-82. PubMed ID: 16805102
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Light scattering spectroscopy of human skin in vivo.
    Zonios G; Dimou A
    Opt Express; 2009 Feb; 17(3):1256-67. PubMed ID: 19188953
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Effects of the tissue-air interface in calculations of beta-particle skin dose at a depth of 70 microns.
    Crawford OH; Turner JE; Hamm RN; Ashley JC
    Health Phys; 1991 Nov; 61(5):641-5. PubMed ID: 1752748
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The dosimetry of beta sources in tissue; the point-source function.
    LOEVINGER R
    Radiology; 1956 Jan; 66(1):55-62. PubMed ID: 13280895
    [No Abstract]   [Full Text] [Related]  

  • 53. Rapid dissemination of light transport models on the web.
    Baranoski GV; Dimson T; Chen TF; Kimmel B; Yim D; Miranda E
    IEEE Comput Graph Appl; 2012; 32(3):10-5. PubMed ID: 24805997
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Validation of the photon dose calculation model in the VARSKIN 4 skin dose computer code.
    Sherbini S; Decicco J; Struckmeyer R; Saba M; Bush-Goddard S
    Health Phys; 2012 Dec; 103(6):763-9. PubMed ID: 23111523
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Verification of the VARSKIN beta skin dose calculation computer code.
    Sherbini S; DeCicco J; Gray AT; Struckmeyer R
    Health Phys; 2008 Jun; 94(6):527-38. PubMed ID: 18469586
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A comparison of cellular irradiation techniques with alpha particles using the Geant4 Monte Carlo simulation toolkit.
    Incerti S; Gault N; Habchi C; Lefaix JL; Moretto P; Poncy JL; Pouthier T; Seznec H
    Radiat Prot Dosimetry; 2006; 122(1-4):327-9. PubMed ID: 17132663
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The new VARSKIN 4 photon skin dosimetry model.
    Hamby DM; Lodwick CJ; Palmer TS; Reese SR; Higley KA; Caffrey JA; Sherbini S; Saba M; Bush-Goddard SP
    Radiat Prot Dosimetry; 2013; 154(3):356-63. PubMed ID: 23070483
    [TBL] [Abstract][Full Text] [Related]  

  • 58. PERFORMANCE OF THE VARSKIN 5 (v5.3) ELECTRON DOSIMETRY MODEL.
    Anspach LJ; Hamby DM
    Radiat Prot Dosimetry; 2018 Oct; 181(2):111-119. PubMed ID: 29378064
    [TBL] [Abstract][Full Text] [Related]  

  • 59.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 60.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.