These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 23073534)

  • 1. Speckle tracking echocardiography derived systolic longitudinal strain is better than rest single photon emission tomography perfusion imaging for nonviable myocardium identification.
    Hutyra M; Skala T; Kaminek M; Horak D; Kocher M; Tudos Z; Jarkovsky J; Precek J; Taborsky M
    Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2013 Mar; 157(1):12-21. PubMed ID: 23073534
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of echocardiographic two-dimensional speckle tracking longitudinal strain imaging for viability assessment in patients with chronic ischemic left ventricular dysfunction and comparison with contrast-enhanced magnetic resonance imaging.
    Roes SD; Mollema SA; Lamb HJ; van der Wall EE; de Roos A; Bax JJ
    Am J Cardiol; 2009 Aug; 104(3):312-7. PubMed ID: 19616660
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Myocardial deformation imaging by two-dimensional speckle-tracking echocardiography for prediction of global and segmental functional changes after acute myocardial infarction: a comparison with late gadolinium enhancement cardiac magnetic resonance.
    Altiok E; Tiemann S; Becker M; Koos R; Zwicker C; Schroeder J; Kraemer N; Schoth F; Adam D; Friedman Z; Marx N; Hoffmann R
    J Am Soc Echocardiogr; 2014 Mar; 27(3):249-57. PubMed ID: 24368027
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Global and regional longitudinal strain assessed by two-dimensional speckle tracking echocardiography identifies early myocardial dysfunction and transmural extent of myocardial scar in patients with acute ST elevation myocardial infarction and relatively preserved LV function.
    Cimino S; Canali E; Petronilli V; Cicogna F; De Luca L; Francone M; Sardella G; Iacoboni C; Agati L
    Eur Heart J Cardiovasc Imaging; 2013 Aug; 14(8):805-11. PubMed ID: 23258316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of myocardial viability at dobutamine echocardiography by deformation analysis using tissue velocity and speckle-tracking.
    Bansal M; Jeffriess L; Leano R; Mundy J; Marwick TH
    JACC Cardiovasc Imaging; 2010 Feb; 3(2):121-31. PubMed ID: 20159637
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of myocardial viability with contrast-enhanced magnetic resonance imaging and comparison with single-photon emission computed tomography.
    Wang YN; Jin ZY; Zhang ZH; Kong LY; Chen LB; Zhou L; Sun HY; Zhang H; Miao Q
    Chin Med Sci J; 2006 Dec; 21(4):239-44. PubMed ID: 17249199
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Utility of speckle tracking echocardiography to characterize dysfunctional myocardium in patients with ischemic cardiomyopathy referred for cardiac resynchronization therapy.
    Kydd AC; Khan F; Gopalan D; Ring L; Rana BS; Virdee MS; Dutka DP
    Echocardiography; 2014 Jul; 31(6):736-43. PubMed ID: 24303794
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Non-invasive detection of ischemic left ventricular dysfunction using rest gated SPECT: expectation of simultaneous evaluation of both myocardial perfusion and wall motion abnormality.
    Maeba H; Takehana K; Nakamura S; Yoshida S; Ueyama T; Hatada K; Iwasaka T
    Ann Nucl Med; 2008 May; 22(4):309-16. PubMed ID: 18535882
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correlation of preoperative myocardial function, perfusion, and metabolism with postoperative function at rest and stress after bypass surgery in severe left ventricular dysfunction.
    Pasquet A; Williams MJ; Secknus MA; Zuchowski C; Lytle BW; Marwick TH
    Am J Cardiol; 1999 Jul; 84(1):58-64. PubMed ID: 10404852
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Parametric quantification of myocardial ischaemia using real-time perfusion adenosine stress echocardiography images, with SPECT as reference method.
    Gudmundsson P; Shahgaldi K; Winter R; Dencker M; Kitlinski M; Thorsson O; Ljunggren L; Willenheimer R
    Clin Physiol Funct Imaging; 2010 Jan; 30(1):30-42. PubMed ID: 20089074
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Myocardial viability in chronic ischemic heart disease: comparison of delayed-enhancement magnetic resonance imaging with 99mTc-sestamibi and 18F-fluorodeoxyglucose single-photon emission computed tomography.
    Liu Q; Zhao S; Yan C; Lu M; Jiang S; Zhang Y; Li S; Liu Y; Yang M; He Z
    Nucl Med Commun; 2009 Aug; 30(8):610-6. PubMed ID: 19491715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low-dose dobutamine electrocardiograph-gated myocardial SPECT for identifying viable myocardium: comparison with dobutamine stress echocardiography and PET.
    Yoshinaga K; Morita K; Yamada S; Komuro K; Katoh C; Ito Y; Kuge Y; Kohya T; Kitabatake A; Tamaki N
    J Nucl Med; 2001 Jun; 42(6):838-44. PubMed ID: 11390545
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Systolic and diastolic left ventricle function assessment by tissue Doppler echocardiography in patients with perfusion defects in SPECT study].
    Kostkiewicz M; Płazak W; Tracz W; Olszowska M; Pieniazek P
    Przegl Lek; 2005; 62(12):1362-6. PubMed ID: 16786749
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Evaluation of myocardial viability with contrast-enhanced magnetic resonance imaging--comparison of the late enhancement technique with positronemission tomography].
    Hunold P; Brandt-Mainz K; Freudenberg L; Vogt FM; Neumann T; Knipp S; Barkhausen J
    Rofo; 2002 Jul; 174(7):867-73. PubMed ID: 12101477
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Global Longitudinal Strain at Rest for Detection of Coronary Artery Disease in Patients without Diabetes Mellitus.
    Zuo HJ; Yang XT; Liu QG; Zhang Y; Zeng HS; Yan JT; Wang DW; Wang H
    Curr Med Sci; 2018 Jun; 38(3):413-421. PubMed ID: 30074206
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Doppler tissue velocity sampling improves diagnostic accuracy during dobutamine stress echocardiography for the assessment of viable myocardium in patients with severe left ventricular dysfunction.
    Rambaldi R; Poldermans D; Bax JJ; Boersma E; Elhendy A; Vletter W; Roelandt JR; Valkema R
    Eur Heart J; 2000 Jul; 21(13):1091-8. PubMed ID: 10843827
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Head-to-head comparison of exercise-redistribution-reinjection thallium single-photon emission computed tomography and low dose dobutamine echocardiography for prediction of reversibility of chronic left ventricular ischemic dysfunction.
    Vanoverschelde JL; D'Hondt AM; Marwick T; Gerber BL; De Kock M; Dion R; Wijns W; Melin JA
    J Am Coll Cardiol; 1996 Aug; 28(2):432-42. PubMed ID: 8800122
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetic resonance imaging in determination of myocardial ischemia and viability: comparison with positron emission tomography and single-photon emission computed tomography in a porcine model.
    Wang L; Zhu HY; Tian JM; Huang SD; Kong LS; Lu JP
    Acta Radiol; 2007 Jun; 48(5):500-7. PubMed ID: 17520425
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Head-to-head comparison of contrast-enhanced cardiovascular magnetic resonance and ²⁰¹Thallium single photon emission computed tomography for prediction of reversible left ventricular dysfunction in chronic ischaemic heart disease.
    Regenfus M; Schlundt C; von Erffa J; Schmidt M; Reulbach U; Kuwert T; Daniel WG; Schmid M
    Int J Cardiovasc Imaging; 2012 Aug; 28(6):1427-34. PubMed ID: 21874571
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of myocardial viability in patients with acute myocardial infarction by two-dimensional speckle tracking echocardiography combined with low-dose dobutamine stress echocardiography.
    Gong L; Li D; Chen J; Wang X; Xu T; Li W; Ren S; Wang C
    Int J Cardiovasc Imaging; 2013 Jun; 29(5):1017-28. PubMed ID: 23358919
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.