These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 23073838)

  • 1. Stability of plasma electrolytic oxidation coating on titanium in artificial saliva.
    Matykina E; Arrabal R; Mohedano M; Pardo A; Merino MC; Rivero E
    J Mater Sci Mater Med; 2013 Jan; 24(1):37-51. PubMed ID: 23073838
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bioactive plasma electrolytic oxidation coatings--the role of the composition, microstructure, and electrochemical stability.
    Mohedano M; Guzman R; Arrabal R; López Lacomba JL; Matykina E
    J Biomed Mater Res B Appl Biomater; 2013 Nov; 101(8):1524-37. PubMed ID: 23744783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Production of a biofunctional titanium surface using plasma electrolytic oxidation and glow-discharge plasma for biomedical applications.
    Beline T; Marques Ida S; Matos AO; Ogawa ES; Ricomini-Filho AP; Rangel EC; da Cruz NC; Sukotjo C; Mathew MT; Landers R; Consani RL; Mesquita MF; Barão VA
    Biointerphases; 2016 Mar; 11(1):011013. PubMed ID: 26984234
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal release from ceramic coatings for dental implants.
    Mohedano M; Matykina E; Arrabal R; Pardo A; Merino MC
    Dent Mater; 2014 Mar; 30(3):e28-40. PubMed ID: 24438823
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioactive multi-elemental PEO-coatings on titanium for dental implant applications.
    Santos-Coquillat A; Mohedano M; Martinez-Campos E; Arrabal R; Pardo A; Matykina E
    Mater Sci Eng C Mater Biol Appl; 2019 Apr; 97():738-752. PubMed ID: 30678963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of plasma nitriding and titanium nitride coating on the corrosion resistance of titanium.
    Wang X; Bai S; Li F; Li D; Zhang J; Tian M; Zhang Q; Tong Y; Zhang Z; Wang G; Guo T; Ma C
    J Prosthet Dent; 2016 Sep; 116(3):450-6. PubMed ID: 27061632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface characterization and corrosion behavior of calcium phosphate-base composite layer on titanium and its alloys via plasma electrolytic oxidation: A review paper.
    Rafieerad AR; Ashra MR; Mahmoodian R; Bushroa AR
    Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():397-413. PubMed ID: 26354281
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Corrosion resistance of casted titanium by compound treatments in the artificial saliva with different fluoride concentrations].
    Wang XL; Guo TW
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2012 Sep; 47(9):557-61. PubMed ID: 23141732
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Synthesis of bioactive glass-based coating by plasma electrolytic oxidation: Untangling a new deposition pathway toward titanium implant surfaces.
    Costa RC; Souza JGS; Cordeiro JM; Bertolini M; de Avila ED; Landers R; Rangel EC; Fortulan CA; Retamal-Valdes B; da Cruz NC; Feres M; Barão VAR
    J Colloid Interface Sci; 2020 Nov; 579():680-698. PubMed ID: 32652323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bioactivity Performance of Pure Mg after Plasma Electrolytic Oxidation in Silicate-Based Solutions.
    Husak Y; Michalska J; Oleshko O; Korniienko V; Grundsteins K; Dryhval B; Altundal S; Mishchenko O; Viter R; Pogorielov M; Simka W
    Molecules; 2021 Apr; 26(7):. PubMed ID: 33917454
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Stress and electrochemical corrosion of titanium produced by laser rapid forming].
    Zhu JF; Gan K; Du TF; Gao B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Apr; 54(4):257-262. PubMed ID: 30955298
    [No Abstract]   [Full Text] [Related]  

  • 12. Effect of Ag on the corrosion behavior of Ti-Ag alloys in artificial saliva solutions.
    Zhang BB; Zheng YF; Liu Y
    Dent Mater; 2009 May; 25(5):672-7. PubMed ID: 19150734
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro biological response of plasma electrolytically oxidized and plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V alloy.
    Yeung WK; Reilly GC; Matthews A; Yerokhin A
    J Biomed Mater Res B Appl Biomater; 2013 Aug; 101(6):939-49. PubMed ID: 23529912
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hierarchically porous surface of HA-sandblasted Ti implant screw using the plasma electrolytic oxidation: Physical characterization and biological responses.
    Choe Y; Li CJ; Yeo DH; Kim YJ; Lee JH; Lee HH
    J Biomater Appl; 2024 May; 38(10):1100-1117. PubMed ID: 38580320
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term assessment of the implant titanium material--artificial saliva interface.
    Popa MV; Vasilescu E; Drob P; Vasilescu C; Demetrescu I; Ionita D
    J Mater Sci Mater Med; 2008 Jan; 19(1):1-9. PubMed ID: 17990081
    [TBL] [Abstract][Full Text] [Related]  

  • 16. UV-photofunctionalization of a biomimetic coating for dental implants application.
    Dini C; Nagay BE; Cordeiro JM; da Cruz NC; Rangel EC; Ricomini-Filho AP; de Avila ED; Barão VAR
    Mater Sci Eng C Mater Biol Appl; 2020 May; 110():110657. PubMed ID: 32204085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of fluoride ions on the corrosion behaviour of Ti metal, and Ti6-Al-7Nb and Ti-6Al-4V alloys in artificial saliva.
    Milošev I; Kapun B; Selih VS
    Acta Chim Slov; 2013; 60(3):543-55. PubMed ID: 24169708
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of solution pH and electrical parameters on hydroxyapatite coatings deposited by a plasma-assisted electrophoresis technique.
    Nie X; Leyland A; Matthews A; Jiang JC; Meletis EI
    J Biomed Mater Res; 2001 Dec; 57(4):612-8. PubMed ID: 11553892
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ion release from NiTi orthodontic wires in artificial saliva with various acidities.
    Huang HH; Chiu YH; Lee TH; Wu SC; Yang HW; Su KH; Hsu CC
    Biomaterials; 2003 Sep; 24(20):3585-92. PubMed ID: 12809787
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro degradation behavior and cytocompatibility of biodegradable AZ31 alloy with PEO/HT composite coating.
    Tian P; Liu X; Ding C
    Colloids Surf B Biointerfaces; 2015 Apr; 128():44-54. PubMed ID: 25731092
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.