BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 2307923)

  • 1. The role of experience in clinical accuracy.
    Mior SA; McGregor M; Schut B
    J Manipulative Physiol Ther; 1990 Feb; 13(2):68-71. PubMed ID: 2307923
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of motion palpation procedures to detect sacroiliac joint fixations.
    Herzog W; Read LJ; Conway PJ; Shaw LD; McEwen MC
    J Manipulative Physiol Ther; 1989 Apr; 12(2):86-92. PubMed ID: 2715742
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interexaminer reliability of a leg length analysis procedure among novice and experienced practitioners.
    Holt KR; Russell DG; Hoffmann NJ; Bruce BI; Bushell PM; Taylor HH
    J Manipulative Physiol Ther; 2009; 32(3):216-22. PubMed ID: 19362232
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A review of intraexaminer and interexaminer reliability of static spinal palpation: a literature synthesis.
    Haneline MT; Young M
    J Manipulative Physiol Ther; 2009 Jun; 32(5):379-86. PubMed ID: 19539121
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intra- and interobserver reliability of passive motion palpation of the lumbar spine.
    Mootz RD; Keating JC; Kontz HP; Milus TB; Jacobs GE
    J Manipulative Physiol Ther; 1989 Dec; 12(6):440-5. PubMed ID: 2628523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality: Part II.
    Boline PD; Haas M; Meyer JJ; Kassak K; Nelson C; Keating JC
    J Manipulative Physiol Ther; 1993; 16(6):363-74. PubMed ID: 8409784
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inter- and intra-examiner reliability of single and composites of selected motion palpation and pain provocation tests for sacroiliac joint.
    Arab AM; Abdollahi I; Joghataei MT; Golafshani Z; Kazemnejad A
    Man Ther; 2009 Apr; 14(2):213-21. PubMed ID: 18373938
    [TBL] [Abstract][Full Text] [Related]  

  • 8. PulStar differential compliance spinal instrument: a randomized interexaminer and intraexaminer reliability study.
    Leach RA; Parker PL; Veal PS
    J Manipulative Physiol Ther; 2003 Oct; 26(8):493-501. PubMed ID: 14569215
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spinal palpation for lumbar segmental mobility and pain provocation: an interexaminer reliability study.
    Schneider M; Erhard R; Brach J; Tellin W; Imbarlina F; Delitto A
    J Manipulative Physiol Ther; 2008; 31(6):465-73. PubMed ID: 18722203
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of chiropractic methods commonly used to detect manipulable lesions in patients with chronic low-back pain.
    French SD; Green S; Forbes A
    J Manipulative Physiol Ther; 2000 May; 23(4):231-8. PubMed ID: 10820295
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inter-examiner and intra-examiner agreement for assessing sacroiliac anatomical landmarks using palpation and observation: pilot study.
    O'Haire C; Gibbons P
    Man Ther; 2000 Feb; 5(1):13-20. PubMed ID: 10688955
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reliability of manual skinfold tests in a healthy male population.
    Rouwmaat PH; Everaert D; Stappaerts KH; Aufdemkampe G
    J Manipulative Physiol Ther; 1998 Jun; 21(5):327-32. PubMed ID: 9627863
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The reliability of lumbar motion palpation.
    Panzer DM
    J Manipulative Physiol Ther; 1992 Oct; 15(8):518-24. PubMed ID: 1402412
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality.
    Keating JC; Bergmann TF; Jacobs GE; Finer BA; Larson K
    J Manipulative Physiol Ther; 1990 Oct; 13(8):463-70. PubMed ID: 2146357
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The reliability of measuring active and passive cervical range of motion: an observer-blinded and randomized repeated-measures design.
    Christensen HW; Nilsson N
    J Manipulative Physiol Ther; 1998 Jun; 21(5):341-7. PubMed ID: 9627865
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Is there a difference in the reliable measurement of temporomandibular disorder signs between experienced and inexperienced examiners?
    Leher A; Graf K; PhoDuc JM; Rammelsberg P
    J Orofac Pain; 2005; 19(1):58-64. PubMed ID: 15779540
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The inter- and intraexaminer reliability of a paraspinal skin temperature differential instrument.
    Plaugher G; Lopes MA; Melch PE; Cremata EE
    J Manipulative Physiol Ther; 1991; 14(6):361-7. PubMed ID: 1919373
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interexaminer reliability of three methods of combining test results to determine side of sacral restriction, sacral base position, and innominate bone position.
    Tong HC; Heyman OG; Lado DA; Isser MM
    J Am Osteopath Assoc; 2006 Aug; 106(8):464-8. PubMed ID: 16943516
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The reliability of selected motion- and pain provocation tests for the sacroiliac joint.
    Robinson HS; Brox JI; Robinson R; Bjelland E; Solem S; Telje T
    Man Ther; 2007 Feb; 12(1):72-9. PubMed ID: 16843031
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inter- and intra-examiner reliability of palpation for sacroiliac joint dysfunction.
    Carmichael JP
    J Manipulative Physiol Ther; 1987 Aug; 10(4):164-71. PubMed ID: 3655566
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.