21. The importance of calibration method in determining the association between central blood pressure with left ventricular and left atrial strain. Ramkumar S; Yang H; Nolan M; Negishi T; Sharman JE; Marwick TH; Negishi K Int J Cardiovasc Imaging; 2022 Mar; 38(3):589-600. PubMed ID: 34676490 [TBL] [Abstract][Full Text] [Related]
22. Invasive validation of a novel brachial cuff-based oscillometric device (SphygmoCor XCEL) for measuring central blood pressure. Shoji T; Nakagomi A; Okada S; Ohno Y; Kobayashi Y J Hypertens; 2017 Jan; 35(1):69-75. PubMed ID: 27763994 [TBL] [Abstract][Full Text] [Related]
23. Comparison of two noninvasive devices for measurement of central systolic blood pressure with invasive measurement during cardiac catheterization. Ott C; Haetinger S; Schneider MP; Pauschinger M; Schmieder RE J Clin Hypertens (Greenwich); 2012 Sep; 14(9):575-9. PubMed ID: 22947354 [TBL] [Abstract][Full Text] [Related]
24. Accuracy of fully automated oscillometric central aortic blood pressure measurement techniques. Gotzmann M; Hogeweg M; Seibert FS; Rohn BJ; Bergbauer M; Babel N; Bauer F; Mügge A; Westhoff TH J Hypertens; 2020 Feb; 38(2):235-242. PubMed ID: 31503132 [TBL] [Abstract][Full Text] [Related]
25. Transmission of calibration errors (input) by generalized transfer functions to the aortic pressures (output) at different hemodynamic states. Papaioannou TG; Lekakis JP; Karatzis EN; Papamichael CM; Stamatelopoulos KS; Protogerou AD; Mavrikakis M; Stefanadis C Int J Cardiol; 2006 Jun; 110(1):46-52. PubMed ID: 16229910 [TBL] [Abstract][Full Text] [Related]
26. Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device. Weiss W; Gohlisch C; Harsch-Gladisch C; Tölle M; Zidek W; van der Giet M Blood Press Monit; 2012 Jun; 17(3):128-31. PubMed ID: 22561735 [TBL] [Abstract][Full Text] [Related]
27. Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies. Papaioannou TG; Karageorgopoulou TD; Sergentanis TN; Protogerou AD; Psaltopoulou T; Sharman JE; Weber T; Blacher J; Daskalopoulou SS; Wassertheurer S; Khir AW; Vlachopoulos C; Stergiopulos N; Stefanadis C; Nichols WW; Tousoulis D J Hypertens; 2016 Jul; 34(7):1237-48. PubMed ID: 27136312 [TBL] [Abstract][Full Text] [Related]
28. Calibration mode influences central blood pressure differences between SphygmoCor and two newer devices, the Arteriograph and Omron HEM-9000. Rezai MR; Goudot G; Winters C; Finn JD; Wu FC; Cruickshank JK Hypertens Res; 2011 Sep; 34(9):1046-51. PubMed ID: 21753770 [TBL] [Abstract][Full Text] [Related]
29. Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure. Climie RE; Schultz MG; Nikolic SB; Ahuja KD; Fell JW; Sharman JE Am J Hypertens; 2012 Apr; 25(4):414-20. PubMed ID: 22223041 [TBL] [Abstract][Full Text] [Related]
30. Central blood pressure assessment using oscillometry is feasible for everyday clinical practice. Reshetnik A; Gohlisch C; Zidek W; Tölle M; van der Giet M J Hum Hypertens; 2016 Dec; 30(12):737-741. PubMed ID: 27121445 [TBL] [Abstract][Full Text] [Related]
31. Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method. Cheng HM; Sung SH; Shih YT; Chuang SY; Yu WC; Chen CH Am J Hypertens; 2012 Nov; 25(11):1162-9. PubMed ID: 22874891 [TBL] [Abstract][Full Text] [Related]
32. Central aortic blood pressure from ultrasound wall-tracking of the carotid artery in children: comparison with invasive measurements and radial tonometry. Milne L; Keehn L; Guilcher A; Reidy JF; Karunanithy N; Rosenthal E; Qureshi S; Chowienczyk PJ; Sinha MD Hypertension; 2015 May; 65(5):1141-6. PubMed ID: 25824246 [TBL] [Abstract][Full Text] [Related]
33. Impact of arterial location, pressure wave indicators, and measurement devices on arterial form factor and mean and central arterial pressure. Izzo JL; Mukhopadhyay D; Nagpal S; Osmond P J Hum Hypertens; 2023 Oct; 37(10):891-897. PubMed ID: 36494516 [TBL] [Abstract][Full Text] [Related]
34. Estimating central systolic blood pressure during oscillometric determination of blood pressure: proof of concept and validation by comparison with intra-aortic pressure recording and arterial tonometry. Brett SE; Guilcher A; Clapp B; Chowienczyk P Blood Press Monit; 2012 Jun; 17(3):132-6. PubMed ID: 22466804 [TBL] [Abstract][Full Text] [Related]
35. Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. Ding FH; Fan WX; Zhang RY; Zhang Q; Li Y; Wang JG Am J Hypertens; 2011 Dec; 24(12):1306-11. PubMed ID: 21976274 [TBL] [Abstract][Full Text] [Related]
36. Methodological evaluation of the noninvasive estimation of central systolic blood pressure in nontreated patients: the Bogalusa Heart Study. Fernandez C; Hsu R; Sander G; Hussain A; Barshop R; Li S; Shu T; Zhang T; Galazka P; Chen W; Bazzano L; Giles TD Blood Press Monit; 2017 Apr; 22(2):95-100. PubMed ID: 27902495 [TBL] [Abstract][Full Text] [Related]
37. Comparison of the SphygmoCor and Omron devices in the estimation of pressure amplification against the invasive catheter measurement. Ding FH; Li Y; Zhang RY; Zhang Q; Wang JG J Hypertens; 2013 Jan; 31(1):86-93. PubMed ID: 23188416 [TBL] [Abstract][Full Text] [Related]
38. Estimation of central blood pressure waveform from femoral blood pressure waveform by blind sources separation. Gbaoui L; Hoeschen C; Kaniusas E; Khatib S; Gretschel S; Wellnhofer E Front Cardiovasc Med; 2023; 10():1280899. PubMed ID: 38045918 [TBL] [Abstract][Full Text] [Related]
39. Validation of a new piezoelectric device for noninvasive measurement of central aortic systolic blood pressure. Cuffaro PE; Morales MS; Barochiner J; Rada MA; Alfie J; Aparicio LS; Galarza CR; Micali RG; Marin MJ; Waisman GD Blood Press Monit; 2018 Feb; 23(1):49-51. PubMed ID: 29084016 [TBL] [Abstract][Full Text] [Related]
40. The accuracy of central SBP determined from the second systolic peak of the peripheral pressure waveform. Hickson SS; Butlin M; Mir FA; Graggaber J; Cheriyan J; Khan F; Grace AA; Yasmin ; Cockcroft JR; Wilkinson IB; McEniery CM; J Hypertens; 2009 Sep; 27(9):1784-8. PubMed ID: 19702000 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]