BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 23079763)

  • 1. Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications.
    Komarov S; Yin Y; Wu H; Wen J; Krawczynski H; Meng LJ; Tai YC
    Phys Med Biol; 2012 Nov; 57(22):7355-80. PubMed ID: 23079763
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo investigation of charge-transport effects on energy resolution and detection efficiency of pixelated CZT detectors for SPECT/PET applications.
    Myronakis ME; Darambara DG
    Med Phys; 2011 Jan; 38(1):455-67. PubMed ID: 21361214
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 3-D Spatial Resolution of 350
    Yin Y; Chen X; Wu H; Komarov S; Garson A; Li Q; Guo Q; Krawczynski H; Meng LJ; Tai YC
    IEEE Trans Nucl Sci; 2013 Feb; 60(1):9-15. PubMed ID: 28250476
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Charge Sharing and Charge Loss in High-Flux Capable Pixelated CdZnTe Detectors.
    Koch-Mehrin KAL; Bugby SL; Lees JE; Veale MC; Wilson MD
    Sensors (Basel); 2021 May; 21(9):. PubMed ID: 34066764
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing timing performance of CdTe detectors for PET.
    Nakhostin M
    Phys Med Biol; 2017 Sep; 62(19):N485-N505. PubMed ID: 28809758
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Study of electrode pattern design for a CZT-based PET detector.
    Gu Y; Levin CS
    Phys Med Biol; 2014 Jun; 59(11):2599-621. PubMed ID: 24786208
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simulation of a high-resolution cadmium zinc telluride positron emission tomography system.
    Stanford-Hill R; Groll A; Levin CS
    Med Phys; 2024 Feb; 51(2):1340-1350. PubMed ID: 38100261
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of a sub-assembly of 3D position sensitive cadmium zinc telluride detectors and electronics from a sub-millimeter resolution PET system.
    Abbaszadeh S; Gu Y; Reynolds PD; Levin CS
    Phys Med Biol; 2016 Sep; 61(18):6733-6753. PubMed ID: 27551981
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.
    Gu Y; Matteson JL; Skelton RT; Deal AC; Stephan EA; Duttweiler F; Gasaway TM; Levin CS
    Phys Med Biol; 2011 Mar; 56(6):1563-84. PubMed ID: 21335649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.
    Shikhaliev PM; Fritz SG; Chapman JW
    Med Phys; 2009 Nov; 36(11):5107-19. PubMed ID: 19994521
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A sub-millimeter resolution PET detector module using a multi-pixel photon counter array.
    Song TY; Wu H; Komarov S; Siegel SB; Tai YC
    Phys Med Biol; 2010 May; 55(9):2573-87. PubMed ID: 20393236
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance simulation of an x-ray detector for spectral CT with combined Si and Cd[Zn]Te detection layers.
    Herrmann C; Engel KJ; Wiegert J
    Phys Med Biol; 2010 Dec; 55(24):7697-713. PubMed ID: 21113093
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.
    Barber WC; Wessel JC; Nygard E; Iwanczyk JS
    Nucl Instrum Methods Phys Res A; 2015 Jun; 784():531-537. PubMed ID: 25937684
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors.
    Peng H; Levin CS
    Phys Med Biol; 2010 May; 55(9):2761-88. PubMed ID: 20400807
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera.
    Abe A; Takahashi N; Lee J; Oka T; Shizukuishi K; Kikuchi T; Inoue T; Jimbo M; Ryuo H; Bickel C
    Eur J Nucl Med Mol Imaging; 2003 Jun; 30(6):805-11. PubMed ID: 12677308
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system.
    Guerra P; Santos A; Darambara DG
    Phys Med Biol; 2008 Feb; 53(4):1099-113. PubMed ID: 18263961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spectral resolution and high-flux capability tradeoffs in CdTe detectors for clinical CT.
    Hsieh SS; Rajbhandary PL; Pelc NJ
    Med Phys; 2018 Apr; 45(4):1433-1443. PubMed ID: 29418004
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.
    Abbene L; Principato F; Gerardi G; Bettelli M; Seller P; Veale MC; Zambelli N; Benassi G; Zappettini A
    J Synchrotron Radiat; 2018 Jan; 25(Pt 1):257-271. PubMed ID: 29271775
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.