These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 23085200)

  • 21. All-inside meniscal repair devices compared with their matched inside-out vertical mattress suture repair: introducing 10,000 and 100,000 loading cycles.
    Rosso C; Müller S; Buckland DM; Schwenk T; Zimmermann S; de Wild M; Valderrabano V
    Am J Sports Med; 2014 Sep; 42(9):2226-33. PubMed ID: 24966304
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows.
    Borden P; Nyland J; Caborn DN; Pienkowski D
    Am J Sports Med; 2003; 31(3):374-8. PubMed ID: 12750129
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.
    Barber FA; Herbert MA; Schroeder FA; Aziz-Jacobo J; Sutker MJ
    Arthroscopy; 2009 Sep; 25(9):959-67. PubMed ID: 19732633
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of all-inside meniscal repair devices with matched inside-out suture repair.
    Rosso C; Kovtun K; Dow W; McKenzie B; Nazarian A; DeAngelis JP; Ramappa AJ
    Am J Sports Med; 2011 Dec; 39(12):2634-9. PubMed ID: 21997730
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical comparison of tibial eminence fracture fixation with high-strength suture, EndoButton, and suture anchor.
    Hapa O; Barber FA; Süner G; Özden R; Davul S; Bozdağ E; Sünbüloğlu E
    Arthroscopy; 2012 May; 28(5):681-7. PubMed ID: 22284410
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical comparison between suture anchor and transtibial pull-out repair for posterior medial meniscus root tears.
    Feucht MJ; Grande E; Brunhuber J; Rosenstiel N; Burgkart R; Imhoff AB; Braun S
    Am J Sports Med; 2014 Jan; 42(1):187-93. PubMed ID: 24018976
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Effect of various suture strength factors on behavior of meniscus sutures in cyclic loading conditions].
    Seil R; Rupp S; Jurecka C; Rein R; Kohn D
    Unfallchirurg; 2001 May; 104(5):392-8. PubMed ID: 11413954
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical evaluation of an all-inside suture-based device for repairing longitudinal meniscal tears.
    Masoudi A; Beamer BS; Harlow ER; Manoukian OS; Walley KC; Hertz B; Haeussler C; Olson JJ; Zurakowski D; Nazarian A; Ramappa AJ; DeAngelis JP
    Arthroscopy; 2015 Mar; 31(3):428-34. PubMed ID: 25442653
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Biomechanical study on different high-strength sutures and suture site for repairing posterior root tear of the medial meniscus].
    Wang JT; Bu JL; Shen XZ; Chang H; Teng LJ; Zhu JL; Liu Y; Liu Y
    Zhongguo Gu Shang; 2021 May; 34(5):442-7. PubMed ID: 34032046
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Strength of Transosseous Medial Meniscal Root Repair Using a Simple Suture Technique Is Dependent on Suture Material and Position.
    Robinson JR; Frank EG; Hunter AJ; Jermin PJ; Gill HS
    Am J Sports Med; 2018 Mar; 46(4):924-932. PubMed ID: 29364699
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tibiofemoral Contact Mechanics After Horizontal or Ripstop Suture in Inside-Out and Transtibial Repair for Meniscus Radial Tears in a Porcine Model.
    Zhang HZ; Zhou YF; Li WP; Luo H; Wu JT; Jiang C; Chen Z; Hou JY; Yang R; Song B; Zhang ZZ
    Arthroscopy; 2021 Mar; 37(3):932-940.e2. PubMed ID: 33227321
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cyclic testing of meniscal sutures.
    Seil R; Rupp S; Kohn DM
    Arthroscopy; 2000; 16(5):505-10. PubMed ID: 10882446
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Primary Fixation and Cyclic Performance of Single-Stitch All-Inside and Inside-Out Meniscal Devices for Repairing Vertical Longitudinal Meniscal Tears.
    Bachmaier S; Krych AJ; Smith PA; Herbort M; Ritter D; LaPrade RF; Wijdicks CA
    Am J Sports Med; 2022 Aug; 50(10):2705-2713. PubMed ID: 35787211
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: biomechanical evaluation of new meniscus refixation systems.
    Zantop T; Eggers AK; Weimann A; Hassenpflug J; Petersen W
    Am J Sports Med; 2004 Jun; 32(4):863-9. PubMed ID: 15150031
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biomechanical evaluation of a transtibial pull-out meniscal root repair: challenging the bungee effect.
    Cerminara AJ; LaPrade CM; Smith SD; Ellman MB; Wijdicks CA; LaPrade RF
    Am J Sports Med; 2014 Dec; 42(12):2988-95. PubMed ID: 25239930
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus.
    Becker R; Schröder M; Stärke C; Urbach D; Nebelung W
    Arthroscopy; 2001 May; 17(5):439-44. PubMed ID: 11337709
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cyclic displacement after meniscal root repair fixation: a human biomechanical evaluation.
    LaPrade RF; LaPrade CM; Ellman MB; Turnbull TL; Cerminara AJ; Wijdicks CA
    Am J Sports Med; 2015 Apr; 43(4):892-8. PubMed ID: 25556220
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair.
    Camarda L; Pitarresi G; Lauria M; Fazzari F; D'Arienzo M
    Arch Orthop Trauma Surg; 2017 Sep; 137(9):1301-1306. PubMed ID: 28674738
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical performance of a collagen meniscus implant with regard to suture material and irrigation fluid.
    Gwinner C; von Roth P; Schmidt S; Ode JE; Wulsten D; Hoburg A
    Knee; 2017 Aug; 24(4):726-732. PubMed ID: 28455166
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The role of suture cutout in the failure of meniscal root repair during the early post-operative period: a biomechanical study.
    Perez-Blanca A; Prado Nóvoa M; Lombardo Torre M; Espejo-Reina A; Ezquerro Juanco F; Espejo-Baena A
    Int Orthop; 2018 Apr; 42(4):811-818. PubMed ID: 29396804
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.