BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

260 related articles for article (PubMed ID: 23091049)

  • 1. Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee.
    Theuns DA; Elvan A; de Voogt W; de Cock CC; van Erven L; Meine M
    Circ Arrhythm Electrophysiol; 2012 Dec; 5(6):1059-63. PubMed ID: 23091049
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors.
    Kodoth VN; Hodkinson EC; Noad RL; Ashfield KP; Cromie NA; McEneaney DJ; Wilson CM; Roberts MJ
    Pacing Clin Electrophysiol; 2012 Dec; 35(12):1498-504. PubMed ID: 23035735
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Canadian experience with Durata and Riata ST Optim defibrillator leads: a report from the Canadian Heart Rhythm Society Device Committee.
    Bennett MT; Ha AC; Exner DV; Tung SK; Parkash R; Connors S; Coutu B; Crystal E; Champagne J; Philippon F; Yee R; Stephenson EA; Nery PB; Essebag V; Sanatani S; Redfearn D; Krahn AD; Healey JS
    Heart Rhythm; 2013 Oct; 10(10):1478-81. PubMed ID: 23973950
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High prevalence of insulation failure with externalized cables in St. Jude Medical Riata family ICD leads: fluoroscopic grading scale and correlation to extracted leads.
    Parvathaneni SV; Ellis CR; Rottman JN
    Heart Rhythm; 2012 Aug; 9(8):1218-24. PubMed ID: 22449742
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors' externalization in Riata leads.
    Kubala M; Traullé S; Leborgne L; Hermida JS
    Europace; 2013 Aug; 15(8):1198-204. PubMed ID: 23388185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prospective nationwide fluoroscopic and electrical longitudinal follow-up of recalled Riata defibrillator leads in Denmark.
    Larsen JM; Nielsen JC; Johansen JB; Haarbo J; Petersen HH; Thøgersen AM; Hjortshøj SP
    Heart Rhythm; 2014 Dec; 11(12):2141-7. PubMed ID: 25008285
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Conductor externalization of the Riata internal cardioverter defibrillator lead: tip of the iceberg? Report of three cases and review of literature.
    Dorman HG; van Opstal JM; Stevenhagen J; Scholten MF
    Europace; 2012 Aug; 14(8):1161-4. PubMed ID: 22431444
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Longitudinal follow-up of externalized Riata leads.
    Liu J; Qin D; Rattan R; Bazaz R; Adelstein E; Jain S; Saba S
    Am J Cardiol; 2013 Nov; 112(10):1616-8. PubMed ID: 24012025
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect.
    Hauser RG; McGriff D; Retel LK
    Heart Rhythm; 2012 May; 9(5):742-9. PubMed ID: 22209723
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads.
    Schmutz M; Delacrétaz E; Schwick N; Roten L; Fuhrer J; Boesch C; Tanner H
    Int J Cardiol; 2013 Jul; 167(1):254-7. PubMed ID: 22236515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluoroscopic investigation of Riata® transvenous defibrillator leads.
    Singh G; Lahiri MK; Khan A; Fang KD; Schuger CD
    Cardiol J; 2015; 22(1):57-67. PubMed ID: 24846515
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nationwide Longitudinal Follow-Up of Riata Leads Under Advisory at 3 Annual Screenings: Report From the Netherlands Heart Rhythm Association Device Advisory Committee.
    Theuns DAMJ; van Erven L; Kimman GP; de Cock CC; Elvan A; Alings MA; van Opstal J; Meine M
    JACC Clin Electrophysiol; 2017 Aug; 3(8):887-893. PubMed ID: 29759787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical and electrical dysfunction of Riata implantable cardioverter-defibrillator leads.
    Demirel F; Adiyaman A; Delnoy PP; Smit JJ; Ramdat Misier AR; Elvan A
    Europace; 2014 Dec; 16(12):1787-94. PubMed ID: 24843049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family.
    Liu J; Rattan R; Adelstein E; Barrington W; Bazaz R; Brode S; Jain S; Mendenhall GS; Nemec J; Razak E; Shalaby A; Schwartzman D; Voigt A; Wang NC; Saba S
    Circ Arrhythm Electrophysiol; 2012 Aug; 5(4):809-14. PubMed ID: 22787015
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prevalence of externalized conductors in Riata and Riata ST silicone leads: results from the prospective, multicenter Riata Lead Evaluation Study.
    Hayes D; Freedman R; Curtis AB; Niebauer M; Neal Kay G; Dinerman J; Beau S
    Heart Rhythm; 2013 Dec; 10(12):1778-82. PubMed ID: 23994078
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lead thrombi associated with externalized cables on Riata ICD leads: a case series.
    Goyal SK; Ellis CR; Rottman JN; Whalen SP
    J Cardiovasc Electrophysiol; 2013 Sep; 24(9):1047-50. PubMed ID: 23577693
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Update on small-diameter implantable cardioverter-defibrillator leads performance.
    van Rees JB; van Welsenes GH; Borleffs CJ; Thijssen J; van der Velde ET; van der Wall EE; van Erven L; Schalij MJ
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):652-8. PubMed ID: 22352338
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multicenter experience with extraction of the Riata/Riata ST ICD lead.
    Maytin M; Wilkoff BL; Brunner M; Cronin E; Love CJ; Grazia Bongiorni M; Segreti L; Carrillo RG; Garisto JD; Kutalek S; Subzposh F; Fischer A; Coffey JO; Gangireddy SR; Saba S; Mittal S; Arshad A; O'Keefe RM; Henrikson CA; Belott P; John RM; Epstein LM
    Heart Rhythm; 2014 Sep; 11(9):1613-8. PubMed ID: 24854215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Externalized conductors and electrical dysfunction in transvenous ventricular leads: Results of the Cardiac Lead Assessment Study.
    Freedman RA; Curtis AB; Delgado SM; Lee LY
    Heart Rhythm O2; 2022 Apr; 3(2):160-168. PubMed ID: 35496462
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prospective long-term evaluation of Optim-insulated (Riata ST Optim and Durata) implantable cardioverter-defibrillator leads.
    Cairns JA; Epstein AE; Rickard J; Connolly SJ; Buller C; Wilkoff BL; Pogue J; Themeles E; Healey JS
    Heart Rhythm; 2014 Dec; 11(12):2156-62. PubMed ID: 25131665
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.