  • 41. Applying usability heuristics to radiotherapy systems.
    Chan AJ; Islam MK; Rosewall T; Jaffray DA; Easty AC; Cafazzo JA
    Radiother Oncol; 2012 Jan; 102(1):142-7. PubMed ID: 21733590
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Reducing medication errors and increasing patient safety: case studies in clinical pharmacology.
    Benjamin DM
    J Clin Pharmacol; 2003 Jul; 43(7):768-83. PubMed ID: 12856392
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Preventing blood transfusion failures: FMEA, an effective assessment method.
    Najafpour Z; Hasoumi M; Behzadi F; Mohamadi E; Jafary M; Saeedi M
    BMC Health Serv Res; 2017 Jun; 17(1):453. PubMed ID: 28666439
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A method for evaluating quality assurance needs in radiation therapy.
    Huq MS; Fraass BA; Dunscombe PB; Gibbons JP; Ibbott GS; Medin PM; Mundt A; Mutic S; Palta JR; Thomadsen BR; Williamson JF; Yorke ED
    Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S170-3. PubMed ID: 18406920
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Introducing a change in hospital policy using FMEA methodology as a tool to reduce patient hazards.
    Ofek F; Magnezi R; Kurzweil Y; Gazit I; Berkovitch S; Tal O
    Isr J Health Policy Res; 2016; 5():30. PubMed ID: 27822358
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Avoiding and identifying errors in health technology assessment models: qualitative study and methodological review.
    Chilcott J; Tappenden P; Rawdin A; Johnson M; Kaltenthaler E; Paisley S; Papaioannou D; Shippam A
    Health Technol Assess; 2010 May; 14(25):iii-iv, ix-xii, 1-107. PubMed ID: 20501062
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Safety and feasibility of STAT RAD: Improvement of a novel rapid tomotherapy-based radiation therapy workflow by failure mode and effects analysis.
    Jones RT; Handsfield L; Read PW; Wilson DD; Van Ausdal R; Schlesinger DJ; Siebers JV; Chen Q
    Pract Radiat Oncol; 2015; 5(2):106-12. PubMed ID: 25413416
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A novel approach to infectious disease control and radiotherapy risk management.
    Islam NM; Wadi-Ramahi SJ; Lalonde R; Baig T; diMayorca M; Clump DA; Huq MS
    Med Phys; 2023 May; 50(5):2683-2694. PubMed ID: 36841994
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Risk analysis of analytical validations by probabilistic modification of FMEA.
    Barends DM; Oldenhof MT; Vredenbregt MJ; Nauta MJ
    J Pharm Biomed Anal; 2012 May; 64-65():82-6. PubMed ID: 22410502
    [TBL] [Abstract][Full Text] [Related]  

  • 50. To err is human: improving patient safety through failure mode and effect analysis.
    Woodhouse S; Burney B; Coste K
    Clin Leadersh Manag Rev; 2004; 18(1):32-6. PubMed ID: 14968751
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Anticipating risk for human subjects participating in clinical research: application of Failure Mode and Effects Analysis.
    Cody RJ
    Cancer Invest; 2006 Mar; 24(2):209-14. PubMed ID: 16537191
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Six Sigma: not for the faint of heart.
    Benedetto AR
    Radiol Manage; 2003; 25(2):40-53. PubMed ID: 12800564
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A FMEA clinical laboratory case study: how to make problems and improvements measurable.
    Capunzo M; Cavallo P; Boccia G; Brunetti L; Pizzuti S
    Clin Leadersh Manag Rev; 2004; 18(1):37-41. PubMed ID: 14968752
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The use of categorized time-trend reporting of radiation oncology incidents: a proactive analytical approach to improving quality and safety over time.
    Arnold A; Delaney GP; Cassapi L; Barton M
    Int J Radiat Oncol Biol Phys; 2010 Dec; 78(5):1548-54. PubMed ID: 20598456
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Implementation of the global risk analysis in pulsed-dose rate brachytherapy: methods and results.
    Mazeron R; Aguini N; Rivin Del Campo E; Dumas I; Gensse MC; Brusadin G; Lefkopoulos D; Deutsch E; Haie-Meder C
    Cancer Radiother; 2015 Apr; 19(2):89-97. PubMed ID: 25600666
    [TBL] [Abstract][Full Text] [Related]  

  • 56. FMEA team performance in health care: A qualitative analysis of team member perceptions.
    Wetterneck TB; Hundt AS; Carayon P
    J Patient Saf; 2009 Jun; 5(2):102-8. PubMed ID: 19920449
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A comparison of two prospective risk analysis methods: Traditional FMEA and a modified healthcare FMEA.
    Rah JE; Manger RP; Yock AD; Kim GY
    Med Phys; 2016 Dec; 43(12):6347. PubMed ID: 27908165
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [The management of the risk due to the manual lifting of patients in a hospital risk-management program].
    Margonari M; Nava C; Basilico S; Petri A
    Med Lav; 1999; 90(2):351-61. PubMed ID: 10371825
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Collection and evaluation of incidents in a radiotherapy department : a reactive risk analysis.
    Portaluri M; Fucilli FI; Gianicolo EA; Tramacere F; Francavilla MC; De Tommaso C; Castagna R; Pili G
    Strahlenther Onkol; 2010 Dec; 186(12):693-9. PubMed ID: 21140128
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Cause-and-effect analysis of risk management files to assess patient care in the emergency department.
    White AA; Wright SW; Blanco R; Lemonds B; Sisco J; Bledsoe S; Irwin C; Isenhour J; Pichert JW
    Acad Emerg Med; 2004 Oct; 11(10):1035-41. PubMed ID: 15466145
    [TBL] [Abstract][Full Text] [Related]  