These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Preliminary observations using optical coherence tomography to assess neointimal coverage of a metal stent in a porcine model. Mills JS; N'diaye CS; Yow E; Urtz M; Povsic TJ; Greenfield JC; Phillips HR Cardiovasc Revasc Med; 2009; 10(4):229-35. PubMed ID: 19815170 [TBL] [Abstract][Full Text] [Related]
4. [Visualization of intimal proliferation of drug-eluting stent and bare mental stent by use of optical coherence tomography]. Chen BX; Ma FY; Luo W; Xie WL; Sun SH; Guo XM; Wang F; Zhao XZ; Chu XW Zhonghua Yi Xue Za Zhi; 2006 Apr; 86(16):1102-6. PubMed ID: 16796834 [TBL] [Abstract][Full Text] [Related]
5. Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: evaluation by optical coherence tomography. Yao ZH; Matsubara T; Inada T; Suzuki Y; Suzuki T Chin Med J (Engl); 2008 Mar; 121(6):503-7. PubMed ID: 18364133 [TBL] [Abstract][Full Text] [Related]
6. Impact of frequency-domain optical coherence tomography guidance for optimal coronary stent implantation in comparison with intravascular ultrasound guidance. Habara M; Nasu K; Terashima M; Kaneda H; Yokota D; Ko E; Ito T; Kurita T; Tanaka N; Kimura M; Ito T; Kinoshita Y; Tsuchikane E; Asakura K; Asakura Y; Katoh O; Suzuki T Circ Cardiovasc Interv; 2012 Apr; 5(2):193-201. PubMed ID: 22456026 [TBL] [Abstract][Full Text] [Related]
7. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods. Poerner TC; Otto S; Gassdorf J; Janiak F; Danzer C; Ferrari M; Figulla HR EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737 [TBL] [Abstract][Full Text] [Related]
8. Neointimal patterns obtained by optical coherence tomography correlate with specific histological components and neointimal proliferation in a swine model of restenosis. Kim JS; Afari ME; Ha J; Tellez A; Milewski K; Conditt G; Cheng Y; Hua Yi G; Kaluza GL; Granada JF Eur Heart J Cardiovasc Imaging; 2014 Mar; 15(3):292-8. PubMed ID: 24022066 [TBL] [Abstract][Full Text] [Related]
10. In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: a comparison with intravascular ultrasound. Kawase Y; Hoshino K; Yoneyama R; McGregor J; Hajjar RJ; Jang IK; Hayase M Ultrasound Med Biol; 2005 Oct; 31(10):1343-9. PubMed ID: 16223637 [TBL] [Abstract][Full Text] [Related]
11. Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, in a rabbit carotid model. Prati F; Zimarino M; Stabile E; Pizzicannella G; Fouad T; Rabozzi R; Filippini A; Pizzicannella J; Cera M; De Caterina R Heart; 2008 Feb; 94(2):217-21. PubMed ID: 17639100 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of neointimal coverage of overlapping sirolimus-eluting stents by optical coherence tomography. Tian F; Chen YD; Sun ZJ; Chen L; Yuan F; Song XT; Lü SZ Chin Med J (Engl); 2009 Mar; 122(6):670-4. PubMed ID: 19323932 [TBL] [Abstract][Full Text] [Related]
13. Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Guagliumi G; Sirbu V Catheter Cardiovasc Interv; 2008 Aug; 72(2):237-47. PubMed ID: 18655155 [TBL] [Abstract][Full Text] [Related]
14. Optical coherence tomography versus intravascular ultrasound in the evaluation of observer variability and reliability in the assessment of stent deployment: the OCTIVUS study. Magnus PC; Jayne JE; Garcia-Garcia HM; Swart M; van Es GA; Tijssen J; Kaplan AV Catheter Cardiovasc Interv; 2015 Aug; 86(2):229-35. PubMed ID: 25620044 [TBL] [Abstract][Full Text] [Related]
15. Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: an optical coherence tomography study. Davlouros PA; Nikokiris G; Karantalis V; Mavronasiou E; Xanthopoulou I; Damelou A; Tsigkas G; Alexopoulos D Int J Cardiol; 2011 Sep; 151(2):155-9. PubMed ID: 20605242 [TBL] [Abstract][Full Text] [Related]
16. In vivo characterisation of bioresorbable vascular scaffold strut interfaces using optical coherence tomography with Gaussian line spread function analysis. Sheehy A; Gutiérrez-Chico JL; Diletti R; Oberhauser JP; Glauser T; Harrington J; Kossuth MB; Rapoza RJ; Onuma Y; Serruys PW EuroIntervention; 2012 Feb; 7(10):1227-35. PubMed ID: 22222916 [TBL] [Abstract][Full Text] [Related]
17. Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy. Templin C; Meyer M; Müller MF; Djonov V; Hlushchuk R; Dimova I; Flueckiger S; Kronen P; Sidler M; Klein K; Nicholls F; Ghadri JR; Weber K; Paunovic D; Corti R; Hoerstrup SP; Lüscher TF; Landmesser U Eur Heart J; 2010 Jul; 31(14):1792-801. PubMed ID: 20525979 [TBL] [Abstract][Full Text] [Related]