These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 2310270)

  • 1. Hypoxemia after intraluminal oxygen line obstruction during cardiopulmonary bypass.
    Dickinson TA
    Ann Thorac Surg; 1990 Mar; 49(3):512. PubMed ID: 2310270
    [No Abstract]   [Full Text] [Related]  

  • 2. Hypoxemia after intraluminal oxygen line obstruction during cardiopulmonary bypass.
    Robblee JA; Crosby E; Keon WJ
    Ann Thorac Surg; 1989 Oct; 48(4):575-6. PubMed ID: 2508584
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hypoxemia during cardiopulmonary bypass.
    Belcher P; Jones R
    Ann Thorac Surg; 1990 Aug; 50(2):336. PubMed ID: 2383134
    [No Abstract]   [Full Text] [Related]  

  • 4. Detection of oxygen delivery failure during cardiopulmonary bypass: an even earlier warning technique.
    Caruso LJ; Gravenstein N; Janelle GM; Gabrielli A
    J Cardiothorac Vasc Anesth; 2002 Dec; 16(6):789. PubMed ID: 12486667
    [No Abstract]   [Full Text] [Related]  

  • 5. Oxygenator failure.
    Kurusz M; Conti VR; Arens JF
    Ann Thorac Surg; 1990 Mar; 49(3):511-2. PubMed ID: 2310269
    [No Abstract]   [Full Text] [Related]  

  • 6. A problem with a Sechrist air/oxygen blender device.
    Wajon P; Walsh R; Symons N
    Anaesth Intensive Care; 1995 Aug; 23(4):518-9. PubMed ID: 7485958
    [No Abstract]   [Full Text] [Related]  

  • 7. Hypothermic Cardiopulmonary Bypass Weaning and Prolonged Postoperative Rewarming in a Patient With Intraoperative Oxygenator Thrombosis.
    Grant I; Breidenstein M; Parsee A; Krumholz C; Martin J
    J Cardiothorac Vasc Anesth; 2018 Aug; 32(4):1851-1854. PubMed ID: 29221982
    [No Abstract]   [Full Text] [Related]  

  • 8. Catastrophic cardiopulmonary bypass accident.
    Roth JV; Fried DW
    J Cardiothorac Vasc Anesth; 1993 Apr; 7(2):253-4. PubMed ID: 8477039
    [No Abstract]   [Full Text] [Related]  

  • 9. Hypoxemia during cardiopulmonary bypass from leaks in the gas supply system.
    Gravlee GP; Wong AB; Charles DJ
    Anesth Analg; 1985 Jun; 64(6):649-50. PubMed ID: 4003785
    [No Abstract]   [Full Text] [Related]  

  • 10. Hypoxemia on Cardiopulmonary Bypass Caused by a Patient's Oxygen Consumption Exceeding the Capacity of a Membrane Oxygenator.
    Majewski MB; Lee R; Chabot D; McGee E; LeVan P
    J Cardiothorac Vasc Anesth; 2019 Sep; 33(9):2521-2524. PubMed ID: 30940495
    [No Abstract]   [Full Text] [Related]  

  • 11. Respiratory dysfunction and white cell activation following cardiopulmonary bypass: comparison of membrane and bubble oxygenators.
    Martin W; Carter R; Tweddel A; Belch J; el-Fiky M; McQuiston AM; McLaren M; Wheatley DJ
    Eur J Cardiothorac Surg; 1996; 10(9):774-83. PubMed ID: 8905281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure.
    Groom RC; Forest RJ; Cormack JE; Niimi KS; Morton J
    Perfusion; 2002 Nov; 17(6):447-50. PubMed ID: 12470036
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gaseous microemboli production of bubble and membrane oxygenators.
    Pearson DT; Holden MP; Poslad SJ
    Life Support Syst; 1986; 4 Suppl 1():198-208. PubMed ID: 3747601
    [No Abstract]   [Full Text] [Related]  

  • 14. Use of Volatile Anesthetic Agent in Extracorporeal Circuit as a Cause of Break in Polycarbonate Connector-Lessons Learnt.
    Gowda D; Rashmi K; Pandarinathan N; Desai N
    J Extra Corpor Technol; 2017 Sep; 49(3):198-200. PubMed ID: 28979044
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of microbubbles released by oxygenators during cardiopulmonary bypass by intraoperative transesophageal echocardiography.
    Meloni L; Abbruzzese PA; Cardu G; Aru GM; Loriga P; Ricchi A; Martelli V; Cherchi A
    Am J Cardiol; 1990 Aug; 66(4):511-4. PubMed ID: 2386124
    [No Abstract]   [Full Text] [Related]  

  • 16. Oxygenation failure during cardiopulmonary bypass prompts new safety algorithm and training initiative.
    Webb DP; Deegan RJ; Greelish JP; Byrne JG
    J Extra Corpor Technol; 2007 Sep; 39(3):188-91. PubMed ID: 17972454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical comparison between membrane and bubble oxygenators in cardiopulmonary bypass.
    Fenchel G; Seybold-Epting W; Schmidt K; Stunkat R; Hoffmeister HE
    J Cardiovasc Surg (Torino); 1979; 20(4):419-22. PubMed ID: 479280
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Complement activation caused by different oxygenators.
    Volanakis JE
    J Thorac Cardiovasc Surg; 1989 Aug; 98(2):292-5. PubMed ID: 2755160
    [No Abstract]   [Full Text] [Related]  

  • 19. Gaseous microemboli: sources, causes, and clinical considerations.
    Kurusz M
    Med Instrum; 1985; 19(2):73-6. PubMed ID: 4000011
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Epoprostenol for the treatment of increasing oxygenator pressure drop during cardiopulmonary bypass. A case report.
    Hjärpe AK; Reinsfelt B
    Perfusion; 2018 Apr; 33(3):228-231. PubMed ID: 28872410
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.