These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
245 related articles for article (PubMed ID: 2310643)
1. Doppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position. Pye M; Weerasana N; Bain WH; Hutton I; Cobbe SM Br Heart J; 1990 Jan; 63(1):41-4. PubMed ID: 2310643 [TBL] [Abstract][Full Text] [Related]
2. Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography. Panidis IP; Ross J; Mintz GS J Am Coll Cardiol; 1986 Aug; 8(2):317-26. PubMed ID: 2942593 [TBL] [Abstract][Full Text] [Related]
3. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses]. Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201 [TBL] [Abstract][Full Text] [Related]
4. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. Williams GA; Labovitz AJ Am J Cardiol; 1985 Aug; 56(4):325-32. PubMed ID: 4025173 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping. Dittrich H; Nicod P; Hoit B; Dalton N; Sahn D Am Heart J; 1988 Jan; 115(1 Pt 1):133-8. PubMed ID: 3336968 [TBL] [Abstract][Full Text] [Related]
6. Analysis of Doppler-obtained velocity curves in functional evaluation of mechanical prosthetic valves in the mitral and aortic positions. Goldrath N; Zimes R; Vered Z J Am Soc Echocardiogr; 1988; 1(3):211-25. PubMed ID: 3272769 [TBL] [Abstract][Full Text] [Related]
7. Doppler echocardiographic characteristics of the Carpentier-Edwards xenograft. Gibbs JL; Wharton GA; Williams GJ Eur Heart J; 1986 Apr; 7(4):353-6. PubMed ID: 3720762 [TBL] [Abstract][Full Text] [Related]
8. Doppler echocardiographic evaluation of normal and thrombosed Björk-Shiley mitral prosthetic valves. Radhakrishnan S; Behl VK; Bajaj R; Bhatia ML; Shrivastava S Int J Cardiol; 1988 Sep; 20(3):387-93. PubMed ID: 3170040 [TBL] [Abstract][Full Text] [Related]
9. Doppler haemodynamic profiles of clinically and echocardiographically normal mitral and aortic valve prostheses. Nihoyannopoulos P; Kambouroglou D; Athanassopoulos G; Nadazdin A; Smith P; Oakley CM Eur Heart J; 1992 Mar; 13(3):348-55. PubMed ID: 1597221 [TBL] [Abstract][Full Text] [Related]
10. [A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses]. Bonaduce D; Breglio R; Conforti G; Montemurro MV; Petretta M; Covino E; Morgano G; Bianchi V G Ital Cardiol; 1990 Jan; 20(1):50-7. PubMed ID: 2328859 [TBL] [Abstract][Full Text] [Related]
11. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study. Lindower PD; Dellsperger KC; Johnson B; Chandran KB; Vandenberg BF J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518 [TBL] [Abstract][Full Text] [Related]
12. [Intracardiac flow dynamic alterations with a prosthetic mitral valve studied by pulsed Doppler technique]. Kitabatake A; Tanouchi J; Asao M; Mishima M; Ishihara K; Masuyama T; Inoue M; Abe H; Matsuo H; Morita H J Cardiogr; 1985 Jun; 15(2):469-82. PubMed ID: 4093627 [TBL] [Abstract][Full Text] [Related]
13. Comparative phonocardiographic, echocardiographic and Doppler echocardiographic evaluation of normally functioning Medtronic Hall and Björk-Shiley mitral prosthetic valves. Fukuda N; Oki T; Tabata T; Hosoi K; Iuchi A; Manabe K; Kageji Y; Sasaki M; Hama M; Ito S J Heart Valve Dis; 1994 May; 3(3):275-82. PubMed ID: 8087264 [TBL] [Abstract][Full Text] [Related]
14. Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic values. Sagar KB; Wann LS; Paulsen WH; Romhilt DW J Am Coll Cardiol; 1986 Mar; 7(3):681-7. PubMed ID: 3950245 [TBL] [Abstract][Full Text] [Related]
15. Doppler echocardiographic evaluation of St. Jude Medical valves in the tricuspid position: criteria for normal and abnormal valve function. Sezai A; Shiono M; Akiyama K; Orime Y; Hata H; Yagi S; Tsukamoto S; Nakata K; Hata M; Negishi N; Sezai Y J Cardiovasc Surg (Torino); 2001 Jun; 42(3):303-9. PubMed ID: 11398024 [TBL] [Abstract][Full Text] [Related]