These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 23106914)

  • 1. Bench-to-bedside review: An approach to hemodynamic monitoring--Guyton at the bedside.
    Magder S
    Crit Care; 2012 Oct; 16(5):236. PubMed ID: 23106914
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Understanding Guyton's venous return curves.
    Beard DA; Feigl EO
    Am J Physiol Heart Circ Physiol; 2011 Sep; 301(3):H629-33. PubMed ID: 21666119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical review: Guyton--the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output.
    Henderson WR; Griesdale DE; Walley KR; Sheel AW
    Crit Care; 2010; 14(6):243. PubMed ID: 21144008
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A computational model-based validation of Guyton's analysis of cardiac output and venous return curves.
    Mukkamala R; Cohen RJ; Mark RG
    Comput Cardiol; 2002; 29():561-4. PubMed ID: 14686453
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Venous return and mean systemic filling pressure: physiology and clinical applications.
    Persichini R; Lai C; Teboul JL; Adda I; Guérin L; Monnet X
    Crit Care; 2022 May; 26(1):150. PubMed ID: 35610620
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Mitzner W
    J Appl Physiol (1985); 2006 Nov; 101(5):1529-30. PubMed ID: 17094188
    [No Abstract]   [Full Text] [Related]  

  • 7. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Rothe C
    J Appl Physiol (1985); 2006 Nov; 101(5):1529. PubMed ID: 17094185
    [No Abstract]   [Full Text] [Related]  

  • 8. Testing Computer Models Predicting Human Responses to a High-Salt Diet.
    Kurtz TW; DiCarlo SE; Pravenec M; Ježek F; Šilar J; Kofránek J; Morris RC
    Hypertension; 2018 Dec; 72(6):1407-1416. PubMed ID: 30571226
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Counterpoint: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is not correct.
    Brengelmann GL
    J Appl Physiol (1985); 2006 Nov; 101(5):1525-6; discussion 1526-7. PubMed ID: 17043330
    [No Abstract]   [Full Text] [Related]  

  • 10. Point: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Magder S
    J Appl Physiol (1985); 2006 Nov; 101(5):1523-5. PubMed ID: 16825521
    [No Abstract]   [Full Text] [Related]  

  • 11. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Permutt S
    J Appl Physiol (1985); 2006 Nov; 101(5):1528. PubMed ID: 17094182
    [No Abstract]   [Full Text] [Related]  

  • 12. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Pinsky MR
    J Appl Physiol (1985); 2006 Nov; 101(5):1528. PubMed ID: 16931559
    [No Abstract]   [Full Text] [Related]  

  • 13. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Baker RD
    J Appl Physiol (1985); 2006 Nov; 101(5):1529. PubMed ID: 17094184
    [No Abstract]   [Full Text] [Related]  

  • 14. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Wang LY; Wang WK
    J Appl Physiol (1985); 2006 Nov; 101(5):1528-9. PubMed ID: 17094183
    [No Abstract]   [Full Text] [Related]  

  • 15. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Brengelmann GL
    J Appl Physiol (1985); 2006 Nov; 101(5):1532. PubMed ID: 17043333
    [No Abstract]   [Full Text] [Related]  

  • 16. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Magder S
    J Appl Physiol (1985); 2006 Nov; 101(5):1533. PubMed ID: 16931558
    [No Abstract]   [Full Text] [Related]  

  • 17. Estimated venous return surface and cardiac output curve precisely predicts new hemodynamics after volume change.
    Sugimachi M; Sunagawa K; Uemura K; Kamiya A; Shimizu S; Inagaki M; Shishido T
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():5205-8. PubMed ID: 21096038
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of Guyton's approach to the control of cardiac output for clinical fluid management.
    Magder S
    Ann Intensive Care; 2024 Jul; 14(1):105. PubMed ID: 38963533
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pressure Waveform Analysis.
    Jozwiak M; Monnet X; Teboul JL
    Anesth Analg; 2018 Jun; 126(6):1930-1933. PubMed ID: 29077613
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimally invasive monitoring.
    Monnet X; Teboul JL
    Crit Care Clin; 2015 Jan; 31(1):25-42. PubMed ID: 25435477
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.