BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 23109392)

  • 1. Rapid spectrophotometric technique for quantifying iron in cells labeled with superparamagnetic iron oxide nanoparticles: potential translation to the clinic.
    Dadashzadeh ER; Hobson M; Henry Bryant L; Dean DD; Frank JA
    Contrast Media Mol Imaging; 2013; 8(1):50-6. PubMed ID: 23109392
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro labeling of endothelial progenitor cells isolated from peripheral blood with superparamagnetic iron oxide nanoparticles.
    Sun JH; Zhang YL; Nie CH; Qian SP; Yu XB; Xie HY; Zhou L; Zheng SS
    Mol Med Rep; 2012 Aug; 6(2):282-6. PubMed ID: 22580964
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of viability of transplanted beta cells labeled with a novel contrast agent - polyvinylpyrrolidone-coated superparamagnetic iron oxide nanoparticles by magnetic resonance imaging.
    Zhang B; Jiang B; Chen Y; Huang H; Xie Q; Kang M; Zhang H; Zhai C; Wu Y
    Contrast Media Mol Imaging; 2012; 7(1):35-44. PubMed ID: 22344878
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetic resonance cell-tracking studies: spectrophotometry-based method for the quantification of cellular iron content after loading with superparamagnetic iron oxide nanoparticles.
    Böhm I
    Mol Imaging; 2011 Aug; 10(4):270-7. PubMed ID: 21501568
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of synthetic superparamagnetic iron oxide on dendritic cells.
    Mou Y; Chen B; Zhang Y; Hou Y; Xie H; Xia G; Tang M; Huang X; Ni Y; Hu Q
    Int J Nanomedicine; 2011; 6():1779-86. PubMed ID: 21980240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhanced cellular uptake of aminosilane-coated superparamagnetic iron oxide nanoparticles in mammalian cell lines.
    Zhu XM; Wang YX; Leung KC; Lee SF; Zhao F; Wang DW; Lai JM; Wan C; Cheng CH; Ahuja AT
    Int J Nanomedicine; 2012; 7():953-64. PubMed ID: 22393292
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo migration of dendritic cells labeled with synthetic superparamagnetic iron oxide.
    Mou Y; Hou Y; Chen B; Hua Z; Zhang Y; Xie H; Xia G; Wang Z; Huang X; Han W; Ni Y; Hu Q
    Int J Nanomedicine; 2011; 6():2633-40. PubMed ID: 22114494
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intracellular SPIO labeling of microglia: high field considerations and limitations for MR microscopy.
    Rosenberg JT; Sachi-Kocher A; Davidson MW; Grant SC
    Contrast Media Mol Imaging; 2012; 7(2):121-9. PubMed ID: 22434624
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physical and biological characterization of superparamagnetic iron oxide- and ultrasmall superparamagnetic iron oxide-labeled cells: a comparison.
    Sun R; Dittrich J; Le-Huu M; Mueller MM; Bedke J; Kartenbeck J; Lehmann WD; Krueger R; Bock M; Huss R; Seliger C; Gröne HJ; Misselwitz B; Semmler W; Kiessling F
    Invest Radiol; 2005 Aug; 40(8):504-13. PubMed ID: 16024988
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [MR imaging of polyethylenimine-superparamagnetic iron oxide nanoparticle labeled bone marrow mesenchymal stem cells in vitro].
    Chen HZ; Guo YK; Li ZL; Xia R; Zhang LZ; Hou JL; Gao FB; Ai H; Ning G
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2012 Jul; 43(4):578-83. PubMed ID: 22997900
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of superparamagnetic iron oxide (SPIO)-labeled cells using MRI.
    Rad AM; Arbab AS; Iskander AS; Jiang Q; Soltanian-Zadeh H
    J Magn Reson Imaging; 2007 Aug; 26(2):366-74. PubMed ID: 17623892
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [MR imaging of embryonic stem cells labeled by superparamagnetic iron oxide].
    Wang B; Jaconi M; Li J; Wang Y; Valle JP
    Zhonghua Yi Xue Za Zhi; 2007 Jun; 87(23):1646-8. PubMed ID: 17803860
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Magnetic resonance imaging of single SPIO labeled mesenchymal stem cells at 3 Tesla].
    Peldschus K; Kaul M; Lange C; Nolte-Ernsting C; Adam G; Ittrich H
    Rofo; 2007 May; 179(5):473-9. PubMed ID: 17436181
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contribution of macrophages in the contrast loss in iron oxide-based MRI cancer cell tracking studies.
    Danhier P; Deumer G; Joudiou N; Bouzin C; Levêque P; Haufroid V; Jordan BF; Feron O; Sonveaux P; Gallez B
    Oncotarget; 2017 Jun; 8(24):38876-38885. PubMed ID: 28467814
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Magnetic resonance signal detection of superparamagnetic iron oxide nanoparticles and its biological effects on endothelial cells].
    Tan YB; Wu XY; Zhang JF; Zhang MM
    Zhejiang Da Xue Xue Bao Yi Xue Ban; 2010 Mar; 39(2):118-24. PubMed ID: 20387237
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Europium doping of superparamagnetic iron oxide nanoparticles enables their detection by fluorescence microscopy and for quantitative analytics.
    Kobayashi Y; Hauptmann R; Kratz H; Ebert M; Wagner S; Taupitz M
    Technol Health Care; 2017; 25(3):457-470. PubMed ID: 27935574
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A reliable protocol for colorimetric determination of iron oxide nanoparticle uptake by cells.
    Deda DK; Cardoso RM; Uchiyama MK; Pavani C; Toma SH; Baptista MS; Araki K
    Anal Bioanal Chem; 2017 Nov; 409(28):6663-6675. PubMed ID: 28918472
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Superparamagnetic iron oxide nanoparticle-labeled cells as an effective vehicle for tracking the GFP gene marker using magnetic resonance imaging.
    Zhang Z; Mascheri N; Dharmakumar R; Fan Z; Paunesku T; Woloschak G; Li D
    Cytotherapy; 2009; 11(1):43-51. PubMed ID: 18956269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo tracking of mesenchymal stem cells labeled with a novel chitosan-coated superparamagnetic iron oxide nanoparticles using 3.0T MRI.
    Reddy AM; Kwak BK; Shim HJ; Ahn C; Lee HS; Suh YJ; Park ES
    J Korean Med Sci; 2010 Feb; 25(2):211-9. PubMed ID: 20119572
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Somatic differentiation and MR imaging of magnetically labeled human embryonic stem cells.
    Nejadnik H; Henning TD; Castaneda RT; Boddington S; Taubert S; Jha P; Tavri S; Golovko D; Ackerman L; Meier R; Daldrup-Link HE
    Cell Transplant; 2012; 21(12):2555-67. PubMed ID: 22862886
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.