91 related articles for article (PubMed ID: 23111523)
1. Validation of the photon dose calculation model in the VARSKIN 4 skin dose computer code.
Sherbini S; Decicco J; Struckmeyer R; Saba M; Bush-Goddard S
Health Phys; 2012 Dec; 103(6):763-9. PubMed ID: 23111523
[TBL] [Abstract][Full Text] [Related]
2. Verification of the VARSKIN beta skin dose calculation computer code.
Sherbini S; DeCicco J; Gray AT; Struckmeyer R
Health Phys; 2008 Jun; 94(6):527-38. PubMed ID: 18469586
[TBL] [Abstract][Full Text] [Related]
3. The new VARSKIN 4 photon skin dosimetry model.
Hamby DM; Lodwick CJ; Palmer TS; Reese SR; Higley KA; Caffrey JA; Sherbini S; Saba M; Bush-Goddard SP
Radiat Prot Dosimetry; 2013; 154(3):356-63. PubMed ID: 23070483
[TBL] [Abstract][Full Text] [Related]
4. A COMPARISON OF BETA SKIN DOSES CALCULATED WITH VARSKIN 5.35.3 AND MCNP5.
Dubeau J; Hakmana Witharana SS; Sun J; Heinmiller BE; Chase WJ
Radiat Prot Dosimetry; 2018 Dec; 182(4):502-507. PubMed ID: 30053277
[TBL] [Abstract][Full Text] [Related]
5. Estimation of the dose to the nursing infant due to direct irradiation from activity present in maternal organs and tissues.
Hunt JG; Nosske D; dos Santos DS
Radiat Prot Dosimetry; 2005; 113(3):290-9. PubMed ID: 15755774
[TBL] [Abstract][Full Text] [Related]
6. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
[TBL] [Abstract][Full Text] [Related]
7. Validation of the Swiss Monte Carlo Plan for a static and dynamic 6 MV photon beam.
Magaddino V; Manser P; Frei D; Volken W; Schmidhalter D; Hirschi L; Fix MK
Z Med Phys; 2011 May; 21(2):124-34. PubMed ID: 21239148
[TBL] [Abstract][Full Text] [Related]
8. Skin dose from radionuclide contamination on clothing.
Taylor DC; Hussein EM; Yuen PS
Health Phys; 1997 Jun; 72(6):835-41. PubMed ID: 9169925
[TBL] [Abstract][Full Text] [Related]
9. Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport.
Jia X; Gu X; Sempau J; Choi D; Majumdar A; Jiang SB
Phys Med Biol; 2010 Jun; 55(11):3077-86. PubMed ID: 20463376
[TBL] [Abstract][Full Text] [Related]
10. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of skin absorbed doses during manipulation of radioactive sources: a comparison between the VARSKIN code and Monte Carlo simulations.
Amato E; Italiano A
J Radiol Prot; 2018 Mar; 38(1):262-272. PubMed ID: 29235449
[TBL] [Abstract][Full Text] [Related]
12. Optimising cylinder model dimensions for VARSKIN to simulate a droplet of radionuclide skin contamination using Geant4 Monte Carlo code.
James G; O'Brien J; Thomson B
Nucl Med Commun; 2023 May; 44(5):366-374. PubMed ID: 36897054
[TBL] [Abstract][Full Text] [Related]
13. Doppler broadening effect on low-energy photon dose calculations using MCNP5 and PENELOPE.
Ye SJ; Ove R; Naqvi SA
Health Phys; 2006 Oct; 91(4):361-6. PubMed ID: 16966879
[TBL] [Abstract][Full Text] [Related]
14. Effects of off-centering on dose uniformity along and around blood vessels undergoing catheter-based intravascular brachytherapy.
Nath R; Yue N
Cardiovasc Radiat Med; 2004; 5(2):88-96. PubMed ID: 15464946
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.
Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P
Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo simulation of small electron fields collimated by the integrated photon MLC.
Mihaljevic J; Soukup M; Dohm O; Alber M
Phys Med Biol; 2011 Feb; 56(3):829-43. PubMed ID: 21242628
[TBL] [Abstract][Full Text] [Related]
17. Monte carlo dose calculations in conventional thorax fields for 60Co photons.
Mesbahi A; Allahverdi M; Gheraati H
Radiat Med; 2005 Aug; 23(5):341-50. PubMed ID: 16342907
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo calculation and silicon detector measurement of the hot particle dose.
Chung MH; Levine SH; Jester WA
Health Phys; 1991 Dec; 61(6):843-8. PubMed ID: 1955329
[TBL] [Abstract][Full Text] [Related]
19. Investigation of voxel warping and energy mapping approaches for fast 4D Monte Carlo dose calculations in deformed geometries using VMC++.
Heath E; Tessier F; Kawrakow I
Phys Med Biol; 2011 Aug; 56(16):5187-202. PubMed ID: 21791733
[TBL] [Abstract][Full Text] [Related]
20. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]