These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 23113976)

  • 1. The measurement of 25-hydroxy vitamin D - an analytical challenge.
    Herrmann M
    Clin Chem Lab Med; 2012 Nov; 50(11):1873-5. PubMed ID: 23113976
    [No Abstract]   [Full Text] [Related]  

  • 2. Measurement of 25-hydroxyvitamin vitamin D by liquid chromatography tandem-mass spectrometry with comparison to automated immunoassays.
    Carrozza C; Persichilli S; Canu G; Gervasoni J; Torti E; Tazza L; Zuppi C
    Clin Chem Lab Med; 2012 Nov; 50(11):2033-5. PubMed ID: 22740579
    [No Abstract]   [Full Text] [Related]  

  • 3. [Vitamin D measurement: pre-analytical and analytical considerations].
    Le Goff C; Souberbielle JC; Delvin E; Cavalier É
    Ann Biol Clin (Paris); 2015; 73(1):79-92. PubMed ID: 25582725
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experience with the first fully automated chemiluminescence immunoassay for the quantification of 1α, 25-dihydroxy-vitamin D.
    van Helden J; Weiskirchen R
    Clin Chem Lab Med; 2015 Apr; 53(5):761-70. PubMed ID: 25274943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [How to measure vitamin D status?].
    Dahl SR; Thorsby PM
    Tidsskr Nor Laegeforen; 2014 Apr; 134(7):729-31. PubMed ID: 24721864
    [No Abstract]   [Full Text] [Related]  

  • 6. Analytical evaluation of a new automated protein binding assay to determine 25-hydroxyvitamin D concentrations.
    Franken WP; Vingerhoed J; Buijs MM
    Clin Chem Lab Med; 2012 Nov; 50(11):2037-9. PubMed ID: 23092798
    [No Abstract]   [Full Text] [Related]  

  • 7. Vitamin D assays: past and present debates, difficulties, and developments.
    Fraser WD; Milan AM
    Calcif Tissue Int; 2013 Feb; 92(2):118-27. PubMed ID: 23314742
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The new Roche Vitamin D Total assay: fit for its purpose?
    Emmen JM; Wielders JP; Boer AK; van den Ouweland JM; Vader HL
    Clin Chem Lab Med; 2012 Nov; 50(11):1969-72. PubMed ID: 23113978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Vitamin D status of county hospital patients assessed by the DiaSorin LIAISON® 25-hydroxyvitamin D assay.
    French D; Gorgi AW; Ihenetu KU; Weeks MA; Lynch KL; Wu AH
    Clin Chim Acta; 2011 Jan; 412(3-4):258-62. PubMed ID: 20965160
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analytical validation of the Roche 25-OH Vitamin D Total assay.
    Knudsen CS; Nexo E; Højskov CS; Heickendorff L
    Clin Chem Lab Med; 2012 Nov; 50(11):1965-8. PubMed ID: 23093282
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Guiding Appropriate Laboratory Test Utilization: 1,25-OH-Vitamin D.
    Wilhelms KW; Sanderson JL; Platteborze PL
    Mil Med; 2016 Jan; 181(1):10-1. PubMed ID: 26741470
    [No Abstract]   [Full Text] [Related]  

  • 12. First 25-hydroxyvitamin D assay for general chemistry analyzers.
    Saida FB; Chen X; Tran K; Dou C; Yuan C
    Expert Rev Mol Diagn; 2015 Mar; 15(3):313-23. PubMed ID: 25434745
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The measurement of vitamin D: analytical aspects.
    Zerwekh JE
    Ann Clin Biochem; 2004 Jul; 41(Pt 4):272-81. PubMed ID: 15298739
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A fast and simple method for simultaneous measurements of 25(OH)D, 24,25(OH)
    Fabregat-Cabello N; Farre-Segura J; Huyghebaert L; Peeters S; Le Goff C; Souberbielle JC; Cavalier É
    Clin Chim Acta; 2017 Oct; 473():116-123. PubMed ID: 28842174
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 25-Hydroxyvitamin D testing: challenging the performance of current automated immunoassays.
    Farrell C; Soldo J; Williams P; Herrmann M
    Clin Chem Lab Med; 2012 Nov; 50(11):1953-63. PubMed ID: 23113977
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis.
    Stöckl D; Sluss PM; Thienpont LM
    Clin Chim Acta; 2009 Oct; 408(1-2):8-13. PubMed ID: 19563791
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry.
    Kocak FE; Ozturk B; Isiklar OO; Genc O; Unlu A; Altuntas I
    Biochem Med (Zagreb); 2015; 25(3):430-8. PubMed ID: 26526462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Elecsys® Vitamin B12 assay is not affected by anti-intrinsic factor antibodies.
    Schilling KA; Wiesgigl M
    Clin Chem Lab Med; 2013 Jun; 51(11):e251-2. PubMed ID: 23813358
    [No Abstract]   [Full Text] [Related]  

  • 19. Quantitative analytical method to evaluate the metabolism of vitamin D.
    Mena-Bravo A; Ferreiro-Vera C; Priego-Capote F; Maestro MA; Mouriño A; Quesada-Gómez JM; Luque de Castro MD
    Clin Chim Acta; 2015 Mar; 442():6-12. PubMed ID: 25575651
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated measurement of 25-OH Vitamin D on the LUMIPULSE
    Parra M; Foj L; Filella X
    Br J Biomed Sci; 2016 Jul; 73(3):104-109. PubMed ID: 27310165
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.