These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
314 related articles for article (PubMed ID: 23114293)
1. Percutaneous core needle biopsy versus open biopsy in diagnostics of bone and soft tissue sarcoma: a retrospective study. Pohlig F; Kirchhoff C; Lenze U; Schauwecker J; Burgkart R; Rechl H; von Eisenhart-Rothe R Eur J Med Res; 2012 Nov; 17(1):29. PubMed ID: 23114293 [TBL] [Abstract][Full Text] [Related]
2. Is Core Needle Biopsy Reliable in Differentiating Between Aggressive Benign and Malignant Radiolucent Bone Tumors? Hegde V; Burke ZDC; Park HY; Zoller SD; Johansen D; Kelley BV; Levine B; Motamedi K; Federman NC; Seeger LL; Nelson SD; Bernthal NM Clin Orthop Relat Res; 2018 Mar; 476(3):568-577. PubMed ID: 29529643 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of core needle biopsy as a substitute to open biopsy in the diagnosis of soft-tissue masses. Ray-Coquard I; Ranchère-Vince D; Thiesse P; Ghesquières H; Biron P; Sunyach MP; Rivoire M; Lancry L; Méeus P; Sebban C; Blay JY Eur J Cancer; 2003 Sep; 39(14):2021-5. PubMed ID: 12957456 [TBL] [Abstract][Full Text] [Related]
4. Diagnostic value and accuracy of imprint cytology evaluation during image-guided core needle biopsies: Review of our experience at a large academic center. Kubik MJ; Bovbel A; Goli H; Saremian J; Siddiqi A; Masood S Diagn Cytopathol; 2015 Oct; 43(10):773-9. PubMed ID: 26119885 [TBL] [Abstract][Full Text] [Related]
5. Comparative cytological and histological assessment of 828 primary soft tissue and bone lesions, and proposal for a system for reporting soft tissue cytopathology. Köster J; Ghanei I; Domanski HA Cytopathology; 2021 Jan; 32(1):7-19. PubMed ID: 32926591 [TBL] [Abstract][Full Text] [Related]
6. Diagnostic yield of percutaneous core needle biopsy in suspected soft tissue lesions of extremities. Qi D; Zhao M; Hu T; Zhang G J Int Med Res; 2019 Jun; 47(6):2598-2606. PubMed ID: 31117871 [TBL] [Abstract][Full Text] [Related]
7. Comparison of the diagnostic performances of core needle biopsy in myxoid versus non-myxoid tumors. Rohela H; Lee C; Yoo HJ; Kim HS; Kim Y; Cho HS; Han I Eur J Surg Oncol; 2019 Jul; 45(7):1293-1298. PubMed ID: 31085026 [TBL] [Abstract][Full Text] [Related]
8. [Diagnostic value of ultrasound-guided core needle biopsy for soft tissue tumors]. Na J; Fang ZW; Zhao AL; Li JY Zhonghua Bing Li Xue Za Zhi; 2013 Mar; 42(3):158-62. PubMed ID: 23769433 [TBL] [Abstract][Full Text] [Related]
9. Diagnostic accuracy of ultrasound-guided core needle biopsy versus incisional biopsy in soft tissue sarcoma: an institutional experience. Cernakova M; Hobusch GM; Amann G; Funovics PT; Windhager R; Panotopoulos J Sci Rep; 2021 Sep; 11(1):17832. PubMed ID: 34497298 [TBL] [Abstract][Full Text] [Related]
10. Diagnostic accuracy and safety of percutaneous core needle biopsy of retroperitoneal tumours. Nardi W; Nicolas N; El Zein S; Tzanis D; Bouhadiba T; Helfre S; Watson S; Brisse HJ; Servois V; Bonvalot S Eur J Surg Oncol; 2024 Jan; 50(1):107298. PubMed ID: 38086314 [TBL] [Abstract][Full Text] [Related]
11. The diagnostic value of needle biopsy for musculoskeletal lesions. Sung KS; Seo SW; Shon MS Int Orthop; 2009 Dec; 33(6):1701-6. PubMed ID: 19655141 [TBL] [Abstract][Full Text] [Related]
12. Core needle biopsy versus incisional biopsy for differentiation of soft-tissue sarcomas: A systematic review and meta-analysis. Birgin E; Yang C; Hetjens S; Reissfelder C; Hohenberger P; Rahbari NN Cancer; 2020 Jan; 126(9):1917-1928. PubMed ID: 32022262 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of core needle biopsy for histologic diagnosis of soft tissue sarcoma. Kiefer J; Mutschler M; Kurz P; Stark GB; Bannasch H; Simunovic F Sci Rep; 2022 Feb; 12(1):1886. PubMed ID: 35115589 [TBL] [Abstract][Full Text] [Related]
14. Computed tomography-guided core needle biopsy versus incisional biopsy in diagnosing musculoskeletal lesions. Kiatisevi P; Thanakit V; Sukunthanak B; Boonthatip M; Bumrungchart S; Witoonchart K J Orthop Surg (Hong Kong); 2013 Aug; 21(2):204-8. PubMed ID: 24014785 [TBL] [Abstract][Full Text] [Related]
15. Core needle biopsy for diagnosis of extremity soft tissue sarcoma. Heslin MJ; Lewis JJ; Woodruff JM; Brennan MF Ann Surg Oncol; 1997; 4(5):425-31. PubMed ID: 9259971 [TBL] [Abstract][Full Text] [Related]
16. The role of core needle biopsy in the diagnosis of suspected soft tissue tumours. Strauss DC; Qureshi YA; Hayes AJ; Thway K; Fisher C; Thomas JM J Surg Oncol; 2010 Oct; 102(5):523-9. PubMed ID: 20872955 [TBL] [Abstract][Full Text] [Related]
17. High diagnostic accuracy of core needle biopsy of soft tissue tumors: An institutional experience. Colletti SM; Tranesh GA; Whetsell CR; Chambers LN; Nassar A Diagn Cytopathol; 2016 Apr; 44(4):291-8. PubMed ID: 26799242 [TBL] [Abstract][Full Text] [Related]
18. Computed tomography-guided core needle biopsy for bone and soft tissue tumors. Issakov J; Flusser G; Kollender Y; Merimsky O; Lifschitz-Mercer B; Meller I Isr Med Assoc J; 2003 Jan; 5(1):28-30. PubMed ID: 12592954 [TBL] [Abstract][Full Text] [Related]
19. Comparative study of diagnostic accuracy between office-based closed needle biopsy and open incisional biopsy in patients with musculoskeletal sarcomas. Srisawat P; Veeraphun P; Punyaratabandhu T; Chareonvareekul S; Songpattanasilpa T; Sritanabutr P; Pipithkul S J Med Assoc Thai; 2014 Feb; 97 Suppl 2():S30-8. PubMed ID: 25518173 [TBL] [Abstract][Full Text] [Related]
20. Musculoskeletal small biopsies from small patients: current status in 2 academic hospitals. Agrawal T; Monaco SE J Am Soc Cytopathol; 2020; 9(5):442-449. PubMed ID: 32654990 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]