These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
261 related articles for article (PubMed ID: 23114412)
21. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Katthagen JC; Schwarze M; Warnhoff M; Voigt C; Hurschler C; Lill H Injury; 2016 Mar; 47(3):617-24. PubMed ID: 26804939 [TBL] [Abstract][Full Text] [Related]
22. Relationship of cortical thickness of the proximal humerus and pullout strength of a locked plate and screw construct. Wallace MJ; Bledsoe G; Moed BR; Israel HA; Kaar SG J Orthop Trauma; 2012 Apr; 26(4):222-5. PubMed ID: 22207205 [TBL] [Abstract][Full Text] [Related]
23. Impact of cement-augmented condylar screws in locking plate osteosynthesis for distal femoral fractures - A biomechanical analysis. Bliemel C; Oberkircher L; Bockmann B; Petzold E; Aigner R; Heyse TJ; Ruchholtz S; Buecking B Injury; 2016 Dec; 47(12):2688-2693. PubMed ID: 27773369 [TBL] [Abstract][Full Text] [Related]
24. Locked vs. unlocked plate osteosynthesis of the proximal humerus - a biomechanical study. Seide K; Triebe J; Faschingbauer M; Schulz AP; Püschel K; Mehrtens G; Jürgens Ch Clin Biomech (Bristol); 2007 Feb; 22(2):176-82. PubMed ID: 17134800 [TBL] [Abstract][Full Text] [Related]
25. The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus. Bae JH; Oh JK; Chon CS; Oh CW; Hwang JH; Yoon YC J Bone Joint Surg Br; 2011 Jul; 93(7):937-41. PubMed ID: 21705567 [TBL] [Abstract][Full Text] [Related]
26. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures. Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H Clin Biomech (Bristol); 2014 Aug; 29(7):735-41. PubMed ID: 24997810 [TBL] [Abstract][Full Text] [Related]
27. Primary stability of cement augmentation in locking plate fixation for proximal humeral fractures: A comparison of absorbable versus non-absorbable cement. Schöbel T; Schleifenbaum S; Nitsch V; Hepp P; Theopold J Clin Biomech (Bristol); 2022 Jan; 91():105516. PubMed ID: 34814041 [TBL] [Abstract][Full Text] [Related]
28. Mechanisms of failure of locked-plate fixation of the proximal humerus: acoustic emissions as a novel assessment modality. Hymes RA; Levine MJ; Schulman JE; Westbrook RD; Li J J Orthop Trauma; 2013 Jul; 27(7):392-8. PubMed ID: 23187155 [TBL] [Abstract][Full Text] [Related]
29. Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement. Stankewich CJ; Swiontkowski MF; Tencer AF; Yetkinler DN; Poser RD J Orthop Res; 1996 Sep; 14(5):786-93. PubMed ID: 8893773 [TBL] [Abstract][Full Text] [Related]
30. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. Siffri PC; Peindl RD; Coley ER; Norton J; Connor PM; Kellam JF J Orthop Trauma; 2006 Sep; 20(8):547-54. PubMed ID: 16990726 [TBL] [Abstract][Full Text] [Related]
31. Comparison of fibula strut and calcium phosphate cement augmentation of the medial buttress in 2-part proximal humerus fractures reconstruction: a biomechanical study. Pokhvashchev D; Knox R; Herring M; Herfat S; Tibrin Marmor M Eur J Orthop Surg Traumatol; 2023 Jan; 33(1):67-72. PubMed ID: 34739600 [TBL] [Abstract][Full Text] [Related]
32. The role of medial comminution and calcar restoration in varus collapse of proximal humeral fractures treated with locking plates. Ponce BA; Thompson KJ; Raghava P; Eberhardt AW; Tate JP; Volgas DA; Stannard JP J Bone Joint Surg Am; 2013 Aug; 95(16):e113(1-7). PubMed ID: 23965707 [TBL] [Abstract][Full Text] [Related]
33. Augmented screws in angular stable plating of the proximal humerus: what to do when revision is needed? Goetzen M; Windolf M; Schmoelz W Clin Biomech (Bristol); 2014 Nov; 29(9):1023-6. PubMed ID: 25270894 [TBL] [Abstract][Full Text] [Related]
34. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations. Estes C; Rhee P; Shrader MW; Csavina K; Jacofsky MC; Jacofsky DJ J Orthop Trauma; 2008; 22(5):312-6. PubMed ID: 18448984 [TBL] [Abstract][Full Text] [Related]
35. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures. Schliemann B; Risse N; Frank A; Müller M; Michel P; Raschke MJ; Katthagen JC Clin Biomech (Bristol); 2019 Mar; 63():21-26. PubMed ID: 30784787 [TBL] [Abstract][Full Text] [Related]
36. The position and number of screws influence screw perforation of the humeral head in modern locking plates: a cadaver study. Erhardt JB; Stoffel K; Kampshoff J; Badur N; Yates P; Kuster MS J Orthop Trauma; 2012 Oct; 26(10):e188-92. PubMed ID: 22357093 [TBL] [Abstract][Full Text] [Related]
37. The effect of in situ augmentation on implant anchorage in proximal humeral head fractures. Unger S; Erhart S; Kralinger F; Blauth M; Schmoelz W Injury; 2012 Oct; 43(10):1759-63. PubMed ID: 22824159 [TBL] [Abstract][Full Text] [Related]
38. Biomechanical comparison of conventional open reduction and internal fixation versus calcium phosphate cement fixation of a central depressed tibial plateau fracture. Yetkinler DN; McClellan RT; Reindel ES; Carter D; Poser RD J Orthop Trauma; 2001; 15(3):197-206. PubMed ID: 11265011 [TBL] [Abstract][Full Text] [Related]
39. Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures. Jabran A; Peach C; Zou Z; Ren L Proc Inst Mech Eng H; 2019 Mar; 233(3):372-382. PubMed ID: 30700217 [TBL] [Abstract][Full Text] [Related]
40. Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures--a biomechanical cadaver study. Fensky F; Nüchtern JV; Kolb JP; Huber S; Rupprecht M; Jauch SY; Sellenschloh K; Püschel K; Morlock MM; Rueger JM; Lehmann W Injury; 2013 Jun; 44(6):802-7. PubMed ID: 23545113 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]