These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Systematic fluoroscopic and electrical assessment of implantable cardioverter-defibrillator patients implanted with silicone-polyurethane copolymer (Optim™) coated leads. Forleo GB; Di Biase L; Panattoni G; Politano A; Magliano G; Santini L; Natale A; Romeo F Europace; 2014 Feb; 16(2):265-70. PubMed ID: 24042736 [TBL] [Abstract][Full Text] [Related]
6. Failure-free survival of the Durata defibrillator lead. Liu J; Patel D; Rattan R; Brumberg G; Saini A; Vaghasia N; Bazaz R; Adelstein E; Jain S; Saba S Europace; 2013 Jul; 15(7):1002-6. PubMed ID: 23376976 [TBL] [Abstract][Full Text] [Related]
7. Insulation defects in Riata implantable cardioverter-defibrillator leads. Sato A; Chinushi M; Iijima K; Izumi D; Furushima H Intern Med; 2012; 51(19):2689-94. PubMed ID: 23037457 [TBL] [Abstract][Full Text] [Related]
8. Prevalence and predictors of cable extrusion and loss of electrical integrity with the Riata defibrillator lead. Shen S; Bhave P; Giedrimas E; Patel T; Arora R; Chicos AB; Goldberger JJ; Ilkhanoff L; Kim MH; Lin AC; Passman R; Lee R; Knight BP; Kim SS J Cardiovasc Electrophysiol; 2012 Nov; 23(11):1207-12. PubMed ID: 22697600 [TBL] [Abstract][Full Text] [Related]
9. High prevalence of insulation failure with externalized cables in St. Jude Medical Riata family ICD leads: fluoroscopic grading scale and correlation to extracted leads. Parvathaneni SV; Ellis CR; Rottman JN Heart Rhythm; 2012 Aug; 9(8):1218-24. PubMed ID: 22449742 [TBL] [Abstract][Full Text] [Related]
10. Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect. Hauser RG; McGriff D; Retel LK Heart Rhythm; 2012 May; 9(5):742-9. PubMed ID: 22209723 [TBL] [Abstract][Full Text] [Related]
11. Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors. Kodoth VN; Hodkinson EC; Noad RL; Ashfield KP; Cromie NA; McEneaney DJ; Wilson CM; Roberts MJ Pacing Clin Electrophysiol; 2012 Dec; 35(12):1498-504. PubMed ID: 23035735 [TBL] [Abstract][Full Text] [Related]
12. Long-term performance and lead failure analysis of the Durata defibrillation lead compared to its previous model, the recalled Riata defibrillation lead. Kleemann T; Nonnenmacher F; Strauss M; Kouraki K; Werner N; Fendt A; Zahn R J Cardiovasc Electrophysiol; 2019 Oct; 30(10):2012-2019. PubMed ID: 31332876 [TBL] [Abstract][Full Text] [Related]
13. Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family. Liu J; Rattan R; Adelstein E; Barrington W; Bazaz R; Brode S; Jain S; Mendenhall GS; Nemec J; Razak E; Shalaby A; Schwartzman D; Voigt A; Wang NC; Saba S Circ Arrhythm Electrophysiol; 2012 Aug; 5(4):809-14. PubMed ID: 22787015 [TBL] [Abstract][Full Text] [Related]
14. Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis. Pokorney SD; Zhou K; Matchar DB; Love S; Zeitler EP; Lewis R; Piccini JP J Cardiovasc Electrophysiol; 2015 Feb; 26(2):184-91. PubMed ID: 25311559 [TBL] [Abstract][Full Text] [Related]
15. Failure rate of the Riata lead under advisory: a report from the CHRS Device Committee. Parkash R; Exner D; Champagne J; Mangat I; Thibault B; Healey JS; Tung S; Crystal E; Simpson C; Nery PB; Sterns L; Connors S; Cameron D; Verma A; Beardsall M; Wolfe K; Essebag V; Ayala-Paredes F; Sanatani S; Coutu B; Fraser J; Toal S; Philippon F; Tang AS; Yee R; Krahn A Heart Rhythm; 2013 May; 10(5):692-5. PubMed ID: 23333722 [TBL] [Abstract][Full Text] [Related]
16. Timing of delayed perforation with the St. Jude Riata lead: a single-center experience and a review of the literature. Danik SB; Mansour M; Heist EK; Ellinor P; Milan D; Singh J; Das S; Reddy V; D'Avila A; Ruskin JN; Mela T Heart Rhythm; 2008 Dec; 5(12):1667-72. PubMed ID: 19084802 [TBL] [Abstract][Full Text] [Related]
17. Conductor externalization of the Riata internal cardioverter defibrillator lead: tip of the iceberg? Report of three cases and review of literature. Dorman HG; van Opstal JM; Stevenhagen J; Scholten MF Europace; 2012 Aug; 14(8):1161-4. PubMed ID: 22431444 [TBL] [Abstract][Full Text] [Related]
18. What did we learn from Riata™? Fischer A; Jenney C Herzschrittmacherther Elektrophysiol; 2015 Jun; 26(2):105-10. PubMed ID: 26054484 [TBL] [Abstract][Full Text] [Related]
19. A Comparative Study of Defibrillator Leads at a Large-Volume Implanting Hospital: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS"). Cohen TJ; Asheld WJ; Germano J; Islam S; Patel D J Invasive Cardiol; 2015 Jun; 27(6):292-300. PubMed ID: 26028656 [TBL] [Abstract][Full Text] [Related]
20. Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee. Theuns DA; Elvan A; de Voogt W; de Cock CC; van Erven L; Meine M Circ Arrhythm Electrophysiol; 2012 Dec; 5(6):1059-63. PubMed ID: 23091049 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]