These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 23123040)

  • 1. Do ion concentrations after metal-on-metal hip resurfacing increase over time? A prospective study.
    Amstutz HC; Campbell PA; Dorey FJ; Johnson AJ; Skipor AK; Jacobs JJ
    J Arthroplasty; 2013 Apr; 28(4):695-700. PubMed ID: 23123040
    [TBL] [Abstract][Full Text] [Related]  

  • 2. One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.
    Lardanchet JF; Taviaux J; Arnalsteen D; Gabrion A; Mertl P
    Orthop Traumatol Surg Res; 2012 May; 98(3):265-74. PubMed ID: 22480865
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris.
    Matharu GS; Berryman F; Brash L; Pynsent PB; Treacy RB; Dunlop DJ
    J Bone Joint Surg Am; 2016 Apr; 98(8):617-26. PubMed ID: 27098320
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cobalt and chromium levels in blood and urine following hip resurfacing arthroplasty with the Conserve Plus implant.
    Kim PR; Beaulé PE; Dunbar M; Lee JK; Birkett N; Turner MC; Yenugadhati N; Armstrong V; Krewski D
    J Bone Joint Surg Am; 2011 May; 93 Suppl 2():107-17. PubMed ID: 21543699
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metal ion levels in total hip arthroplasty versus hip resurfacing.
    Johnson AJ; Le Duff MJ; Yoon JP; Al-Hamad M; Amstutz HC
    J Arthroplasty; 2013 Aug; 28(7):1235-7. PubMed ID: 23618754
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cobalt and chromium ion release after large-diameter metal-on-metal total hip arthroplasty.
    Hasegawa M; Yoshida K; Wakabayashi H; Sudo A
    J Arthroplasty; 2012 Jun; 27(6):990-6. PubMed ID: 22325959
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
    Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
    ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Systemic toxicity related to metal hip prostheses.
    Bradberry SM; Wilkinson JM; Ferner RE
    Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Surveillance of Patients with Metal-on-Metal Hip Resurfacing and Total Hip Prostheses: A Prospective Cohort Study to Investigate the Relationship Between Blood Metal Ion Levels and Implant Failure.
    Hart AJ; Sabah SA; Sampson B; Skinner JA; Powell JJ; Palla L; Pajamäki KJ; Puolakka T; Reito A; Eskelinen A
    J Bone Joint Surg Am; 2014 Jul; 96(13):1091-1099. PubMed ID: 24990974
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.
    Antoniou J; Zukor DJ; Mwale F; Minarik W; Petit A; Huk OL
    J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():142-8. PubMed ID: 18676949
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants.
    Matharu GS; Berryman F; Judge A; Reito A; McConnell J; Lainiala O; Young S; Eskelinen A; Pandit HG; Murray DW
    J Bone Joint Surg Am; 2017 Sep; 99(18):1532-1539. PubMed ID: 28926382
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the method for analyzing chromium, cobalt and titanium ion levels in the blood following hip replacement with a metal-on-metal prosthesis.
    Barry J; Lavigne M; Vendittoli PA
    J Anal Toxicol; 2013 Mar; 37(2):90-6. PubMed ID: 23276726
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period.
    deSouza RM; Parsons NR; Oni T; Dalton P; Costa M; Krikler S
    J Bone Joint Surg Br; 2010 Dec; 92(12):1642-7. PubMed ID: 21119168
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study.
    Daniel J; Ziaee H; Pradhan C; Pynsent PB; McMinn DJ
    J Bone Joint Surg Br; 2007 Feb; 89(2):169-73. PubMed ID: 17322429
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.
    Vendittoli PA; Mottard S; Roy AG; Dupont C; Lavigne M
    J Bone Joint Surg Br; 2007 Apr; 89(4):441-8. PubMed ID: 17463109
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Serum metal ion concentrations after unilateral vs bilateral large-head metal-on-metal primary total hip arthroplasty.
    Pelt CE; Bergeson AG; Anderson LA; Stoddard GJ; Peters CL
    J Arthroplasty; 2011 Dec; 26(8):1494-500. PubMed ID: 21570800
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
    Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M
    J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study.
    Ziaee H; Daniel J; Datta AK; Blunt S; McMinn DJ
    J Bone Joint Surg Br; 2007 Mar; 89(3):301-5. PubMed ID: 17356138
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metal ion trend may be more predictive for malfunctioning metal-on-metal implants than a single measurement.
    Smolders JM; Hol A; van Susante JL
    Hip Int; 2013; 23(5):434-40. PubMed ID: 23934907
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.