BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 23124834)

  • 1. Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: preliminary findings.
    Cromer MS; Foster SL; Bourne RM; Fransen M; Fulton R; Wang SC
    J Magn Reson Imaging; 2013 Jul; 38(1):245-50. PubMed ID: 23124834
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3T.
    Kudo H; Inaoka T; Kitamura N; Nakatsuka T; Kasuya S; Kasai R; Tozawa M; Nakagawa K; Terada H
    Magn Reson Imaging; 2013 Oct; 31(8):1309-17. PubMed ID: 23684241
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional magnetic resonance observation of cartilage repair tissue (MOCART) score assessed with an isotropic three-dimensional true fast imaging with steady-state precession sequence at 3.0 Tesla.
    Welsch GH; Zak L; Mamisch TC; Resinger C; Marlovits S; Trattnig S
    Invest Radiol; 2009 Sep; 44(9):603-12. PubMed ID: 19692843
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): feasibility and reproducibility.
    Goebel JC; Bolbos R; Pinzano A; Schaeffer M; Rengle A; Galois L; Etienne S; Netter P; Loeuille D; Beuf O; Gillet P
    Biomed Mater Eng; 2008; 18(4-5):247-52. PubMed ID: 19065030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-resolution cartilage imaging of the knee at 3T: basic evaluation of modern isotropic 3D MR-sequences.
    Friedrich KM; Reiter G; Kaiser B; Mayerhöfer M; Deimling M; Jellus V; Horger W; Trattnig S; Schweitzer M; Salomonowitz E
    Eur J Radiol; 2011 Jun; 78(3):398-405. PubMed ID: 20138723
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy.
    Bauer JS; Krause SJ; Ross CJ; Krug R; Carballido-Gamio J; Ozhinsky E; Majumdar S; Link TM
    Radiology; 2006 Nov; 241(2):399-406. PubMed ID: 17057067
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MRI of the knee at 3T: first clinical results with an isotropic PDfs-weighted 3D-TSE-sequence.
    Notohamiprodjo M; Horng A; Pietschmann MF; Müller PE; Horger W; Park J; Crispin A; del Olmo JR; Weckbach S; Herrmann KA; Reiser MF; Glaser C
    Invest Radiol; 2009 Sep; 44(9):585-97. PubMed ID: 19668001
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Articular cartilage grading of the knee: diagnostic performance of fat-suppressed 3D volume isotropic turbo spin-echo acquisition (VISTA) compared with 3D T1 high-resolution isovolumetric examination (THRIVE).
    Lee YH; Hahn S; Lim D; Suh JS
    Acta Radiol; 2017 Feb; 58(2):190-196. PubMed ID: 27207633
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3T system scientific research.
    Milewski MD; Smitaman E; Moukaddam H; Katz LD; Essig DA; Medvecky MJ; Haims AH
    Eur J Radiol; 2012 Jul; 81(7):1637-43. PubMed ID: 21683539
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid 3D-T1rho mapping of the knee joint at 3.0T with parallel imaging.
    Pakin SK; Xu J; Schweitzer ME; Regatte RR
    Magn Reson Med; 2006 Sep; 56(3):563-71. PubMed ID: 16894582
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging.
    Eckstein F; Westhoff J; Sittek H; Maag KP; Haubner M; Faber S; Englmeier KH; Reiser M
    AJR Am J Roentgenol; 1998 Mar; 170(3):593-7. PubMed ID: 9490936
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantification of the volume of articular cartilage in the metacarpophalangeal joints of the hand: accuracy and precision of three-dimensional MR imaging.
    Peterfy CG; van Dijke CF; Lu Y; Nguyen A; Connick TJ; Kneeland JB; Tirman PF; Lang P; Dent S; Genant HK
    AJR Am J Roentgenol; 1995 Aug; 165(2):371-5. PubMed ID: 7618560
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multiplanar reconstruction recovers morphological cartilage assessment reproducibility from maloriented coronal MRI scans.
    Inglis D; Wong AK; Eckstein F; Adachi JD; Beattie KA
    Magn Reson Med; 2011 Mar; 65(3):790-5. PubMed ID: 20939062
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computer-aided method for quantification of cartilage thickness and volume changes using MRI: validation study using a synthetic model.
    Kauffmann C; Gravel P; Godbout B; Gravel A; Beaudoin G; Raynauld JP; Martel-Pelletier J; Pelletier JP; de Guise JA
    IEEE Trans Biomed Eng; 2003 Aug; 50(8):978-88. PubMed ID: 12892325
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3D-T1rho quantitation of patellar cartilage at 3.0T.
    Pakin SK; Schweitzer ME; Regatte RR
    J Magn Reson Imaging; 2006 Dec; 24(6):1357-63. PubMed ID: 17058202
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions.
    Li X; Yu C; Wu H; Daniel K; Hu D; Xia L; Pan C; Xu A; Hu J; Wang L; Peng W; Li F
    Clin Radiol; 2009 Oct; 64(10):1000-8. PubMed ID: 19748006
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-resolution 3D cartilage imaging with IDEAL SPGR at 3 T.
    Siepmann DB; McGovern J; Brittain JH; Reeder SB
    AJR Am J Roentgenol; 2007 Dec; 189(6):1510-5. PubMed ID: 18029893
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reproducibility and repeatability of volumetric measurements for olfactory bulb volumetry: which method is appropriate? An update using 3 Tesla MRI.
    Burmeister HP; Baltzer PA; Möslein C; Bitter T; Gudziol H; Dietzel M; Guntinas-Lichius O; Kaiser WA
    Acad Radiol; 2011 Jul; 18(7):842-9. PubMed ID: 21669350
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cartilage volume quantification via Live Wire segmentation.
    Gougoutas AJ; Wheaton AJ; Borthakur A; Shapiro EM; Kneeland JB; Udupa JK; Reddy R
    Acad Radiol; 2004 Dec; 11(12):1389-95. PubMed ID: 15596377
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automatic human knee cartilage segmentation from 3D magnetic resonance images.
    Dodin P; Pelletier JP; Martel-Pelletier J; Abram F
    IEEE Trans Biomed Eng; 2010 Nov; 57(11):. PubMed ID: 20639173
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.