These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

337 related articles for article (PubMed ID: 23126925)

  • 1. X-ray absorption spectroscopy of aluminum z-pinch plasma with tungsten backlighter planar wire array source.
    Osborne GC; Kantsyrev VL; Safronova AS; Esaulov AA; Weller ME; Shrestha I; Shlyaptseva VV; Ouart ND
    Rev Sci Instrum; 2012 Oct; 83(10):10E103. PubMed ID: 23126925
    [TBL] [Abstract][Full Text] [Related]  

  • 2. X-ray diagnostics of imploding plasmas from planar wire arrays composed of Cu and few tracer Al wires on the 1MA pulsed power generator at UNR.
    Safronova AS; Kantsyrev VL; Esaulov AA; Ouart ND; Yilmaz MF; Williamson KM; Shlyaptseva V; Shrestha I; Osborne GC; Coverdale CA; Jones B; Deeney C
    Rev Sci Instrum; 2008 Oct; 79(10):10E315. PubMed ID: 19044477
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multicolor, time-gated, soft x-ray pinhole imaging of wire array and gas puff Z pinches on the Z and Saturn pulsed power generators.
    Jones B; Coverdale CA; Nielsen DS; Jones MC; Deeney C; Serrano JD; Nielsen-Weber LB; Meyer CJ; Apruzese JP; Clark RW; Coleman PL
    Rev Sci Instrum; 2008 Oct; 79(10):10E906. PubMed ID: 19044561
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High resolution absorption spectroscopy of exploding wire plasmas using an x-pinch x-ray source and spherically bent crystal.
    Knapp PF; Pikuz SA; Shelkovenko TA; Hammer DA; Hansen SB
    Rev Sci Instrum; 2011 Jun; 82(6):063501. PubMed ID: 21721685
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A time-resolved spectroscopic diagnostic based on fast scintillator and optical fiber array for z-pinch plasmas.
    Ye F; Qin Y; Jiang S; Xue F; Li Z; Yang J; Xu R; Anan'ev SS; Dan'ko SA; Kalinin YG
    Rev Sci Instrum; 2009 Oct; 80(10):106105. PubMed ID: 19895094
    [TBL] [Abstract][Full Text] [Related]  

  • 6. K-shell emission x-ray imaging of Z-pinch plasmas with a pinhole and a logarithmic spiral crystal.
    Yang Q; Li Z; Peng Q; Yang L; Chen G; Ye Y; Huang X; Cai H; Li J; Xiao S
    Rev Sci Instrum; 2011 Sep; 82(9):093301. PubMed ID: 21974579
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Grazing incidence extreme ultraviolet spectrometer fielded with time resolution in a hostile z-pinch environment.
    Williamson KM; Kantsyrev VL; Safronova AS; Wilcox PG; Cline W; Batie S; LeGalloudec B; Nalajala V; Astanovitsky A
    Rev Sci Instrum; 2011 Sep; 82(9):093506. PubMed ID: 21974586
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic of charge balance in high-temperature tungsten plasmas using LLNL EBIT.
    Osborne GC; Safronova AS; Kantsyrev VL; Safronova UI; Yilmaz MF; Williamson KM; Shrestha I; Beiersdorfer P
    Rev Sci Instrum; 2008 Oct; 79(10):10E308. PubMed ID: 19044470
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characteristics and scaling of tungsten-wire-array z -pinch implosion dynamics at 20 MA.
    Cuneo ME; Waisman EM; Lebedev SV; Chittenden JP; Stygar WA; Chandler GA; Vesey RA; Yu EP; Nash TJ; Bliss DE; Sarkisov GS; Wagoner TC; Bennett GR; Sinars DB; Porter JL; Simpson WW; Ruggles LE; Wenger DF; Garasi CJ; Oliver BV; Aragon RA; Fowler WE; Hettrick MC; Idzorek GC; Johnson D; Keller K; Lazier SE; McGurn JS; Mehlhorn TA; Moore T; Nielsen DS; Pyle J; Speas S; Struve KW; Torres JA
    Phys Rev E Stat Nonlin Soft Matter Phys; 2005 Apr; 71(4 Pt 2):046406. PubMed ID: 15903793
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnosis of x-ray heated Mg/Fe opacity research plasmas.
    Bailey JE; Rochau GA; Mancini RC; Iglesias CA; MacFarlane JJ; Golovkin IE; Pain JC; Gilleron F; Blancard C; Cosse P; Faussurier G; Chandler GA; Nash TJ; Nielsen DS; Lake PW
    Rev Sci Instrum; 2008 Nov; 79(11):113104. PubMed ID: 19045886
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatially resolved single crystal x-ray spectropolarimetry of wire array z-pinch plasmas.
    Wallace MS; Haque S; Neill P; Pereira NR; Presura R
    Rev Sci Instrum; 2018 Jan; 89(1):015106. PubMed ID: 29390728
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of the ionization state and electron temperature of plasma during the ablation stage of a wire-array Z pinch using absorption spectroscopy.
    Ivanov VV; Hakel P; Mancini RC; Chittenden JP; Anderson A; Durmaz T; Wiewior P; Papp D; Altemara SD; Astanovitskiy AL; Chalyy O
    Phys Rev Lett; 2011 Jun; 106(22):225005. PubMed ID: 21702609
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Observation of >400-eV precursor plasmas from low-wire-number copper arrays at the 1-MA zebra facility.
    Coverdale CA; Safronova AS; Kantsyrev VL; Ouart ND; Esaulov AA; Deeney C; Williamson KM; Osborne GC; Shrestha I; Ampleford DJ; Jones B
    Phys Rev Lett; 2009 Apr; 102(15):155006. PubMed ID: 19518644
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Picosecond time-resolved X-ray absorption spectroscopy of ultrafast aluminum plasmas.
    Audebert P; Renaudin P; Bastiani-Ceccotti S; Geindre JP; Chenais-Popovics C; Tzortzakis S; Nagels-Silvert V; Shepherd R; Matsushima I; Gary S; Girard F; Peyrusse O; Gauthier JC
    Phys Rev Lett; 2005 Jan; 94(2):025004. PubMed ID: 15698184
    [TBL] [Abstract][Full Text] [Related]  

  • 15. X-ray spectroscopy of Cu impurities on NSTX and comparison with Z-pinch plasmas.
    Safronova AS; Ouart ND; Lepson JK; Beiersdorfer P; Stratton B; Bitter M; Kantsyrev VL; Cox PG; Shlyaptseva V; Williamson KM
    Rev Sci Instrum; 2010 Oct; 81(10):10E305. PubMed ID: 21034004
    [TBL] [Abstract][Full Text] [Related]  

  • 16. X-ray emission from z pinches at 10 7 A: current scaling, gap closure, and shot-to-shot fluctuations.
    Stygar WA; Ives HC; Fehl DL; Cuneo ME; Mazarakis MG; Bailey JE; Bennett GR; Bliss DE; Chandler GA; Leeper RJ; Matzen MK; McDaniel DH; McGurn JS; McKenney JL; Mix LP; Muron DJ; Porter JL; Ramirez JJ; Ruggles LE; Seamen JF; Simpson WW; Speas CS; Spielman RB; Struve KW; Torres JA; Vesey RA; Wagoner TC; Gilliland TL; Horry ML; Jobe DO; Lazier SE; Mills JA; Mulville TD; Pyle JH; Romero TM; Seamen JJ; Smelser RM
    Phys Rev E Stat Nonlin Soft Matter Phys; 2004 Apr; 69(4 Pt 2):046403. PubMed ID: 15169102
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Double conical crystal x-ray spectrometer for high resolution ultrafast x-ray absorption near-edge spectroscopy of Al K edge.
    Levy A; Dorchies F; Fourment C; Harmand M; Hulin S; Santos JJ; Descamps D; Petit S; Bouillaud R
    Rev Sci Instrum; 2010 Jun; 81(6):063107. PubMed ID: 20590225
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A dual-channel, curved-crystal spectrograph for petawatt laser, x-ray backlighter source studies.
    Theobald W; Stoeckl C; Jaanimagi PA; Nilson PM; Storm M; Meyerhofer DD; Sangster TC; Hey D; MacKinnon AJ; Park HS; Patel PK; Shepherd R; Snavely RA; Key MH; King JA; Zhang B; Stephens RB; Akli KU; Highbarger K; Daskalova RL; Van Woerkom L; Freeman RR; Green JS; Gregori G; Lancaster K; Norreys PA
    Rev Sci Instrum; 2009 Aug; 80(8):083501. PubMed ID: 19725649
    [TBL] [Abstract][Full Text] [Related]  

  • 19. X-ray absorption spectroscopy measurements of thin foil heating by Z-pinch radiation.
    MacFarlane JJ; Bailey JE; Chandler GA; Deeney C; Douglas MR; Jobe D; Lake P; Nash TJ; Nielsen DS; Spielman RB; Wang P; Woodruff P
    Phys Rev E Stat Nonlin Soft Matter Phys; 2002 Oct; 66(4 Pt 2):046416. PubMed ID: 12443339
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 2-20 ns interframe time 2-frame 6.151 keV x-ray imaging on the recently upgraded Z Accelerator: a progress report.
    Bennett GR; Smith IC; Shores JE; Sinars DB; Robertson G; Atherton BW; Jones MC; Porter JL
    Rev Sci Instrum; 2008 Oct; 79(10):10E914. PubMed ID: 19044569
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.