These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 23126978)

  • 1. Collinearity alignment of probe beams in a laser-based Faraday effect diagnostic.
    Lin L; Ding WX; Brower DL
    Rev Sci Instrum; 2012 Oct; 83(10):10E320. PubMed ID: 23126978
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design of a millimeter-wave polarimeter for NSTX-Upgrade and initial test on DIII-D.
    Zhang J; Peebles WA; Carter TA; Crocker NA; Doyle EJ; Kubota S; Nguyen X; Rhodes TL; Wannberg C; Zeng L
    Rev Sci Instrum; 2012 Oct; 83(10):10E321. PubMed ID: 23126979
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First results from the J-TEXT high-resolution three-wave polarimeter-interferometer.
    Chen J; Zhuang G; Wang ZJ; Gao L; Li Q; Chen W; Brower DL; Ding WX
    Rev Sci Instrum; 2012 Oct; 83(10):10E306. PubMed ID: 23126966
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 2D image of local density and magnetic fluctuations from line-integrated interferometry-polarimetry measurements.
    Lin L; Ding WX; Brower DL
    Rev Sci Instrum; 2014 Nov; 85(11):11D403. PubMed ID: 25430166
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak (invited).
    Chen J; Zhuang G; Li Q; Liu Y; Gao L; Zhou YN; Jian X; Xiong CY; Wang ZJ; Brower DL; Ding WX
    Rev Sci Instrum; 2014 Nov; 85(11):11D303. PubMed ID: 25430163
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D.
    Chen J; Ding WX; Brower DL; Finkenthal D; Boivin R
    Rev Sci Instrum; 2018 Oct; 89(10):10B101. PubMed ID: 30399782
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Differential interferometry for measurement of density fluctuations and fluctuation-induced transport (invited).
    Lin L; Ding WX; Brower DL; Bergerson WF; Yates TF
    Rev Sci Instrum; 2010 Oct; 81(10):10D509. PubMed ID: 21033864
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Upgrade of far-infrared laser-based Faraday rotation measurement on MST.
    Ding WX; Brower DL; Bergerson WF; Lin L
    Rev Sci Instrum; 2010 Oct; 81(10):10D508. PubMed ID: 21033863
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of ion collection area in Faraday probes.
    Brown DL; Gallimore AD
    Rev Sci Instrum; 2010 Jun; 81(6):063504. PubMed ID: 20590238
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Theoretical and numerical evaluation of polarimeter using counter-circularly-polarized-probing-laser under the coupling between Faraday and Cotton-Mouton effect.
    Imazawa R; Kawano Y; Itami K
    Rev Sci Instrum; 2016 Apr; 87(4):043512. PubMed ID: 27131679
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-frequency fluctuation measurements by far-infrared laser Faraday-effect polarimetry-interferometry and forward scattering system on MST.
    Ding WX; Lin L; Duff JR; Brower DL
    Rev Sci Instrum; 2014 Nov; 85(11):11D406. PubMed ID: 25430169
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Self-referenced rectangular path cyclic interferometer with polarization phase shifting.
    Sarkar S; Ghosh N; Chakraborty S; Bhattacharya K
    Appl Opt; 2012 Jan; 51(1):126-32. PubMed ID: 22270421
    [TBL] [Abstract][Full Text] [Related]  

  • 13. CO2 laser polarimeter for Faraday rotation measurements in the DIII-D tokamak.
    Van Zeeland MA; Boivin RL; Carlstrom TN; Deterly TM
    Rev Sci Instrum; 2008 Oct; 79(10):10E719. PubMed ID: 19044536
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Polarimeter for the General Fusion SPECTOR machine.
    Carle P; Froese A; Wong A; Howard S; O'Shea P; Laberge M
    Rev Sci Instrum; 2016 Nov; 87(11):11E104. PubMed ID: 27910315
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Far-infrared polarimetry diagnostic for measurement of internal magnetic field dynamics and fluctuations in the C-MOD Tokamak (invited).
    Bergerson WF; Xu P; Irby JH; Brower DL; Ding WX; Marmar ES
    Rev Sci Instrum; 2012 Oct; 83(10):10E316. PubMed ID: 23126975
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-channel far-infrared HL-2A interferometer-polarimeter.
    Zhou Y; Deng ZC; Li YG; Yi J
    Rev Sci Instrum; 2012 Oct; 83(10):10E336. PubMed ID: 23126994
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simple and sensitive technique for alignment of the pinhole of a spatial filter of a high-energy, high-power laser system.
    Sharma AK; Patidar RK; Daiya D; Joshi A; Naik PA; Gupta PD
    Appl Opt; 2013 Apr; 52(12):2546-54. PubMed ID: 23669660
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge.
    Chen J; Brower DL; Benedett T
    Rev Sci Instrum; 2022 Aug; 93(8):083515. PubMed ID: 36050047
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design of far-infrared three-wave polarimeter-interferometer system for the J-TEXT tokamak.
    Chen J; Gao L; Zhuang G; Wang ZJ; Gentle KW
    Rev Sci Instrum; 2010 Oct; 81(10):10D502. PubMed ID: 21033857
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Weak value amplification of an optical Faraday differential refraction effect.
    Parks AD; Spence SE
    Appl Opt; 2012 Jun; 51(16):3364-9. PubMed ID: 22695571
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.