These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 23127052)

  • 21. Polymer gel dosimetry on a multislice computed tomography scanner: effect of changing parameters on CTDI.
    Hill B; Venning AJ; Baldock C
    Phys Med; 2008 Sep; 24(3):149-58. PubMed ID: 18289906
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Radiation dosimetry for electron beam CT.
    McCollough CH; Zink FE; Morin RL
    Radiology; 1994 Sep; 192(3):637-43. PubMed ID: 8058927
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A radiation exposure index for CT.
    Huda W
    Radiat Prot Dosimetry; 2013 Dec; 157(2):172-80. PubMed ID: 23690648
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT.
    Hupfer M; Kolditz D; Nowak T; Eisa F; Brauweiler R; Kalender WA
    Med Phys; 2012 Feb; 39(2):658-70. PubMed ID: 22320775
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners.
    Hill B; Venning AJ; Baldock C
    Med Phys; 2005 Jun; 32(6):1589-97. PubMed ID: 16013718
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Estimation of the weighted CTDI(∞) for multislice CT examinations.
    Li X; Zhang D; Liu B
    Med Phys; 2012 Feb; 39(2):901-5. PubMed ID: 22320799
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Radiotherapy dosimetry using a commercial OSL system.
    Viamonte A; da Rosa LA; Buckley LA; Cherpak A; Cygler JE
    Med Phys; 2008 Apr; 35(4):1261-6. PubMed ID: 18491518
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures.
    Ding GX; Malcolm AW
    Phys Med Biol; 2013 Sep; 58(17):5885-97. PubMed ID: 23920245
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging.
    Gomà C; Ruiz A; Jornet N; Latorre A; Pallerol RM; Carrasco P; Eudaldo T; Ribas M
    Med Phys; 2011 Mar; 38(3):1473-80. PubMed ID: 21520859
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.
    Mrčela I; Bokulić T; Izewska J; Budanec M; Fröbe A; Kusić Z
    Phys Med Biol; 2011 Sep; 56(18):6065-82. PubMed ID: 21873767
    [TBL] [Abstract][Full Text] [Related]  

  • 31. CT dosimetry: comparison of measurement techniques and devices.
    Bauhs JA; Vrieze TJ; Primak AN; Bruesewitz MR; McCollough CH
    Radiographics; 2008; 28(1):245-53. PubMed ID: 18203941
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams.
    Kerns JR; Kry SF; Sahoo N
    Med Phys; 2012 Apr; 39(4):1854-63. PubMed ID: 22482607
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Calibration and time fading characterization of a new optically stimulated luminescence film dosimeter.
    Caprioli M; Delombaerde L; De Saint-Hubert M; de Freitas Nascimento L; De Roover R; Himschoot K; van der Heyden B; Vandenbroucke D; Leblans P; Crijns W
    Med Phys; 2023 Feb; 50(2):1185-1193. PubMed ID: 36353946
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On the length used for CT ionization chambers to determine CTDI.
    DeWerd LA; Khan AU; Jensen AR
    Phys Med Biol; 2022 Apr; 67(8):. PubMed ID: 35325885
    [No Abstract]   [Full Text] [Related]  

  • 35. Cone beam CT dosimetry: a unified and self-consistent approach including all scan modalities--with or without phantom motion.
    Dixon RL; Boone JM
    Med Phys; 2010 Jun; 37(6):2703-18. PubMed ID: 20632581
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Characterization of the nanoDot OSLD dosimeter in CT.
    Scarboro SB; Cody D; Alvarez P; Followill D; Court L; Stingo FC; Zhang D; McNitt-Gray M; Kry SF
    Med Phys; 2015 Apr; 42(4):1797-807. PubMed ID: 25832070
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
    Schembri V; Heijmen BJ
    Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vitro dose measurements in a human cadaver with abdomen/pelvis CT scans.
    Zhang D; Padole A; Li X; Singh S; Khawaja RD; Lira D; Liu T; Shi JQ; Otrakji A; Kalra MK; Xu XG; Liu B
    Med Phys; 2014 Sep; 41(9):091911. PubMed ID: 25186398
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.
    Jarry G; DeMarco JJ; Beifuss U; Cagnon CH; McNitt-Gray MF
    Phys Med Biol; 2003 Aug; 48(16):2645-63. PubMed ID: 12974580
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Relationship between radiographic techniques (kilovolt and milliampere-second) and CTDI(VOL).
    Elojeimy S; Tipnis S; Huda W
    Radiat Prot Dosimetry; 2010 Sep; 141(1):43-9. PubMed ID: 20406742
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.