21. Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators.
Beyer GP
J Appl Clin Med Phys; 2013 Jan; 14(1):4077. PubMed ID: 23318395
[TBL] [Abstract][Full Text] [Related]
22. Flattening filter free beams from TrueBeam and Versa HD units: Evaluation of the parameters for quality assurance.
Fogliata A; Fleckenstein J; Schneider F; Pachoud M; Ghandour S; Krauss H; Reggiori G; Stravato A; Lohr F; Scorsetti M; Cozzi L
Med Phys; 2016 Jan; 43(1):205. PubMed ID: 26745913
[TBL] [Abstract][Full Text] [Related]
23. An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams.
Chung H; Prado KL; Yi BY
Phys Med Biol; 2014 Feb; 59(4):951-60. PubMed ID: 24503449
[TBL] [Abstract][Full Text] [Related]
24. Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes.
Saenz DL; Narayanasamy G; Cruz W; Papanikolaou N; Stathakis S
J Appl Clin Med Phys; 2016 Jan; 17(1):192-206. PubMed ID: 26894352
[TBL] [Abstract][Full Text] [Related]
25. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
Almberg SS; Frengen J; Lindmo T
Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
[TBL] [Abstract][Full Text] [Related]
26. Characteristics of a novel treatment system for linear accelerator-based stereotactic radiosurgery.
Wen N; Li H; Song K; Chin-Snyder K; Qin Y; Kim J; Bellon M; Gulam M; Gardner S; Doemer A; Devpura S; Gordon J; Chetty I; Siddiqui F; Ajlouni M; Pompa R; Hammoud Z; Simoff M; Kalkanis S; Movsas B; Siddiqui MS
J Appl Clin Med Phys; 2015 Jul; 16(4):125–148. PubMed ID: 26218998
[TBL] [Abstract][Full Text] [Related]
27. Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.
Hoffman D; Chung E; Hess C; Stern R; Benedict S
J Appl Clin Med Phys; 2017 Jan; 18(1):40-48. PubMed ID: 28291937
[TBL] [Abstract][Full Text] [Related]
28. Technical Note: Preferred dosimeter size and associated correction factors in commissioning high dose per pulse, flattening filter free x-ray beams.
Sudhyadhom A; Kirby N; Faddegon B; Chuang CF
Med Phys; 2016 Mar; 43(3):1507-13. PubMed ID: 26936734
[TBL] [Abstract][Full Text] [Related]
29. Field correction factors for a PTW-31016 Pinpoint ionization chamber for both flattened and unflattened beams. Study of the main sources of uncertainties.
Puxeu-Vaqué J; Duch MA; Nailon WH; Cruz Lizuain M; Ginjaume M
Med Phys; 2017 May; 44(5):1930-1938. PubMed ID: 28261817
[TBL] [Abstract][Full Text] [Related]
30. Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams.
Kuess P; Georg D; Palmans H; Lechner W
Med Phys; 2016 Aug; 43(8):4507. PubMed ID: 27487867
[TBL] [Abstract][Full Text] [Related]
31. [Measurement of peak correction factor of Farmer chamber for calibration of flattening filter free (FFF) clinical photon beams].
Kontra G; Major T; Polgár C
Magy Onkol; 2015 Jun; 59(2):119-23. PubMed ID: 26035159
[TBL] [Abstract][Full Text] [Related]
32. Development of a fast and feasible spectrum modeling technique for flattening filter free beams.
Cho W; Bush K; Mok E; Xing L; Suh TS
Med Phys; 2013 Apr; 40(4):041721. PubMed ID: 23556891
[TBL] [Abstract][Full Text] [Related]
33. Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system.
Li J; Wiersma RD; Stepaniak CJ; Farrey KJ; Al-Hallaq HA
Med Phys; 2012 May; 39(5):2456-62. PubMed ID: 22559616
[TBL] [Abstract][Full Text] [Related]
34. Superficial and peripheral dose in compensator-based FFF beam IMRT.
Zhang DG; Feygelman V; Moros EG; Latifi K; Hoffe S; Frakes J; Zhang GG
J Appl Clin Med Phys; 2017 Jan; 18(1):151-156. PubMed ID: 28291940
[TBL] [Abstract][Full Text] [Related]
35. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
[TBL] [Abstract][Full Text] [Related]
36. Ion recombination corrections of ionization chambers in flattening filter-free photon radiation.
Wang Y; Easterling SB; Ting JY
J Appl Clin Med Phys; 2012 Sep; 13(5):3758. PubMed ID: 22955642
[TBL] [Abstract][Full Text] [Related]
37. Monte Carlo comparison of superficial dose between flattening filter free and flattened beams.
Javedan K; Feygelman V; Zhang RR; Moros EG; Correa CR; Trotti A; Li W; Zhang GG
Phys Med; 2014 Jun; 30(4):503-8. PubMed ID: 24662096
[TBL] [Abstract][Full Text] [Related]
38. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
[TBL] [Abstract][Full Text] [Related]
39. Effects of flattening filter-free and volumetric-modulated arc therapy delivery on treatment efficiency.
Thomas EM; Popple RA; Prendergast BM; Clark GM; Dobelbower MC; Fiveash JB
J Appl Clin Med Phys; 2013 Nov; 14(6):4328. PubMed ID: 24257275
[TBL] [Abstract][Full Text] [Related]
40. Radiation therapy with unflattened photon beams: dosimetric accuracy of advanced dose calculation algorithms.
Kragl G; Albrich D; Georg D
Radiother Oncol; 2011 Sep; 100(3):417-23. PubMed ID: 21945857
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]