These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 2312759)

  • 1. Automated measurement of plasma viscosity using the Coulter Viscometer II.
    Darwood S; Lines RW
    J Clin Pathol; 1990 Jan; 43(1):86. PubMed ID: 2312759
    [No Abstract]   [Full Text] [Related]  

  • 2. Automated measurement of plasma viscosity by capillary viscometer.
    Cooke BM; Stuart J
    J Clin Pathol; 1988 Nov; 41(11):1213-6. PubMed ID: 2463273
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The capillary tube plasma viscometer--an automatical instrument for measuring plasma viscosity.
    Jung F; Roggenkamp HG; Körber N; Schneider R; Kiesewetter H
    Biorheology Suppl; 1984; 1():115-7. PubMed ID: 6591963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate.
    Kim BJ; Lee SY; Jee S; Atajanov A; Yang S
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28632151
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated measurement of plasma viscosity by capillary viscometer.
    Fish DI; Jackson RF; Dawson DW
    J Clin Pathol; 1989 Jul; 42(7):780. PubMed ID: 2760241
    [No Abstract]   [Full Text] [Related]  

  • 6. Measurement of whole blood viscosity profiles via an automated viscometer: technical details and clinical relevance.
    Alexy T; Pais E; Wenby RB; Hogenauer W; Toth K; Meiselman HJ; Kensey KR
    Clin Lab; 2005; 51(9-10):523-9. PubMed ID: 16285475
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of blood viscosity using a pressure-scanning capillary viscometer.
    Shin S; Ku Y; Park MS; Suh JS
    Clin Hemorheol Microcirc; 2004; 30(3-4):467-70. PubMed ID: 15258389
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A highly accurate and consistent microfluidic viscometer for continuous blood viscosity measurement.
    Kang YJ; Yoon SY; Lee KH; Yang S
    Artif Organs; 2010 Nov; 34(11):944-9. PubMed ID: 20946281
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nanoliter viscometer for analyzing blood plasma and other liquid samples.
    Srivastava N; Davenport RD; Burns MA
    Anal Chem; 2005 Jan; 77(2):383-92. PubMed ID: 15649032
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new simple cone-plate viscometer for hemorheology.
    Wang X; Liao FL; Stoltz JF
    Clin Hemorheol Microcirc; 1998 Sep; 19(1):25-31. PubMed ID: 9806730
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rheologic measurements on small samples with a new capillary viscometer.
    Reinhart WH; Danoff SJ; Usami S; Chien S
    J Lab Clin Med; 1984 Dec; 104(6):921-31. PubMed ID: 6438260
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical laboratory measurement of serum, plasma, and blood viscosity.
    Rosencranz R; Bogen SA
    Am J Clin Pathol; 2006 Jun; 125 Suppl():S78-86. PubMed ID: 16830959
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rheological properties of blood as assessed with a newly designed oscillating viscometer.
    Reinhart WH; Häusler K; Schaller P; Erhart S; Stetter M; Dual J; Sayir M
    Clin Hemorheol Microcirc; 1998 Apr; 18(1):59-65. PubMed ID: 9653587
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new capillary viscometer for small samples of whole blood.
    Marinakis GN; Barbenel JC; Tsangaris SG
    Proc Inst Mech Eng H; 2002; 216(6):385-92. PubMed ID: 12502002
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of rheologic property of blood by a falling-ball blood viscometer.
    Eguchi Y; Karino T
    Ann Biomed Eng; 2008 Apr; 36(4):545-53. PubMed ID: 18259867
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of human blood viscosity by an electromagnetic spinning sphere viscometer.
    Furukawa K; Abumiya T; Sakai K; Hirano M; Osanai T; Shichinohe H; Nakayama N; Kazumata K; Aida T; Houkin K
    J Med Eng Technol; 2016 Aug; 40(6):285-92. PubMed ID: 27167739
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical performance evaluation of the scanning capillary tube viscometer for measurement of whole blood viscosity.
    Kim H; Cho YI; Lee DH; Park CM; Moon HW; Hur M; Kim JQ; Yun YM
    Clin Biochem; 2013 Jan; 46(1-2):139-42. PubMed ID: 23099199
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A tentative analysis on the principle of capillary tube viscometer].
    Qin R; Liang Y; Zhang Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Oct; 26(5):992-5. PubMed ID: 19947475
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The development of a new viscometer using hollow PVA fibers and its application for human plasma viscosity].
    Tsuji T; Togawa T; Muneoka K; Okamoto M
    Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1986; 20():105-9. PubMed ID: 3506223
    [No Abstract]   [Full Text] [Related]  

  • 20. Comparison of blood viscosity using a torsional oscillation viscometer and a rheometer.
    Travagli V; Zanardi I; Boschi L; Gabbrielli A; Mastronuzzi VA; Cappelli R; Forconi S
    Clin Hemorheol Microcirc; 2008; 38(2):65-74. PubMed ID: 18198407
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.