413 related articles for article (PubMed ID: 23127632)
1. Carbon fiber reinforced PEEK Optima--a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants.
Steinberg EL; Rath E; Shlaifer A; Chechik O; Maman E; Salai M
J Mech Behav Biomed Mater; 2013 Jan; 17():221-8. PubMed ID: 23127632
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.
Mugnai R; Tarallo L; Capra F; Catani F
Orthop Traumatol Surg Res; 2018 Oct; 104(6):877-882. PubMed ID: 29807189
[TBL] [Abstract][Full Text] [Related]
3. A biomechanical matched-pair comparison of two different locking plates for tibial diaphyseal comminuted fracture: carbon fiber-reinforced poly-ether-ether-ketone (CF-PEEK) versus titanium plates.
Zhou K; He X; Tao X; Pan F; Yang H
J Orthop Surg Res; 2020 Nov; 15(1):558. PubMed ID: 33228695
[TBL] [Abstract][Full Text] [Related]
4. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures.
Katthagen JC; Schwarze M; Warnhoff M; Voigt C; Hurschler C; Lill H
Injury; 2016 Mar; 47(3):617-24. PubMed ID: 26804939
[TBL] [Abstract][Full Text] [Related]
5. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.
Schliemann B; Seifert R; Theisen C; Gehweiler D; Wähnert D; Schulze M; Raschke MJ; Weimann A
Arch Orthop Trauma Surg; 2017 Jan; 137(1):63-71. PubMed ID: 28005168
[TBL] [Abstract][Full Text] [Related]
6. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.
Hak DJ; Fader R; Baldini T; Chadayammuri VBS
Int Orthop; 2017 Sep; 41(9):1735-1739. PubMed ID: 28707049
[TBL] [Abstract][Full Text] [Related]
7. Finite element investigation into the use of carbon fibre reinforced PEEK laminated composites for distal radius fracture fixation implants.
Gallagher EA; Lamorinière S; McGarry P
Med Eng Phys; 2019 May; 67():22-32. PubMed ID: 30879944
[TBL] [Abstract][Full Text] [Related]
8. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.
de Jong JJ; Lataster A; van Rietbergen B; Arts JJ; Geusens PP; van den Bergh JP; Willems PC
BMC Med Imaging; 2017 Feb; 17(1):18. PubMed ID: 28241752
[TBL] [Abstract][Full Text] [Related]
9. Mechanical properties, hemocompatibility, cytotoxicity and systemic toxicity of carbon fibers/poly(ether-ether-ketone) composites with different fiber lengths as orthopedic implants.
Li Y; Wang D; Qin W; Jia H; Wu Y; Ma J; Tang B
J Biomater Sci Polym Ed; 2019 Dec; 30(18):1709-1724. PubMed ID: 31464157
[TBL] [Abstract][Full Text] [Related]
10. Perturbation effects of the carbon fiber-PEEK screws on radiotherapy dose distribution.
Nevelsky A; Borzov E; Daniel S; Bar-Deroma R
J Appl Clin Med Phys; 2017 Mar; 18(2):62-68. PubMed ID: 28300369
[TBL] [Abstract][Full Text] [Related]
11. Titanium vs. carbon fiber-reinforced intramedullary nailing for humeral bone tumors.
Bhashyam AR; Yeung C; Sodhi A; Xu RF; Groot OQ; Kelly S; Lozano-Calderon S
J Shoulder Elbow Surg; 2023 Nov; 32(11):2286-2295. PubMed ID: 37263478
[TBL] [Abstract][Full Text] [Related]
12. Total knee arthroplasty application of polyetheretherketone and carbon-fiber-reinforced polyetheretherketone: A review.
Koh YG; Park KM; Lee JA; Nam JH; Lee HY; Kang KT
Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():70-81. PubMed ID: 30948107
[TBL] [Abstract][Full Text] [Related]
13. [Fixed angle carbon fiber reinforced polymer composite plate for treatment of distal radius fractures : Pilot study on clinical applications].
Behrendt P; Kruse E; Klüter T; Fitschen-Oestern S; Weuster M; Menzdorf L; Finn J; Varoga D; Seekamp A; Müller M; Lippross S
Unfallchirurg; 2017 Feb; 120(2):139-146. PubMed ID: 26507986
[TBL] [Abstract][Full Text] [Related]
14. Feasibility of knitted carbon/PEEK composites for orthopedic bone plates.
Fujihara K; Huang ZM; Ramakrishna S; Satknanantham K; Hamada H
Biomaterials; 2004 Aug; 25(17):3877-85. PubMed ID: 15020164
[TBL] [Abstract][Full Text] [Related]
15. The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine.
Scholes SC; Unsworth A
Proc Inst Mech Eng H; 2007 Apr; 221(3):281-9. PubMed ID: 17539583
[TBL] [Abstract][Full Text] [Related]
16. Coating of carbon fiber-reinforced polyetheretherketone implants with titanium to improve bone apposition.
Devine DM; Hahn J; Richards RG; Gruner H; Wieling R; Pearce SG
J Biomed Mater Res B Appl Biomater; 2013 May; 101(4):591-8. PubMed ID: 23281249
[TBL] [Abstract][Full Text] [Related]
17. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone.
Neumann EA; Villar CC; França FM
Braz Oral Res; 2014; 28():. PubMed ID: 25098826
[TBL] [Abstract][Full Text] [Related]
18. Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials.
Scholes SC; Unsworth A
J Mater Sci Mater Med; 2009 Jan; 20(1):163-70. PubMed ID: 18704647
[TBL] [Abstract][Full Text] [Related]
19. Feasibility of carbon-fiber-reinforced polymer fixation plates for treatment of atrophic mandibular fracture: A finite element method.
Nurettin D; Burak B
J Craniomaxillofac Surg; 2018 Dec; 46(12):2182-2189. PubMed ID: 30340836
[TBL] [Abstract][Full Text] [Related]
20. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.
Rezaei F; Hassani K; Solhjoei N; Karimi A
Australas Phys Eng Sci Med; 2015 Dec; 38(4):569-80. PubMed ID: 26462678
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]