These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
374 related articles for article (PubMed ID: 23128363)
21. Investigation of EEG and MEG source imaging accuracy in reconstructing extended cortical sources. Ding L; Yuan H Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():7013-6. PubMed ID: 22255953 [TBL] [Abstract][Full Text] [Related]
22. Time-coherent expansion of MEG/EEG cortical sources. David O; Garnero L Neuroimage; 2002 Nov; 17(3):1277-89. PubMed ID: 12414267 [TBL] [Abstract][Full Text] [Related]
23. Multivariate reconstruction of functional networks from cortical sources dynamics in MEG/EEG. Dossevi A; Cosmelli D; Garnero L; Ammari H IEEE Trans Biomed Eng; 2008 Aug; 55(8):2074-86. PubMed ID: 18632370 [TBL] [Abstract][Full Text] [Related]
24. MNE software for processing MEG and EEG data. Gramfort A; Luessi M; Larson E; Engemann DA; Strohmeier D; Brodbeck C; Parkkonen L; Hämäläinen MS Neuroimage; 2014 Feb; 86():446-60. PubMed ID: 24161808 [TBL] [Abstract][Full Text] [Related]
25. [Investigation of the Cerebral Cortex Using Magnetoencephalography(MEG)]. Kakigi R Brain Nerve; 2015 Apr; 67(4):451-66. PubMed ID: 25846594 [TBL] [Abstract][Full Text] [Related]
26. Using neuroimaging to understand the cortical mechanisms of auditory selective attention. Lee AK; Larson E; Maddox RK; Shinn-Cunningham BG Hear Res; 2014 Jan; 307():111-20. PubMed ID: 23850664 [TBL] [Abstract][Full Text] [Related]
27. Cortical Signal Suppression (CSS) for Detection of Subcortical Activity Using MEG and EEG. Samuelsson JG; Khan S; Sundaram P; Peled N; Hämäläinen MS Brain Topogr; 2019 Mar; 32(2):215-228. PubMed ID: 30604048 [TBL] [Abstract][Full Text] [Related]
29. MEG and TMS combined with EEG for mapping alcohol effects. Kähkönen S Alcohol; 2005 Nov; 37(3):129-33. PubMed ID: 16713500 [TBL] [Abstract][Full Text] [Related]
30. EEG minimum-norm estimation compared with MEG dipole fitting in the localization of somatosensory sources at S1. Komssi S; Huttunen J; Aronen HJ; Ilmoniemi RJ Clin Neurophysiol; 2004 Mar; 115(3):534-42. PubMed ID: 15036048 [TBL] [Abstract][Full Text] [Related]
31. Distributed current estimates using cortical orientation constraints. Lin FH; Belliveau JW; Dale AM; Hämäläinen MS Hum Brain Mapp; 2006 Jan; 27(1):1-13. PubMed ID: 16082624 [TBL] [Abstract][Full Text] [Related]
32. Sparse weightings for collapsing inverse solutions to cortical parcellations optimize M/EEG source reconstruction accuracy. Korhonen O; Palva S; Palva JM J Neurosci Methods; 2014 Apr; 226():147-160. PubMed ID: 24509129 [TBL] [Abstract][Full Text] [Related]
34. Multimodal integration of EEG and MEG data: a simulation study with variable signal-to-noise ratio and number of sensors. Babiloni F; Babiloni C; Carducci F; Romani GL; Rossini PM; Angelone LM; Cincotti F Hum Brain Mapp; 2004 May; 22(1):52-62. PubMed ID: 15083526 [TBL] [Abstract][Full Text] [Related]
35. Simultaneous EEG and MEG source reconstruction in sparse electromagnetic source imaging. Ding L; Yuan H Hum Brain Mapp; 2013 Apr; 34(4):775-95. PubMed ID: 22102512 [TBL] [Abstract][Full Text] [Related]
36. Harmony: EEG/MEG linear inverse source reconstruction in the anatomical basis of spherical harmonics. Petrov Y PLoS One; 2012; 7(10):e44439. PubMed ID: 23071497 [TBL] [Abstract][Full Text] [Related]
37. Dynamic causal modeling of evoked responses in EEG and MEG. David O; Kiebel SJ; Harrison LM; Mattout J; Kilner JM; Friston KJ Neuroimage; 2006 May; 30(4):1255-72. PubMed ID: 16473023 [TBL] [Abstract][Full Text] [Related]
38. Mapping of the neuronal networks of human cortical brain functions. Momjian S; Seghier M; Seeck M; Michel CM Adv Tech Stand Neurosurg; 2003; 28():91-142. PubMed ID: 12627809 [TBL] [Abstract][Full Text] [Related]
39. Anatomical constraints on source models for high-resolution EEG and MEG derived from MRI. Srinivasan R Technol Cancer Res Treat; 2006 Aug; 5(4):389-99. PubMed ID: 16866569 [TBL] [Abstract][Full Text] [Related]