BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 23128412)

  • 1. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams.
    Wang LL; Perles LA; Archambault L; Sahoo N; Mirkovic D; Beddar S
    Phys Med Biol; 2012 Dec; 57(23):7767-81. PubMed ID: 23128412
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A real-time method to simultaneously measure linear energy transfer and dose for proton therapy using organic scintillators.
    Alsanea F; Therriault-Proulx F; Sawakuchi G; Beddar S
    Med Phys; 2018 Apr; 45(4):1782-1789. PubMed ID: 29446078
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quenching correction for volumetric scintillation dosimetry of proton beams.
    Robertson D; Mirkovic D; Sahoo N; Beddar S
    Phys Med Biol; 2013 Jan; 58(2):261-73. PubMed ID: 23257200
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.
    Wootton L; Holmes C; Sahoo N; Beddar S
    Phys Med Biol; 2015 Feb; 60(3):1185-98. PubMed ID: 25591037
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fluence correction factors in plastic phantoms for clinical proton beams.
    Palmans H; Symons JE; Denis JM; de Kock EA; Jones DT; Vynckier S
    Phys Med Biol; 2002 Sep; 47(17):3055-71. PubMed ID: 12361210
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams.
    Alsanea F; Darne C; Robertson D; Beddar S
    Phys Med Biol; 2020 Apr; 65(7):075005. PubMed ID: 32079001
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
    Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
    Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.
    Wang LL; Klein D; Beddar AS
    Med Phys; 2010 Oct; 37(10):5279-86. PubMed ID: 21089762
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy.
    Alsanea F; Wootton L; Sahoo N; Kudchadker R; Mahmood U; Beddar S
    Phys Med; 2018 Mar; 47():58-63. PubMed ID: 29609819
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.
    Almurayshid M; Helo Y; Kacperek A; Griffiths J; Hebden J; Gibson A
    J Appl Clin Med Phys; 2017 Sep; 18(5):210-219. PubMed ID: 28755419
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A mathematical expression for depth-light curves of therapeutic proton beams in a quenching scintillator.
    Kelleter L; Jolly S
    Med Phys; 2020 Jun; 47(5):2300-2308. PubMed ID: 32072646
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
    Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
    Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.
    Resch AF; Heyes PD; Fuchs H; Bassler N; Georg D; Palmans H
    Med Phys; 2020 Jun; 47(5):2289-2299. PubMed ID: 32166764
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proton dosimetry in a magnetic field: Measurement and calculation of magnetic field correction factors for a plane-parallel ionization chamber.
    Gebauer B; Baumann KS; Fuchs H; Georg D; Oborn BM; Looe HK; Lühr A
    Med Phys; 2024 Mar; 51(3):2293-2305. PubMed ID: 37898105
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Energy dependence of a scintillating fiber detector for preclinical dosimetry with an image guided micro-irradiator.
    Le Deroff C; Frelin AM; Ledoux X
    Phys Med Biol; 2019 May; 64(11):115015. PubMed ID: 30974415
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of surface dose in pencil beam scanning proton therapy.
    Kern A; Bäumer C; Kröninger K; Mertens L; Timmermann B; Walbersloh J; Wulff J
    Med Phys; 2020 Jun; 47(5):2277-2288. PubMed ID: 32037577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Using a small-core graphite calorimeter for dosimetry and scintillator quenching corrections in a therapeutic proton beam.
    Christensen JB; Vestergaard A; Andersen CE
    Phys Med Biol; 2020 Nov; 65(21):215023. PubMed ID: 32526719
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.