These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 23130796)

  • 1. A protection system for the JET ITER-like wall based on imaging diagnostics.
    Arnoux G; Devaux S; Alves D; Balboa I; Balorin C; Balshaw N; Beldishevski M; Carvalho P; Clever M; Cramp S; de Pablos JL; de la Cal E; Falie D; Garcia-Sanchez P; Felton R; Gervaise V; Goodyear A; Horton A; Jachmich S; Huber A; Jouve M; Kinna D; Kruezi U; Manzanares A; Martin V; McCullen P; Moncada V; Obrejan K; Patel K; Lomas PJ; Neto A; Rimini F; Ruset C; Schweer B; Sergienko G; Sieglin B; Soleto A; Stamp M; Stephen A; Thomas PD; Valcárcel DF; Williams J; Wilson J; Zastrow KD;
    Rev Sci Instrum; 2012 Oct; 83(10):10D727. PubMed ID: 23130796
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a mirror-based endoscope for divertor spectroscopy on JET with the new ITER-like wall (invited).
    Huber A; Brezinsek S; Mertens P; Schweer B; Sergienko G; Terra A; Arnoux G; Balshaw N; Clever M; Edlingdon T; Egner S; Farthing J; Hartl M; Horton L; Kampf D; Klammer J; Lambertz HT; Matthews GF; Morlock C; Murari A; Reindl M; Riccardo V; Samm U; Sanders S; Stamp M; Williams J; Zastrow KD; Zauner C;
    Rev Sci Instrum; 2012 Oct; 83(10):10D511. PubMed ID: 23130790
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Upgrade of the infrared camera diagnostics for the JET ITER-like wall divertor.
    Balboa I; Arnoux G; Eich T; Sieglin B; Devaux S; Zeidner W; Morlock C; Kruezi U; Sergienko G; Kinna D; Thomas PD; Rack M;
    Rev Sci Instrum; 2012 Oct; 83(10):10D530. PubMed ID: 23130793
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall.
    Huber V; Huber A; Kinna D; Balboa I; Collins S; Conway N; Drewelow P; Maggi CF; Matthews GF; Meigs AG; Mertens P; Price M; Sergienko G; Silburn S; Wynn A; Zastrow KD
    Rev Sci Instrum; 2016 Nov; 87(11):11D430. PubMed ID: 27910322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An arc control and protection system for the JET lower hybrid antenna based on an imaging system.
    Figueiredo J; Mailloux J; Kirov K; Kinna D; Stamp M; Devaux S; Arnoux G; Edwards JS; Stephen AV; McCullen P; Hogben C;
    Rev Sci Instrum; 2014 Nov; 85(11):11E806. PubMed ID: 25430371
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 2D surface temperature measurement of plasma facing components with modulated active pyrometry.
    Amiel S; Loarer T; Pocheau C; Roche H; Gauthier E; Aumeunier MH; Le Niliot C; Rigollet F; Courtois X; Jouve M; Balorin C; Moncada V
    Rev Sci Instrum; 2014 Oct; 85(10):104905. PubMed ID: 25362442
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New field programmable gate array-based image-oriented acquisition and real-time processing applied to plasma facing component thermal monitoring.
    Martin V; Dunand G; Moncada V; Jouve M; Travere JM
    Rev Sci Instrum; 2010 Oct; 81(10):10E113. PubMed ID: 21033978
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new visible spectroscopy diagnostic for the JET ITER-like wall main chamber.
    Maggi CF; Brezinsek S; Stamp MF; Griph S; Heesterman P; Hogben C; Horton A; Meigs A; Morlock C; Studholme W; Zastrow KD;
    Rev Sci Instrum; 2012 Oct; 83(10):10D517. PubMed ID: 23130791
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnostic options for radiative divertor feedback control on NSTX-U.
    Soukhanovskii VA; Gerhardt SP; Kaita R; McLean AG; Raman R
    Rev Sci Instrum; 2012 Oct; 83(10):10D716. PubMed ID: 23126890
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dust measurements in tokamaks (invited).
    Rudakov DL; Yu JH; Boedo JA; Hollmann EM; Krasheninnikov SI; Moyer RA; Muller SH; Pigarov AY; Rosenberg M; Smirnov RD; West WP; Boivin RL; Bray BD; Brooks NH; Hyatt AW; Wong CP; Roquemore AL; Skinner CH; Solomon WM; Ratynskaia S; Fenstermacher ME; Groth M; Lasnier CJ; McLean AG; Stangeby PC
    Rev Sci Instrum; 2008 Oct; 79(10):10F303. PubMed ID: 19044616
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling of the ITER-like wide-angle infrared thermography view of JET.
    Aumeunier MH; Firdaouss M; Travère JM; Loarer T; Gauthier E; Martin V; Chabaud D; Humbert E;
    Rev Sci Instrum; 2012 Oct; 83(10):10D522. PubMed ID: 23130792
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dust Monitors in JET with ITER-like Wall for Diagnosis of Mobilized Particles and Co-Deposited Layers.
    Fazinić S; Provatas G; Božičević Mihalić I; Tadić T; Rubel M; Grzonka J; Petersson P; Widdowson A; Moon S; Fortuna-Zaleśna E
    Materials (Basel); 2022 Nov; 15(23):. PubMed ID: 36499848
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a realistic photonic modeling for the evaluation of infrared reflections in the metallic environment of ITER.
    Aumeunier MH; Travere JM
    Rev Sci Instrum; 2010 Oct; 81(10):10E524. PubMed ID: 21034052
    [TBL] [Abstract][Full Text] [Related]  

  • 14. X-ray crystal spectrometer upgrade for ITER-like wall experiments at JET.
    Shumack AE; Rzadkiewicz J; Chernyshova M; Jakubowska K; Scholz M; Byszuk A; Cieszewski R; Czarski T; Dominik W; Karpinski L; Kasprowicz G; Pozniak K; Wojenski A; Zabolotny W; Conway NJ; Dalley S; Figueiredo J; Nakano T; Tyrrell S; Zastrow KD; Zoita V;
    Rev Sci Instrum; 2014 Nov; 85(11):11E425. PubMed ID: 25430332
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Recrystallization and grain growth induced by ELMs-like transient heat loads in deformed tungsten samples.
    Suslova A; El-Atwani O; Sagapuram D; Harilal SS; Hassanein A
    Sci Rep; 2014 Nov; 4():6845. PubMed ID: 25366885
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integration of fiber Bragg grating temperature sensors in plasma facing components of the WEST tokamak.
    Corre Y; Laffont G; Pocheau C; Cotillard R; Gaspar J; Roussel N; Firdaouss M; Gardarein JL; Guilhem D; Missirlian M
    Rev Sci Instrum; 2018 Jun; 89(6):063508. PubMed ID: 29960581
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implementation of an in-vessel calibration light source for JET.
    Biewer TM; Belcher C; Hassall I; Hillis DL; Kaveney G; Scharpf D; Stamp MF; Stunell C; Zastrow KD;
    Rev Sci Instrum; 2012 Oct; 83(10):10D505. PubMed ID: 23130789
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Infrared imaging systems for wall protection in the W7-X stellarator (invited).
    Jakubowski M; Drewelow P; Fellinger J; Puig Sitjes A; Wurden G; Ali A; Biedermann C; Cannas B; Chauvin D; Gamradt M; Greve H; Gao Y; Hathiramani D; König R; Lorenz A; Moncada V; Niemann H; Ngo TT; Pisano F; Sunn Pedersen T;
    Rev Sci Instrum; 2018 Oct; 89(10):10E116. PubMed ID: 30399980
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Upgrade of Langmuir probe diagnostic in ITER-like tungsten mono-block divertor on experimental advanced superconducting tokamak.
    Xu JC; Wang L; Xu GS; Luo GN; Yao DM; Li Q; Cao L; Chen L; Zhang W; Liu SC; Wang HQ; Jia MN; Feng W; Deng GZ; Hu LQ; Wan BN; Li J; Sun YW; Guo HY
    Rev Sci Instrum; 2016 Aug; 87(8):083504. PubMed ID: 27587120
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.