These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 23130804)

  • 1. Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamak.
    Mlynar J; Imrisek M; Weinzettl V; Odstrcil M; Havlicek J; Janky F; Alper B; Murari A;
    Rev Sci Instrum; 2012 Oct; 83(10):10E531. PubMed ID: 23130804
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods.
    Imrisek M; Weinzettl V; Mlynar J; Odstrcil T; Odstrcil M; Ficker O; Pinzon JR; Ehrlacher C; Panek R; Hron M
    Rev Sci Instrum; 2014 Nov; 85(11):11E433. PubMed ID: 25430340
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Soft x-ray array system with variable filters for the DIII-D tokamak.
    Hollmann EM; Chousal L; Fisher RK; Hernandez R; Jackson GL; Lanctot MJ; Pidcoe SV; Shankara J; Taussig DA
    Rev Sci Instrum; 2011 Nov; 82(11):113507. PubMed ID: 22128975
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of radial location of rotating magnetic islands by use of poloidal soft x-ray detector arrays in the STOR-M tokamak.
    Dreval M; Xiao C; Elgriw S; Trembach D; Wolfe S; Hirose A
    Rev Sci Instrum; 2011 May; 82(5):053503. PubMed ID: 21639500
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimized tomography methods for plasma emissivity reconstruction at the ASDEX Upgrade tokamak.
    Odstrčil T; Pütterich T; Odstrčil M; Gude A; Igochine V; Stroth U;
    Rev Sci Instrum; 2016 Dec; 87(12):123505. PubMed ID: 28040918
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Phillips-Tikhonov regularization with a priori information for neutron emission tomographic reconstruction on Joint European Torus.
    Bielecki J; Giacomelli L; Kiptily V; Scholz M; Drozdowicz K; Conroy S; Craciunescu T; Kempenaars M;
    Rev Sci Instrum; 2015 Sep; 86(9):093505. PubMed ID: 26429441
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak.
    Li J; Ding Y; Zhang X; Xiao Z; Zhuang G
    Rev Sci Instrum; 2014 Nov; 85(11):11E414. PubMed ID: 25430321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak.
    Bohm P; Sestak D; Bilkova P; Aftanas M; Weinzettl V; Hron M; Panek R; Baillon L; Dunstan MR; Naylor G; Walsh MJ
    Rev Sci Instrum; 2010 Oct; 81(10):10D511. PubMed ID: 21033866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simulation of a tangential soft x-ray imaging system.
    Battaglia DJ; Shafer MW; Unterberg EA; Bell RE; Hillis DL; LeBlanc BP; Maingi R; Sabbagh S; Stratton BC
    Rev Sci Instrum; 2010 Oct; 81(10):10E533. PubMed ID: 21034060
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compact "diode-based" multi-energy soft x-ray diagnostic for NSTX.
    Tritz K; Clayton DJ; Stutman D; Finkenthal M
    Rev Sci Instrum; 2012 Oct; 83(10):10E109. PubMed ID: 23126931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. RADCAM-A radiation camera system combining foil bolometers, AXUV diodes, and filtered soft x-ray diodes.
    Sheikh UA; Simons L; Duval BP; Février O; Moret D; Allegrucci A; Bernert M; Crisinel F; Tersztyánszky T; Villinger O
    Rev Sci Instrum; 2022 Nov; 93(11):113513. PubMed ID: 36461455
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of AXUV diode detectors at ASDEX Upgrade.
    Bernert M; Eich T; Burckhart A; Fuchs JC; Giannone L; Kallenbach A; McDermott RM; Sieglin B;
    Rev Sci Instrum; 2014 Mar; 85(3):033503. PubMed ID: 24689581
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new double-foil soft x-ray array to measure T(e) on the MST reversed field pinch.
    McGarry MB; Franz P; Den Hartog DJ; Goetz JA
    Rev Sci Instrum; 2010 Oct; 81(10):10E516. PubMed ID: 21034044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gaussian process tomography for soft x-ray spectroscopy at WEST without equilibrium information.
    Wang T; Mazon D; Svensson J; Li D; Jardin A; Verdoolaege G
    Rev Sci Instrum; 2018 Jun; 89(6):063505. PubMed ID: 29960552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Soft x-ray virtual diagnostics for tokamak simulations.
    Kim JS; Zhao L; Bogatu IN; In Y; Turnbull A; Osborne T; Maraschek M; Comer K
    Rev Sci Instrum; 2009 Nov; 80(11):113503. PubMed ID: 19947727
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges.
    Zhang J; Zhuang G; Wang ZJ; Ding YH; Zhang XQ; Tang YJ
    Rev Sci Instrum; 2010 Jul; 81(7):073509. PubMed ID: 20687724
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: the high energy x-ray source and some applications.
    Hubert S; Dubois JL; Gontier D; Lidove G; Reverdin C; Soullié G; Stemmler P; Villette B
    Rev Sci Instrum; 2010 May; 81(5):053501. PubMed ID: 20515133
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plasma radiation dynamics with the upgraded Absolute Extreme Ultraviolet tomographical system in the Tokamak à Configuration Variable.
    Tal B; Labit B; Nagy D; Chavan R; Duval B; Veres G
    Rev Sci Instrum; 2013 Dec; 84(12):123508. PubMed ID: 24387434
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Edge multi-energy soft x-ray diagnostic in Experimental Advanced Superconducting Tokamak.
    Li YL; Xu GS; Tritz K; Zhu YB; Wan BN; Lan H; Liu YL; Wei J; Zhang W; Hu GH; Wang HQ; Duan YM; Zhao JL; Wang L; Liu SC; Ye Y; Li J; Lin X; Li XL
    Rev Sci Instrum; 2015 Dec; 86(12):123512. PubMed ID: 26724032
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-time plasma control based on the ISTTOK tomography diagnostic.
    Carvalho PJ; Carvalho BB; Neto A; Coelho R; Fernandes H; Sousa J; Varandas C; Chávez-Alarcón E; Herrera-Velázquez JJ
    Rev Sci Instrum; 2008 Oct; 79(10):10F329. PubMed ID: 19044637
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.