  • 21. Replacement of continuous-flow left ventricular assist device via left subcostal incision.
    Rogers JG; Jollis JG; Milano CA
    J Thorac Cardiovasc Surg; 2012 Apr; 143(4):975-6. PubMed ID: 22035962
    [No Abstract]   [Full Text] [Related]  

  • 22. Driveline insulation as a conduit for left ventricular assist device pocket infection.
    Pinninti M; Thohan V; Sulemanjee NZ
    J Thorac Cardiovasc Surg; 2014 Jul; 148(1):e135-6. PubMed ID: 24755334
    [No Abstract]   [Full Text] [Related]  

  • 23. Left ventricle assist device: when and which patients should we refer?
    Trochu JN; Leprince P; Bielefeld-Gomez M; Bastien O; Beauvais F; Gueffet JP; Logeart D; Isnard R; Iliou MC; Leclercq C; Girard C
    Arch Cardiovasc Dis; 2012 Feb; 105(2):114-21. PubMed ID: 22424329
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Continuous-flow rotary left ventricular assist devices with "3rd generation" design.
    Pagani FD
    Semin Thorac Cardiovasc Surg; 2008; 20(3):255-63. PubMed ID: 19038736
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Successful use of the HeartWare HVAD rotary blood pump for biventricular support.
    Strueber M; Meyer AL; Malehsa D; Haverich A
    J Thorac Cardiovasc Surg; 2010 Oct; 140(4):936-7. PubMed ID: 20478575
    [No Abstract]   [Full Text] [Related]  

  • 26. Cardiac transplant or rotary blood pump: contemporary evidence.
    Westaby S
    J Thorac Cardiovasc Surg; 2013 Jan; 145(1):24-31. PubMed ID: 23244251
    [No Abstract]   [Full Text] [Related]  

  • 27. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
    Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S
    Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Occult gastrointestinal bleeding in patients with a left ventricular assist device axial flow pump: diagnostic tools and therapeutic algorithm.
    Tarzia V; Dal Lin C; Bottio T; Benvenuti S; Chilovi F; Gerosa G
    J Thorac Cardiovasc Surg; 2012 Apr; 143(4):e28-31. PubMed ID: 22306228
    [No Abstract]   [Full Text] [Related]  

  • 29. Echocardiographic Features of the Fully Magnetically Levitated LVAD.
    Magunia H; Schibilsky D; Hilberath JN; Schlensak C; Rosenberger P; Nowak-Machen M
    JACC Cardiovasc Imaging; 2017 Jul; 10(7):819-822. PubMed ID: 27568116
    [No Abstract]   [Full Text] [Related]  

  • 30. Afterload Sensitivity of Continuous-Flow Left Ventricular Assist Devices and Abolition of Frank-Starling Forces Under Strain.
    Jain P; Hayward CS
    Circ Heart Fail; 2020 Feb; 13(2):e006787. PubMed ID: 32059631
    [No Abstract]   [Full Text] [Related]  

  • 31. Utilization of the Impella 2.5 micro-axial pump in children for acute circulatory support.
    Dimas VV; Murthy R; Guleserian KJ
    Catheter Cardiovasc Interv; 2014 Feb; 83(2):261-2. PubMed ID: 23729308
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Lung lobectomy in a patient with an implantable left ventricular assist device.
    Murakawa T; Murayama T; Nakajima J; Ono M
    Interact Cardiovasc Thorac Surg; 2011 Dec; 13(6):676-8. PubMed ID: 21891798
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of polytetrafluoroethylene vascular graft to cover the kinking protector of left ventricular assist device facilitates later pump exchange.
    Potapov EV; Hetzer R; Krabatsch T
    J Thorac Cardiovasc Surg; 2014 Aug; 148(2):745-6. PubMed ID: 24768102
    [No Abstract]   [Full Text] [Related]  

  • 34. Pulsatile left ventricular assist devices: what is the role in the modern era?
    Atluri P; Acker MA
    Semin Thorac Cardiovasc Surg; 2010; 22(2):106-8. PubMed ID: 21092883
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessment of long-term anticoagulation in patients with a continuous-flow left-ventricular assist device: a pilot study.
    Jennings D; McDonnell J; Schillig J
    J Thorac Cardiovasc Surg; 2011 Jul; 142(1):e1-2. PubMed ID: 21529846
    [No Abstract]   [Full Text] [Related]  

  • 36. MY APPROACH to left ventricular assist device therapy.
    Mehra MR
    Trends Cardiovasc Med; 2015 Oct; 25(7):657-8. PubMed ID: 26398273
    [No Abstract]   [Full Text] [Related]  

  • 37. Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.
    Haft J; Armstrong W; Dyke DB; Aaronson KD; Koelling TM; Farrar DJ; Pagani FD
    Circulation; 2007 Sep; 116(11 Suppl):I8-15. PubMed ID: 17846330
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.
    John R; Kamdar F; Liao K; Colvin-Adams M; Miller L; Joyce L; Boyle A
    J Thorac Cardiovasc Surg; 2008 Nov; 136(5):1318-23. PubMed ID: 19026822
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Autosynchronized systolic unloading during left ventricular assist with a centrifugal pump.
    Kono S; Nishimura K; Nishina T; Yuasa S; Ueyama K; Hamada C; Akamatsu T; Komeda M
    J Thorac Cardiovasc Surg; 2003 Feb; 125(2):353-60. PubMed ID: 12579105
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data.
    Morley D; Litwak K; Ferber P; Spence P; Dowling R; Meyns B; Griffith B; Burkhoff D
    J Thorac Cardiovasc Surg; 2007 Jan; 133(1):21-8. PubMed ID: 17198776
    [TBL] [Abstract][Full Text] [Related]  