These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 23141732)

  • 1. [Corrosion resistance of casted titanium by compound treatments in the artificial saliva with different fluoride concentrations].
    Wang XL; Guo TW
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2012 Sep; 47(9):557-61. PubMed ID: 23141732
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of plasma nitriding and titanium nitride coating on the corrosion resistance of titanium.
    Wang X; Bai S; Li F; Li D; Zhang J; Tian M; Zhang Q; Tong Y; Zhang Z; Wang G; Guo T; Ma C
    J Prosthet Dent; 2016 Sep; 116(3):450-6. PubMed ID: 27061632
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effect of pH value and fluoride ions on corrosion resistance of pure Ti and Ni-Cr-Ti alloy in artificial saliva].
    Liang BG; Shen XT; Liu L; Lü YX; Yu ZD; Yang CX; Zhang YZ
    Zhejiang Da Xue Xue Bao Yi Xue Ban; 2010 Jul; 39(4):399-403. PubMed ID: 20731040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Stress and electrochemical corrosion of titanium produced by laser rapid forming].
    Zhu JF; Gan K; Du TF; Gao B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Apr; 54(4):257-262. PubMed ID: 30955298
    [No Abstract]   [Full Text] [Related]  

  • 5. Corrosion resistance of different nickel-titanium archwires in acidic fluoride-containing artificial saliva.
    Lee TH; Huang TK; Lin SY; Chen LK; Chou MY; Huang HH
    Angle Orthod; 2010 May; 80(3):547-53. PubMed ID: 20050751
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The effect of fluoride on electrochemical corrosion of the dental pure titanium before and after adhesion of Streptococcus mutans].
    Geng L; Qiao GY; Gu KK
    Shanghai Kou Qiang Yi Xue; 2016 Apr; 25(2):150-6. PubMed ID: 27329875
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Influence of TiN, TiCN coating on corrosion resistance of dental pure titanium].
    DU JJ; Yu WQ; Wang DL
    Shanghai Kou Qiang Yi Xue; 2011 Aug; 20(4):385-9. PubMed ID: 21909603
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion resistance of three orthodontic brackets: a comparative study of three fluoride mouthwashes.
    Schiff N; Dalard F; Lissac M; Morgon L; Grosgogeat B
    Eur J Orthod; 2005 Dec; 27(6):541-9. PubMed ID: 16049037
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How do titanium and Ti6Al4V corrode in fluoridated medium as found in the oral cavity? An in vitro study.
    Souza JC; Barbosa SL; Ariza EA; Henriques M; Teughels W; Ponthiaux P; Celis JP; Rocha LA
    Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():384-93. PubMed ID: 25492211
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corrosion resistance of NiTi in fluoride and acid environments.
    Benyahia H; Ebntouhami M; Forsal I; Zaoui F; Aalloula E
    Int Orthod; 2009 Dec; 7(4):322-34. PubMed ID: 20303919
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Experimental study on the corrosion behavior of a type of oral near β-type titanium alloys modified with double glow plasma nitriding].
    Wen K; Li F
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2015 Dec; 50(12):751-4. PubMed ID: 26887401
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface corrosion and fracture resistance of two nickel-titanium-based archwires induced by fluoride, pH, and thermocycling. An in vitro comparative study.
    Perinetti G; Contardo L; Ceschi M; Antoniolli F; Franchi L; Baccetti T; Di Lenarda R
    Eur J Orthod; 2012 Feb; 34(1):1-9. PubMed ID: 21041836
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corrosion behaviour of TiN and ZrN in the environment containing fluoride ions.
    Joska L; Fojt J; Hradilova M; Hnilica F; Cvrcek L
    Biomed Mater; 2010 Oct; 5(5):054108. PubMed ID: 20876958
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of a two-year fluoride decay protection protocol on titanium brackets.
    Khoury ES; Abboud M; Bassil-Nassif N; Bouserhal J
    Int Orthod; 2011 Dec; 9(4):432-51. PubMed ID: 22032966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of fluoride ions on the corrosion behaviour of Ti metal, and Ti6-Al-7Nb and Ti-6Al-4V alloys in artificial saliva.
    Milošev I; Kapun B; Selih VS
    Acta Chim Slov; 2013; 60(3):543-55. PubMed ID: 24169708
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of Ag on the corrosion behavior of Ti-Ag alloys in artificial saliva solutions.
    Zhang BB; Zheng YF; Liu Y
    Dent Mater; 2009 May; 25(5):672-7. PubMed ID: 19150734
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of friction force between corroded and noncorroded titanium nitride plating of metal brackets.
    Kao CT; Guo JU; Huang TH
    Am J Orthod Dentofacial Orthop; 2011 May; 139(5):594-600. PubMed ID: 21536201
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium.
    Mabilleau G; Bourdon S; Joly-Guillou ML; Filmon R; Baslé MF; Chappard D
    Acta Biomater; 2006 Jan; 2(1):121-9. PubMed ID: 16701867
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface treatment influences electrochemical stability of cpTi exposed to mouthwashes.
    Beline T; Garcia CS; Ogawa ES; Marques ISV; Matos AO; Sukotjo C; Mathew MT; Mesquita MF; Consani RX; Barão VAR
    Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():1079-1088. PubMed ID: 26652467
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.