BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 23143570)

  • 1. An open system for intravascular ultrasound imaging.
    Qiu W; Chen Y; Li X; Yu Y; Cheng WF; Tsang FK; Zhou Q; Shung KK; Dai J; Sun L
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Oct; 59(10):2201-9. PubMed ID: 23143570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel dual-frequency imaging method for intravascular ultrasound applications.
    Qiu W; Chen Y; Wong CM; Liu B; Dai J; Zheng H
    Ultrasonics; 2015 Mar; 57():31-5. PubMed ID: 25454093
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modulated Excitation Imaging System for Intravascular Ultrasound.
    Qiu W; Wang X; Chen Y; Fu Q; Su M; Zhang L; Xia J; Dai J; Zhang Y; Zheng H
    IEEE Trans Biomed Eng; 2017 Aug; 64(8):1935-1942. PubMed ID: 27893376
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dual-Element Intravascular Ultrasound Transducer for Tissue Harmonic Imaging and Frequency Compounding: Development and Imaging Performance Assessment.
    Lee J; Chang JH
    IEEE Trans Biomed Eng; 2019 Nov; 66(11):3146-3155. PubMed ID: 30835204
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multi-frequency intravascular ultrasound (IVUS) imaging.
    Ma T; Yu M; Li J; Munding CE; Chen Z; Fei C; Shung KK; Zhou Q
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Jan; 62(1):97-107. PubMed ID: 25585394
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.
    Li X; Ma T; Tian J; Han P; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jul; 61(7):1171-8. PubMed ID: 24960706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Single-Crystal High-Frequency Intravascular Ultrasound Transducer With 40- μ m Axial Resolution.
    Ma X; Cao W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Apr; 67(4):810-816. PubMed ID: 31794395
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 30/80 MHz Bidirectional Dual-Frequency IVUS Feasibility Evaluated In Vivo and for Stent Imaging.
    Munding CE; Chérin E; Alves N; Goertz DE; Courtney BK; Foster FS
    Ultrasound Med Biol; 2020 Aug; 46(8):2104-2112. PubMed ID: 32473846
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrawide-bandwidth high-resolution all-optical intravascular ultrasound using miniaturized photoacoustic transducer.
    Wang L; Zhao Y; Zheng B; Huo Y; Fan Y; Ma D; Gu Y; Wang P
    Sci Adv; 2023 Jun; 9(23):eadg8600. PubMed ID: 37294755
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Visualization of plaque distribution in a curved artery: three-dimensional intravascular ultrasound imaging.
    Choi A; McPherson DD; Kim H
    Comput Assist Surg (Abingdon); 2017 Dec; 22(sup1):120-126. PubMed ID: 29034729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Oblong-Shaped-Focused Transducers for Intravascular Ultrasound Imaging.
    Lee J; Jang J; Chang JH
    IEEE Trans Biomed Eng; 2017 Mar; 64(3):671-680. PubMed ID: 27244714
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Harmonic intravascular ultrasound imaging with a dual-frequency catheter.
    Frijlink ME; Goertz DE; Vos HJ; Tesselaar E; Blacquière G; Gisolf A; Krams R; van der Steen AF
    Ultrasound Med Biol; 2006 Nov; 32(11):1649-54. PubMed ID: 17112951
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nonlinear intravascular ultrasound contrast imaging.
    Goertz DE; Frijlink ME; de Jong N; van der Steen AF
    Ultrasound Med Biol; 2006 Apr; 32(4):491-502. PubMed ID: 16616596
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Backing-Layer-Shared Miniature Dual-Frequency Ultrasound Probe for Intravascular Ultrasound Imaging: In Vitro and Ex Vivo Validations.
    He Y; Liu X; Zhang J; Peng C
    Biosensors (Basel); 2023 Nov; 13(11):. PubMed ID: 37998146
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.
    Peng C; Wu H; Kim S; Dai X; Jiang X
    Sensors (Basel); 2021 May; 21(10):. PubMed ID: 34069613
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lead-free intravascular ultrasound transducer using BZT-50BCT ceramics.
    Yan X; Lam KH; Li X; Chen R; Ren W; Ren X; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jun; 60(6):1272-6. PubMed ID: 25004492
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of a 3 French Dual-Frequency Intravascular Ultrasound Catheter.
    Munding CE; Chérin E; Jourard I; Weyers JJ; Goertz DE; Courtney BK; Foster FS
    Ultrasound Med Biol; 2018 Jan; 44(1):251-266. PubMed ID: 29150363
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design, construction, and validation of a rotary multifunctional intravascular diagnostic catheter combining multispectral fluorescence lifetime imaging and intravascular ultrasound.
    Bec J; Xie H; Yankelevich DR; Zhou F; Sun Y; Ghata N; Aldredge R; Marcu L
    J Biomed Opt; 2012 Oct; 17(10):106012. PubMed ID: 23224011
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review.
    Sung JH; Chang JH
    Sensors (Basel); 2021 Jun; 21(11):. PubMed ID: 34198822
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multimodality imaging of attenuated plaque using grayscale and virtual histology intravascular ultrasound and optical coherent tomography.
    Kang SJ; Ahn JM; Han S; Park DW; Lee SW; Kim YH; Lee CW; Park SW; Mintz GS; Park SJ
    Catheter Cardiovasc Interv; 2016 Jul; 88(1):E1-E11. PubMed ID: 25511369
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.