These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

420 related articles for article (PubMed ID: 23146480)

  • 21. Relation between echocardiographically estimated and invasively measured filling pressures in constrictive pericarditis.
    Alraies MC; Kusunose K; Negishi K; Yarmohammadi H; Motoki H; AlJaroudi W; Popović ZB; Klein AL
    Am J Cardiol; 2014 Jun; 113(11):1911-6. PubMed ID: 24837273
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Doppler tissue imaging for assessing left ventricular diastolic dysfunction in heart transplant rejection.
    Stengel SM; Allemann Y; Zimmerli M; Lipp E; Kucher N; Mohacsi P; Seiler C
    Heart; 2001 Oct; 86(4):432-7. PubMed ID: 11559685
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Can transthoracic Doppler echocardiography predict the discrepancy between left ventricular end-diastolic pressure and mean pulmonary capillary wedge pressure in patients with heart failure?
    Hadano Y; Murata K; Liu J; Oyama R; Harada N; Okuda S; Hamada Y; Tanaka N; Matsuzaki M
    Circ J; 2005 Apr; 69(4):432-8. PubMed ID: 15791038
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Abnormal septal motion affects early diastolic velocities at the septal and lateral mitral annulus, and impacts on estimation of the pulmonary capillary wedge pressure.
    D'Souza KA; Mooney DJ; Russell AE; MacIsaac AI; Aylward PE; Prior DL
    J Am Soc Echocardiogr; 2005 May; 18(5):445-53. PubMed ID: 15891754
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Haemodynamic response during low-dose dobutamine infusion in patients with chronic systolic heart failure: comparison of echocardiographic and invasive measurements.
    Egstrup M; Gustafsson I; Andersen MJ; Kistorp CN; Schou M; Tuxen CD; Møller JE
    Eur Heart J Cardiovasc Imaging; 2013 Jul; 14(7):659-67. PubMed ID: 23136446
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Echocardiographic evaluation of left ventricular filling pressure in heart transplant recipients.
    Broch K; Al-Ani A; Gude E; Gullestad L; Aakhus S
    Scand Cardiovasc J; 2014 Dec; 48(6):349-56. PubMed ID: 25414078
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An index of early left ventricular filling that combined with pulsed Doppler peak E velocity may estimate capillary wedge pressure.
    Garcia MJ; Ares MA; Asher C; Rodriguez L; Vandervoort P; Thomas JD
    J Am Coll Cardiol; 1997 Feb; 29(2):448-54. PubMed ID: 9015003
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Doppler analysis of pulmonary venous flow profiles in orthotopic heart transplant recipients: a comparison with mitral flow profiles and atrial function.
    Spes CH; Tammen AR; Fraser AG; Uberfuhr P; Theisen K; Angermann CE
    Z Kardiol; 1996 Oct; 85(10):753-60. PubMed ID: 8943501
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Doppler estimation of left ventricular filling pressures in patients with mitral valve disease.
    Diwan A; McCulloch M; Lawrie GM; Reardon MJ; Nagueh SF
    Circulation; 2005 Jun; 111(24):3281-9. PubMed ID: 15956127
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Echocardiography detects elevated left ventricular filling pressures in heart transplant recipients.
    Bech-Hanssen O; Al-Habeeb W; Ahmed W; Di Salvo G; Pergola V; Al-Admawi M; Al-Amri M; Al-Shahid M; Al-Buraiki J; Fadel BM
    Echocardiography; 2015 Mar; 32(3):411-9. PubMed ID: 24995376
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Echocardiographic indices do not reliably track changes in left-sided filling pressure in healthy subjects or patients with heart failure with preserved ejection fraction.
    Bhella PS; Pacini EL; Prasad A; Hastings JL; Adams-Huet B; Thomas JD; Grayburn PA; Levine BD
    Circ Cardiovasc Imaging; 2011 Sep; 4(5):482-9. PubMed ID: 21788358
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Tissue Doppler velocities for ruling out rejection in heart transplant recipients in the context of myocardial strain imaging: a multivariate, prospective, single-center study.
    Ruiz Ortiz M; Rodríguez Diego S; Delgado Ortega M; Sánchez Fernández JJ; Ortega Salas R; Carnero Montoro L; Carrasco Ávalos F; López Aguilera J; López Granados A; Arizón Del Prado JM; Romo Peñas E; Paredes Hurtado N; Oneto Fernández J; Pan M; Mesa Rubio D
    Int J Cardiovasc Imaging; 2020 Aug; 36(8):1455-1464. PubMed ID: 32297099
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Doppler evaluations of left ventricular diastolic filling and pulmonary wedge pressure provide similar prognostic information in patients with systolic dysfunction after myocardial infarction.
    Pozzoli M; Capomolla S; Sanarico M; Pinna G; Cobelli F; Tavazzi L
    Am Heart J; 1995 Apr; 129(4):716-25. PubMed ID: 7900623
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Tissue Doppler imaging detects severely abnormal myocardial velocities that identify children with pre-terminal cardiac graft failure after heart transplantation.
    Fyfe DA; Ketchum D; Lewis R; Sabatier J; Kanter K; Mahle W; Vincent R
    J Heart Lung Transplant; 2006 May; 25(5):510-7. PubMed ID: 16678028
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Non-invasive tissue Doppler imaging pulmonary capillary wedge pressure measurement improves NT-proBNP prognostic value in heart failure.
    Berni A; Cappelli F; Bitossi L; Cecioni I; Cappelli B; Toncelli L; Galanti G; Poggesi L
    Acta Cardiol; 2009 Apr; 64(2):213-8. PubMed ID: 19476114
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Impact of mitral E/A ratio on the accuracy of different echocardiographic indices to estimate left ventricular end-diastolic pressure.
    Poerner TC; Goebel B; Kralev S; Kaden JJ; Süselbeck T; Haase KK; Borggrefe M; Haghi D
    Ultrasound Med Biol; 2007 May; 33(5):699-707. PubMed ID: 17383798
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of Doppler echocardiography, color M-mode Doppler, and Doppler tissue imaging for the estimation of pulmonary capillary wedge pressure.
    González-Vilchez F; Ayuela J; Ares M; Mata NS; González AG; Durán RM
    J Am Soc Echocardiogr; 2002 Oct; 15(10 Pt 2):1245-50. PubMed ID: 12411912
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optimal noninvasive assessment of left ventricular filling pressures: a comparison of tissue Doppler echocardiography and B-type natriuretic peptide in patients with pulmonary artery catheters.
    Dokainish H; Zoghbi WA; Lakkis NM; Al-Bakshy F; Dhir M; Quinones MA; Nagueh SF
    Circulation; 2004 May; 109(20):2432-9. PubMed ID: 15123522
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Doppler estimation of left ventricular filling pressure in sinus tachycardia. A new application of tissue doppler imaging.
    Nagueh SF; Mikati I; Kopelen HA; Middleton KJ; Quiñones MA; Zoghbi WA
    Circulation; 1998 Oct; 98(16):1644-50. PubMed ID: 9778330
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Serial Doppler echocardiography and tissue Doppler imaging in the detection of elevated directly measured left atrial pressure in ambulant subjects with chronic heart failure.
    Ritzema JL; Richards AM; Crozier IG; Frampton CF; Melton IC; Doughty RN; Stewart JT; Eigler N; Whiting J; Abraham WT; Troughton RW
    JACC Cardiovasc Imaging; 2011 Sep; 4(9):927-34. PubMed ID: 21920328
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.