These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 23146584)

  • 21. Rotating hinge knee causes lower bone-implant interface stress compared to constrained condylar knee replacement.
    Samiezadeh S; Bougherara H; Abolghasemian M; D'Lima D; Backstein D
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1224-1231. PubMed ID: 30039293
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [-Knee prosthesis-].
    Mathieu P; Sautet A
    Ann Radiol (Paris); 1997; 40(1):40-8. PubMed ID: 9754350
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Correction of ligament and bone defects in total arthroplasty of the severely valgus knee.
    Whiteside LA
    Clin Orthop Relat Res; 1993 Mar; (288):234-45. PubMed ID: 8458139
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radiologic case study. Failed total knee arthroplasty with dislocated rotating platform polyethylene component.
    Bancroft LW; Peterson JJ; Blasser KE
    Orthopedics; 2009 Sep; 32(9):626-94. PubMed ID: 19754036
    [No Abstract]   [Full Text] [Related]  

  • 25. Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.
    Friesenbichler J; Maurer-Ertl W; Sadoghi P; Lovse T; Windhager R; Leithner A
    Int Orthop; 2012 Mar; 36(3):539-44. PubMed ID: 21755331
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Total knee arthroplasty with modular rotating-platform hinge.
    Jones RE
    Orthopedics; 2006 Sep; 29(9 Suppl):S80-2. PubMed ID: 17002157
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Uncemented knee prosthesis. Results apropos of 58 cases with a minimum of 5-year follow-up].
    Gacon G; Coillard JY; Barba L; Travers V
    Rev Chir Orthop Reparatrice Appar Mot; 1995; 81(6):505-13. PubMed ID: 8560021
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Posterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.
    Elwood JJ; Callaghan JJ; Liu SS; Goetz DD
    Orthopedics; 2012 Dec; 35(12):e1699-704. PubMed ID: 23218624
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Patient-reported outcomes after primary rotating hinge total knee arthroplasty: a multi-centre clinical cohort study.
    Dauwe J; Vandekerckhove B; Bouttelgier R; Holzer LA; Dauwe D; Vandenneucker H
    Int Orthop; 2021 Nov; 45(11):2893-2897. PubMed ID: 34324043
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Forces at the implant-bone interface of condylar knee prosthesis--with special reference to the retention of the posterior cruciate ligament].
    Kurosawa H; Soudry M; Walker PS
    Nihon Seikeigeka Gakkai Zasshi; 1984 Jan; 58(1):11-21. PubMed ID: 6747399
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Rotating-hinge total knee arthroplasty in a patient with genu recurvatum after osteomyelitis of the distal femur.
    Nishitani K; Nakagawa Y; Suzuki T; Koike K; Nakamura T
    J Arthroplasty; 2007 Jun; 22(4):630-3. PubMed ID: 17562427
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Results of a second-generation constrained condylar prosthesis in primary total knee arthroplasty.
    Lachiewicz PF; Soileau ES
    J Arthroplasty; 2011 Dec; 26(8):1228-31. PubMed ID: 21778031
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Early nontraumatic fracture of the polyethylene tibial post in a NexGen LPS-Flex posterior stabilized knee prosthesis.
    Lee CS; Chen WM; Kou HC; Lo WH; Chen CL
    J Arthroplasty; 2009 Dec; 24(8):1292.e5-9. PubMed ID: 19303252
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Selective ligament release in total knee arthroplasty of the knee in valgus.
    Whiteside LA
    Clin Orthop Relat Res; 1999 Oct; (367):130-40. PubMed ID: 10546607
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Application of the Endomodel rotating hinge knee prosthesis for knee osteoarthritis.
    Mavrodontidis AN; Andrikoula SI; Kontogeorgakos VA; Babis GC; Xenakis TA; Beris AE; Soucacos PN
    J Surg Orthop Adv; 2008; 17(3):179-84. PubMed ID: 18851803
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Rotating Hinge Implants in Knee Arthroplasty.
    Petershofer A; Trieb K
    Z Orthop Unfall; 2020 Aug; 158(4):383-389. PubMed ID: 31404939
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evolution of the rotating hinge for complex total knee arthroplasty.
    Barrack RL
    Clin Orthop Relat Res; 2001 Nov; (392):292-9. PubMed ID: 11716398
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Retrieval Analysis of Polyethylene Components in Rotating Hinge Knee Arthroplasty Implants.
    Kahlenberg CA; Baral EC; Lieberman LW; Huang RC; Wright TM; Padgett DE
    J Arthroplasty; 2021 Aug; 36(8):2998-3003. PubMed ID: 33931282
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Total knee arthroplasty in femorotibial instability.
    Argenson JN; Aubaniac JM
    Orthopade; 2000 Jun; 29 Suppl 1():S45-7. PubMed ID: 10929353
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature.
    Friesenbichler J; Schwarzkopf R; Sadoghi P; Marwin SE; Glehr M; Maurer-Ertl W; Leithner A
    Int Orthop; 2012 May; 36(5):993-8. PubMed ID: 22202962
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.