212 related articles for article (PubMed ID: 23148084)
21. In-hospital outcome of transcatheter vs. surgical aortic valve replacement in patients with aortic valve stenosis: complete dataset of patients treated in 2013 in Germany.
Möllmann H; Bestehorn K; Bestehorn M; Papoutsis K; Fleck E; Ertl G; Kuck KH; Hamm C
Clin Res Cardiol; 2016 Jun; 105(6):553-9. PubMed ID: 26830097
[TBL] [Abstract][Full Text] [Related]
22. Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study.
Kahlert P; Al-Rashid F; Döttger P; Mori K; Plicht B; Wendt D; Bergmann L; Kottenberg E; Schlamann M; Mummel P; Holle D; Thielmann M; Jakob HG; Konorza T; Heusch G; Erbel R; Eggebrecht H
Circulation; 2012 Sep; 126(10):1245-55. PubMed ID: 22899774
[TBL] [Abstract][Full Text] [Related]
23. "Heart Team" decision making in elderly patients with symptomatic aortic valve stenosis who underwent AVR or TAVI - a look behind the curtain. Results of the prospective TAVI Calculation of Costs Trial (TCCT).
Kaier K; Gutmann A; Vach W; Sorg S; Siepe M; von Zur Mühlen C; Moser M; Blanke P; Beyersdorf F; Zehender M; Bode C; Reinöhl J
EuroIntervention; 2015 Nov; 11(7):793-8. PubMed ID: 25499832
[TBL] [Abstract][Full Text] [Related]
24. Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation.
Erdoes G; Basciani R; Huber C; Stortecky S; Wenaweser P; Windecker S; Carrel T; Eberle B
Eur J Cardiothorac Surg; 2012 Apr; 41(4):778-83; discussion 783-4. PubMed ID: 22423058
[TBL] [Abstract][Full Text] [Related]
25. TriGuard
Samim M; van der Worp B; Agostoni P; Hendrikse J; Budde RP; Nijhoff F; Ramjankhan F; Doevendans PA; Stella PR
Catheter Cardiovasc Interv; 2017 Feb; 89(3):470-477. PubMed ID: 27121306
[TBL] [Abstract][Full Text] [Related]
26. Clinical implications for diffusion-weighted MRI brain lesions associated with transcatheter aortic valve replacement.
Meller SM; Baumbach A; Brickman AM; Lansky AJ
Catheter Cardiovasc Interv; 2014 Feb; 83(3):502-8. PubMed ID: 23460315
[TBL] [Abstract][Full Text] [Related]
27. Chronic obstructive pulmonary disease in patients undergoing transcatheter aortic valve implantation: insights on clinical outcomes, prognostic markers, and functional status changes.
Mok M; Nombela-Franco L; Dumont E; Urena M; DeLarochellière R; Doyle D; Villeneuve J; Côté M; Ribeiro HB; Allende R; Laflamme J; DeLarochellière H; Laflamme L; Amat-Santos I; Pibarot P; Maltais F; Rodés-Cabau J
JACC Cardiovasc Interv; 2013 Oct; 6(10):1072-84. PubMed ID: 24156967
[TBL] [Abstract][Full Text] [Related]
28. First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation.
Naber CK; Ghanem A; Abizaid AA; Wolf A; Sinning JM; Werner N; Nickenig G; Schmitz T; Grube E
EuroIntervention; 2012 May; 8(1):43-50. PubMed ID: 22403768
[TBL] [Abstract][Full Text] [Related]
29. Transfemoral versus Transapical Aortic Implantation for Aortic Stenosis Based on No Significant Difference in Logistic EuroSCORE: A Meta-Analysis.
Liu Z; He R; Wu C; Xia Y
Thorac Cardiovasc Surg; 2016 Aug; 64(5):374-81. PubMed ID: 26121378
[TBL] [Abstract][Full Text] [Related]
30. A 3-center comparison of 1-year mortality outcomes between transcatheter aortic valve implantation and surgical aortic valve replacement on the basis of propensity score matching among intermediate-risk surgical patients.
Piazza N; Kalesan B; van Mieghem N; Head S; Wenaweser P; Carrel TP; Bleiziffer S; de Jaegere PP; Gahl B; Anderson RH; Kappetein AP; Lange R; Serruys PW; Windecker S; Jüni P
JACC Cardiovasc Interv; 2013 May; 6(5):443-51. PubMed ID: 23702009
[TBL] [Abstract][Full Text] [Related]
31. Transapical aortic valve implantation in patients with previous cardiac surgery.
Papadopoulos N; Ilioska P; Fichtlscherer S; Lehmann R; Beiras Fernandez A; Moritz A; Doss M; Zierer A
Ann Thorac Surg; 2014 Jan; 97(1):37-42. PubMed ID: 24075497
[TBL] [Abstract][Full Text] [Related]
32. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging.
Ghanem A; Müller A; Nähle CP; Kocurek J; Werner N; Hammerstingl C; Schild HH; Schwab JO; Mellert F; Fimmers R; Nickenig G; Thomas D
J Am Coll Cardiol; 2010 Apr; 55(14):1427-32. PubMed ID: 20188503
[TBL] [Abstract][Full Text] [Related]
33. Cognitive trajectory after transcatheter aortic valve implantation.
Ghanem A; Kocurek J; Sinning JM; Wagner M; Becker BV; Vogel M; Schröder T; Wolfsgruber S; Vasa-Nicotera M; Hammerstingl C; Schwab JO; Thomas D; Werner N; Grube E; Nickenig G; Müller A
Circ Cardiovasc Interv; 2013 Dec; 6(6):615-24. PubMed ID: 24129642
[TBL] [Abstract][Full Text] [Related]
34. The silent and apparent neurological injury in transcatheter aortic valve implantation study (SANITY): concept, design and rationale.
Fanning JP; Wesley AJ; Platts DG; Walters DL; Eeles EM; Seco M; Tronstad O; Strugnell W; Barnett AG; Clarke AJ; Bellapart J; Vallely MP; Tesar PJ; Fraser JF
BMC Cardiovasc Disord; 2014 Apr; 14():45. PubMed ID: 24708720
[TBL] [Abstract][Full Text] [Related]
35. Increased Risk of Cerebral Embolization After Implantation of a Balloon-Expandable Aortic Valve Without Prior Balloon Valvuloplasty.
Bijuklic K; Haselbach T; Witt J; Krause K; Hansen L; Gehrckens R; Rieß FC; Schofer J
JACC Cardiovasc Interv; 2015 Oct; 8(12):1608-13. PubMed ID: 26386760
[TBL] [Abstract][Full Text] [Related]
36. Comparison between Society of Thoracic Surgeons score and logistic EuroSCORE for predicting mortality in patients referred for transcatheter aortic valve implantation.
Ben-Dor I; Gaglia MA; Barbash IM; Maluenda G; Hauville C; Gonzalez MA; Sardi G; Laynez-Carnicero A; Torguson R; Okubagzi P; Xue Z; Goldstein SA; Suddath WO; Kent KM; Lindsay J; Satler LF; Pichard AD; Waksman R
Cardiovasc Revasc Med; 2011; 12(6):345-9. PubMed ID: 21741324
[TBL] [Abstract][Full Text] [Related]
37. Transcranial Doppler sound detection of cerebral microembolism during transapical aortic valve implantation.
Drews T; Pasic M; Buz S; Unbehaun A; Dreysse S; Kukucka M; Mladenow A; Hetzer R
Thorac Cardiovasc Surg; 2011 Jun; 59(4):237-42. PubMed ID: 21442580
[TBL] [Abstract][Full Text] [Related]
38. Treating the patients in the 'grey-zone' with aortic valve disease: a comparison among conventional surgery, sutureless valves and transcatheter aortic valve replacement.
Muneretto C; Bisleri G; Moggi A; Di Bacco L; Tespili M; Repossini A; Rambaldini M
Interact Cardiovasc Thorac Surg; 2015 Jan; 20(1):90-5. PubMed ID: 25320140
[TBL] [Abstract][Full Text] [Related]
39. Small ischemic brain lesions after cardiac valve replacement detected by diffusion-weighted magnetic resonance imaging: relation to neurocognitive function.
Knipp SC; Matatko N; Schlamann M; Wilhelm H; Thielmann M; Forsting M; Diener HC; Jakob H
Eur J Cardiothorac Surg; 2005 Jul; 28(1):88-96. PubMed ID: 15922616
[TBL] [Abstract][Full Text] [Related]
40. Thirty-day outcome after transcatheter aortic valve implantation compared with surgical valve replacement in patients with high-risk aortic stenosis: a matched comparison.
Stöhr R; Dohmen G; Herpertz R; Brehmer K; Aktug O; Koos R; Altiok E; Stegemann E; Autschbach R; Marx N; Hoffmann R
Coron Artery Dis; 2011 Dec; 22(8):595-600. PubMed ID: 22009042
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]