38 related articles for article (PubMed ID: 23152147)
1. The Graphite Calorimeter as a Standard of Absorbed Dose for Cobalt-60 Gamma Radiation.
Pruitt JS; Domen SR; Loevinger R
J Res Natl Bur Stand (1977); 1981; 86(5):495-502. PubMed ID: 34566056
[TBL] [Abstract][Full Text] [Related]
2. RE-EVALUATION OF THE AIR KERMA PRIMARY STANDARD OF THE SMU IN 60Co AND 137Cs GAMMA RAY BEAMS.
Durný N
Radiat Prot Dosimetry; 2019 Dec; 186(2-3):235-238. PubMed ID: 32123913
[TBL] [Abstract][Full Text] [Related]
3. Density effects of silica aerogel insulation on the performance of a graphite probe calorimeter.
Bancheri J; Seuntjens J; Sarfehnia A; Renaud J
Med Phys; 2019 Apr; 46(4):1874-1882. PubMed ID: 30729543
[TBL] [Abstract][Full Text] [Related]
4. Alanine response to low energy synchrotron x-ray radiation.
van den Elzen P; Sander T; Palmans H; McManus M; Woodall N; Lee N; Fox OJL; Jones RM; Angal-Kalinin D; Subiel A
Phys Med Biol; 2023 Mar; 68(6):. PubMed ID: 36731142
[No Abstract] [Full Text] [Related]
5. ASSESSMENT OF THE ABSORBED DOSES IN THE ORGANS IN CASE OF RADIATION EMERGENCY WITH THE SEALED GAMMA-SOURCES.
Golikov V
Radiat Prot Dosimetry; 2019 Nov; 185(1):67-73. PubMed ID: 30544246
[TBL] [Abstract][Full Text] [Related]
6. A Polystyrene-Water Calorimeter.
Domen SR
J Res Natl Bur Stand (1977); 1983; 88(6):373-387. PubMed ID: 34566110
[TBL] [Abstract][Full Text] [Related]
7. A Sealed Water Calorimeter for Measuring Absorbed Dose.
Domen SR
J Res Natl Inst Stand Technol; 1994; 99(2):121-141. PubMed ID: 37404710
[TBL] [Abstract][Full Text] [Related]
8. DEVELOPMENT OF ABSOLUTE MEASUREMENT SYSTEM FOR 𝑾AIR IN 60CO GAMMA RAYS.
Sato Y; Shimizu M; Takeda M; Fujita Y; Kato M; Kurosawa T; Sato M
Radiat Prot Dosimetry; 2023 Mar; 199(3):ncac280 262 269-276. PubMed ID: 36575963
[TBL] [Abstract][Full Text] [Related]
9. An Absorbed Dose Water Calorimeter: Theory, Design, and Performance.
Domen SR
J Res Natl Bur Stand (1977); 1982; 87(3):211-235. PubMed ID: 34566082
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo modelling of experimental setup used for biodosimetry intercomparison.
Gunasekara D; Wilkins R; Tessier F; Beaton-Green L
Radiat Prot Dosimetry; 2023 Sep; 199(14):1551-1556. PubMed ID: 37721067
[TBL] [Abstract][Full Text] [Related]
11. The international measurement system for radionuclide metrology: A strategy for the future.
Karam L; Judge S; Louw W
Appl Radiat Isot; 2019 Dec; 154():108838. PubMed ID: 31442793
[TBL] [Abstract][Full Text] [Related]
12. Activity measurements of the radionuclides
Michotte C; Nonis M; Bergeron D; Cessna J; Fitzgerald R; Pibida L; Zimmerman B; Fenwick A; Ferreira K; Keightley J; Da Silva I
Metrologia; 2017; 54(1A):. PubMed ID: 33100400
[TBL] [Abstract][Full Text] [Related]
13. Recalibration of the U.S. National Prototype Kilogram.
Davis RS
J Res Natl Bur Stand (1977); 1985; 90(4):263-283. PubMed ID: 34566154
[TBL] [Abstract][Full Text] [Related]
14. Statistical Interpretation of Key Comparison Reference Value and Degrees of Equivalence.
Kacker RN; Datla RU; Parr AC
J Res Natl Inst Stand Technol; 2003; 108(6):439-46. PubMed ID: 27413621
[TBL] [Abstract][Full Text] [Related]
15. New Assignment of Mass Values and Uncertainties to NIST Working Standards.
Davis RS
J Res Natl Inst Stand Technol; 1990; 95(1):79-92. PubMed ID: 28179759
[TBL] [Abstract][Full Text] [Related]
16. Direct megavoltage photon calibration service in Australia.
Butler DJ; Ramanathan G; Oliver C; Cole A; Lye J; Harty PD; Wright T; Webb DV; Followill DS
Australas Phys Eng Sci Med; 2014 Dec; 37(4):753-61. PubMed ID: 25146559
[TBL] [Abstract][Full Text] [Related]
17. Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60Co radiation.
Lye JE; Butler DJ; Franich RD; Harty PD; Oliver CP; Ramanathan G; Webb DV; Wright T
Radiat Prot Dosimetry; 2013 Jun; 155(1):100-9. PubMed ID: 23152147
[TBL] [Abstract][Full Text] [Related]
18. Direct calibration in megavoltage photon beams using Monte Carlo conversion factor: validation and clinical implications.
Wright T; Lye JE; Ramanathan G; Harty PD; Oliver C; Webb DV; Butler DJ
Phys Med Biol; 2015 Jan; 60(2):883-904. PubMed ID: 25565406
[TBL] [Abstract][Full Text] [Related]
19. Re-evaluation of correction factors of a primary standard graphite calorimeter in 60Co gamma ray beams as a basis for the appointment of the BEV absorbed dose rate to water reference value.
Baumgartner A; Steurer A; Tiefenböck W; Gabris F; Maringer FJ; Kapsch RP; Stucki G
Radiat Prot Dosimetry; 2011 Apr; 145(1):3-12. PubMed ID: 21112889
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]