These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 23164945)
21. Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states. Kusy RP; Whitley JQ; Prewitt MJ Angle Orthod; 1991; 61(4):293-302. PubMed ID: 1763840 [TBL] [Abstract][Full Text] [Related]
22. Plasma-sprayed hydroxyapatite+titania composite bond coat for hydroxyapatite coating on titanium substrate. Lu YP; Li MS; Li ST; Wang ZG; Zhu RF Biomaterials; 2004 Aug; 25(18):4393-403. PubMed ID: 15046930 [TBL] [Abstract][Full Text] [Related]
23. In vivo comparison of bone formation on titanium implant surfaces coated with biomimetically deposited calcium phosphate or electrochemically deposited hydroxyapatite. Yang GL; He FM; Song E; Hu JA; Wang XX; Zhao SF Int J Oral Maxillofac Implants; 2010; 25(4):669-80. PubMed ID: 20657861 [TBL] [Abstract][Full Text] [Related]
24. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo. Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620 [TBL] [Abstract][Full Text] [Related]
25. Resistance to sliding of titanium brackets tested against stainless steel and beta-titanium archwires with second-order angulation in the dry and wet states. Whitley JQ; Kusy RP Am J Orthod Dentofacial Orthop; 2007 Mar; 131(3):400-11. PubMed ID: 17346598 [TBL] [Abstract][Full Text] [Related]
26. Formation and transformation of amorphous calcium phosphates on titanium alloy surfaces during atmospheric plasma spraying and their subsequent in vitro performance. Heimann RB; Wirth R Biomaterials; 2006 Feb; 27(6):823-31. PubMed ID: 16139352 [TBL] [Abstract][Full Text] [Related]
27. Deformation of orthodontic archwires over time. Wong EK; Borland DW; West VC Aust Orthod J; 1994 Oct; 13(3):152-8. PubMed ID: 8975645 [TBL] [Abstract][Full Text] [Related]
29. Should the galvanic combination of titanium and stainless steel surgical implants be avoided? Høl PJ; Mølster A; Gjerdet NR Injury; 2008 Feb; 39(2):161-9. PubMed ID: 18054018 [TBL] [Abstract][Full Text] [Related]
30. Adhesive bond of veneering composites on various metal surfaces using silicoating, titanium-coating or functional monomers. Behr M; Rosentritt M; Gröger G; Handel G J Dent; 2003 Jan; 31(1):33-42. PubMed ID: 12615018 [TBL] [Abstract][Full Text] [Related]
31. Response of duplex Cr(N)/S and Cr(C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditions. Sun Y; Dearnley PA; Mallia B J Biomed Mater Res B Appl Biomater; 2017 Aug; 105(6):1503-1513. PubMed ID: 27120400 [TBL] [Abstract][Full Text] [Related]
32. Correlation between rate of bony ingrowth to stainless steel, pure titanium, and titanium alloy implants in vivo and formation of hydroxyapatite on their surfaces in vitro. Oron A; Agar G; Oron U; Stein A J Biomed Mater Res A; 2009 Dec; 91(4):1006-9. PubMed ID: 19097149 [TBL] [Abstract][Full Text] [Related]
33. Correlation between vertical misfits and stresses transmitted to implants from metal frameworks. de Torres EM; Barbosa GA; Bernardes SR; de Mattos Mda G; Ribeiro RF J Biomech; 2011 Jun; 44(9):1735-9. PubMed ID: 21497352 [TBL] [Abstract][Full Text] [Related]
34. Force-deflection properties of initial orthodontic archwires. Quintão CC; Cal-Neto JP; Menezes LM; Elias CN World J Orthod; 2009; 10(1):29-32. PubMed ID: 19388430 [TBL] [Abstract][Full Text] [Related]
35. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants. Brien WW; Salvati EA; Betts F; Bullough P; Wright T; Rimnac C; Buly R; Garvin K Clin Orthop Relat Res; 1992 Mar; (276):66-74. PubMed ID: 1537176 [TBL] [Abstract][Full Text] [Related]
36. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates. Krischak GD; Gebhard F; Mohr W; Krivan V; Ignatius A; Beck A; Wachter NJ; Reuter P; Arand M; Kinzl L; Claes LE Arch Orthop Trauma Surg; 2004 Mar; 124(2):104-13. PubMed ID: 14727127 [TBL] [Abstract][Full Text] [Related]
37. The effect of stainless steel, cobalt-chromium, titanium alloy, and titanium on the respiratory burst activity of human polymorphonuclear leukocytes. Pascual A; Tsukayama DT; Wicklund BH; Bechtold JE; Merritt K; Peterson PK; Gustilo RB Clin Orthop Relat Res; 1992 Jul; (280):281-8. PubMed ID: 1319292 [TBL] [Abstract][Full Text] [Related]
38. Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys. Merritt K; Brown SA J Biomed Mater Res; 1995 May; 29(5):627-33. PubMed ID: 7622548 [TBL] [Abstract][Full Text] [Related]
39. Structural, microstructural, and residual stress investigations of plasma-sprayed hydroxyapatite on Ti-6Al-4 V. Carradó A ACS Appl Mater Interfaces; 2010 Feb; 2(2):561-5. PubMed ID: 20356205 [TBL] [Abstract][Full Text] [Related]
40. The role of calcium gluconate in electrochemical activation of titanium for biomimetic coating of calcium phosphate. Shibli SM; Mathai S J Biomed Mater Res A; 2008 Dec; 87(4):994-1002. PubMed ID: 18257080 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]