These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
361 related articles for article (PubMed ID: 23167262)
1. The LMA-Supreme™ as an intubation conduit in patients with known difficult airways: a prospective evaluation study. van Zundert TC; Wong DT; van Zundert AA Acta Anaesthesiol Scand; 2013 Jan; 57(1):77-81. PubMed ID: 23167262 [TBL] [Abstract][Full Text] [Related]
2. Brief review: The LMA Supreme™ supraglottic airway. Wong DT; Yang JJ; Jagannathan N Can J Anaesth; 2012 May; 59(5):483-93. PubMed ID: 22318376 [TBL] [Abstract][Full Text] [Related]
3. Use of intubation introducers through a supraglottic airway to facilitate tracheal intubation: a brief review. Wong DT; Yang JJ; Mak HY; Jagannathan N Can J Anaesth; 2012 Jul; 59(7):704-15. PubMed ID: 22653838 [TBL] [Abstract][Full Text] [Related]
4. Tracheal intubation in an unanticipated difficult airway by advancing a bronchoscope and a tracheal tube introducer through a LMA Supreme™. Chu QJ; Han XP; Mak HY; Wong DT Can J Anaesth; 2012 Feb; 59(2):234-5. PubMed ID: 22076862 [No Abstract] [Full Text] [Related]
5. [Comparison of Cookgas and Fastrach intubating laryngeal mask airway with fiberoptic bronchoscope in anticipated difficult airway management]. Yang D; Deng XM; Tong SY; Tang GZ; Zhang YM; Wei LX; Sui JH; Sun YL; Liu JH; Wang L; Liu XW Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2013 Oct; 35(5):477-82. PubMed ID: 24183034 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of air-Q™ intubating laryngeal airway as a conduit for tracheal intubation in infants--a pilot study. Sinha R; Chandralekha ; Ray BR Paediatr Anaesth; 2012 Feb; 22(2):156-60. PubMed ID: 21973052 [TBL] [Abstract][Full Text] [Related]
7. [Use of the Airtraq by inexperienced physicians supervised during a series of tracheal intubation in adult patient with anticipated difficult airway]. Giquello JA; Humbert S; Duc F; Monrigal JP; Granry JC Ann Fr Anesth Reanim; 2011 Nov; 30(11):804-8. PubMed ID: 21719241 [TBL] [Abstract][Full Text] [Related]
8. Intubation via LMA in pediatric patients with difficult airways. Selim M; Mowafi H; Al-Ghamdi A; Adu-Gyamfi Y Can J Anaesth; 1999 Sep; 46(9):891-3. PubMed ID: 10490160 [TBL] [Abstract][Full Text] [Related]
9. Distance from the glottis to the grille: the LMA Unique, Air-Q and CobraPLA as intubation conduits: a randomised trial. Schebesta K; Karanovic G; Krafft P; Rössler B; Kimberger O Eur J Anaesthesiol; 2014 Mar; 31(3):159-65. PubMed ID: 24257457 [TBL] [Abstract][Full Text] [Related]
10. I-gel Versus LMA-Fastrach Supraglottic Airway for Flexible Bronchoscope-Guided Tracheal Intubation Using a Parker (GlideRite) Endotracheal Tube: A Randomized Controlled Trial. Moore A; Gregoire-Bertrand F; Massicotte N; Gauthier A; Lallo A; Ruel M; Todorov A; Girard F Anesth Analg; 2015 Aug; 121(2):430-6. PubMed ID: 26076387 [TBL] [Abstract][Full Text] [Related]
11. Tracheal intubation through the I-gel™ supraglottic airway versus the LMA Fastrach™: a randomized controlled trial. Halwagi AE; Massicotte N; Lallo A; Gauthier A; Boudreault D; Ruel M; Girard F Anesth Analg; 2012 Jan; 114(1):152-6. PubMed ID: 22075016 [TBL] [Abstract][Full Text] [Related]
12. Use of the Laryngeal Mask Airway-Aintree Intubating Catheter-fiberoptic bronchoscope technique for difficult intubation. Berkow LC; Schwartz JM; Kan K; Corridore M; Heitmiller ES J Clin Anesth; 2011 Nov; 23(7):534-9. PubMed ID: 21996015 [TBL] [Abstract][Full Text] [Related]
13. A feasibility study using the VivaSight Single Lumen™ to intubate the trachea through the Fastrach laryngeal mask airway: a preliminary report of 50 cases. Gaitini LA; Yanovski B; Mustafa S; Hagberg CA; Mora PC; Vaida SJ Anesth Analg; 2013 Mar; 116(3):604-8. PubMed ID: 23400984 [TBL] [Abstract][Full Text] [Related]
14. Retrospective audit of the air-Q intubating laryngeal airway as a conduit for tracheal intubation in pediatric patients with a difficult airway. Jagannathan N; Kho MF; Kozlowski RJ; Sohn LE; Siddiqui A; Wong DT Paediatr Anaesth; 2011 Apr; 21(4):422-7. PubMed ID: 21175955 [TBL] [Abstract][Full Text] [Related]
15. Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients. Theiler LG; Kleine-Brueggeney M; Kaiser D; Urwyler N; Luyet C; Vogt A; Greif R; Unibe MM Anesthesiology; 2009 Jul; 111(1):55-62. PubMed ID: 19512881 [TBL] [Abstract][Full Text] [Related]
16. Pediatric supraglottic airway devices in clinical practice: A prospective observational study. Kleine-Brueggeney M; Gottfried A; Nabecker S; Greif R; Book M; Theiler L BMC Anesthesiol; 2017 Sep; 17(1):119. PubMed ID: 28865448 [TBL] [Abstract][Full Text] [Related]
17. Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients. Joly N; Poulin LP; Tanoubi I; Drolet P; Donati F; St-Pierre P Can J Anaesth; 2014 Sep; 61(9):794-800. PubMed ID: 25141831 [TBL] [Abstract][Full Text] [Related]
18. Air-Q Portas M; Canal MI; Barrio M; Alonso M; Cabrerizo P; López-Gil M; Zaballos M Rev Esp Anestesiol Reanim (Engl Ed); 2018 Mar; 65(3):135-142. PubMed ID: 29217156 [TBL] [Abstract][Full Text] [Related]
19. Intubation via the LMA using a Cook retrograde intubation kit. Arndt GA; Topp J; Hannah J; McDowell TS; Lesko A Can J Anaesth; 1998 Mar; 45(3):257-60. PubMed ID: 9579265 [TBL] [Abstract][Full Text] [Related]
20. Tracheal intubation via the Classic and Proseal laryngeal mask airways: a manikin study using the Aintree Intubating Catheter. Blair EJ; Mihai R; Cook TM Anaesthesia; 2007 Apr; 62(4):385-7. PubMed ID: 17381576 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]