7. Rates of revision and device failure in cochlear implant surgery: a 30-year experience. Wang JT; Wang AY; Psarros C; Da Cruz M Laryngoscope; 2014 Oct; 124(10):2393-9. PubMed ID: 24550135 [TBL] [Abstract][Full Text] [Related]
8. Revision cochlear implant surgery in children. Cullen RD; Fayad JN; Luxford WM; Buchman CA Otol Neurotol; 2008 Feb; 29(2):214-20. PubMed ID: 18223449 [TBL] [Abstract][Full Text] [Related]
9. Cochlear implant complications in 403 patients: comparative study of adults and children and review of the literature. Farinetti A; Ben Gharbia D; Mancini J; Roman S; Nicollas R; Triglia JM Eur Ann Otorhinolaryngol Head Neck Dis; 2014 Jun; 131(3):177-82. PubMed ID: 24889283 [TBL] [Abstract][Full Text] [Related]
10. Revision surgeries and medical interventions in young cochlear implant recipients. Lescanne E; Al Zahrani M; Bakhos D; Robier A; Morinière S Int J Pediatr Otorhinolaryngol; 2011 Oct; 75(10):1221-4. PubMed ID: 21813189 [TBL] [Abstract][Full Text] [Related]
11. Surgical and medical management for complications in 475 consecutive pediatric cochlear implantations. Tarkan Ö; Tuncer Ü; Özdemir S; Sürmelioğlu Ö; Çetik F; Kıroğlu M; Kayıkçıoğlu E; Kara K Int J Pediatr Otorhinolaryngol; 2013 Apr; 77(4):473-9. PubMed ID: 23290867 [TBL] [Abstract][Full Text] [Related]
12. Cochlear implant failures: lessons learned from a UK centre. Masterson L; Kumar S; Kong JH; Briggs J; Donnelly N; Axon PR; Gray RF J Laryngol Otol; 2012 Jan; 126(1):15-21. PubMed ID: 22032544 [TBL] [Abstract][Full Text] [Related]
13. Revision cochlear implantation with different electrodes can cause incomplete electrode insertion and poor performance. Shin SH; Park S; Lee WS; Kim HN; Choi JY Otol Neurotol; 2013 Apr; 34(3):549-53. PubMed ID: 23478649 [TBL] [Abstract][Full Text] [Related]
14. Pediatric cochlear implant revision surgery and reimplantation: an analysis of 957 cases. Olgun Y; Bayrak AF; Catli T; Ceylan ME; Aydin R; Duzenli U; Olgun L Int J Pediatr Otorhinolaryngol; 2014 Oct; 78(10):1642-7. PubMed ID: 25128446 [TBL] [Abstract][Full Text] [Related]
18. Evaluating Reasons for Revision Surgery and Device Failure Rates in Patients Who Underwent Cochlear Implantation Surgery. Kim SY; Kim MB; Chung WH; Cho YS; Hong SH; Moon IJ JAMA Otolaryngol Head Neck Surg; 2020 May; 146(5):414-420. PubMed ID: 32134441 [TBL] [Abstract][Full Text] [Related]
19. Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry. Donnelly N; Bibas A; Jiang D; Bamiou DE; Santulli C; Jeronimidis G; Fitzgerald O'Connor A J Laryngol Otol; 2009 Jul; 123(7):723-9. PubMed ID: 19138455 [TBL] [Abstract][Full Text] [Related]