138 related articles for article (PubMed ID: 23179787)
1. Evaluation of chronic ischemic heart disease with myocardial perfusion and regional contraction analysis by contrast-enhanced 256-MSCT.
Higuchi K; Nagao M; Matsuo Y; Kamitani T; Yonezawa M; Jinnouchi M; Yamasaki Y; Abe K; Baba S; Mukai Y; Higo T; Sunagawa K; Honda H
Jpn J Radiol; 2013 Feb; 31(2):123-32. PubMed ID: 23179787
[TBL] [Abstract][Full Text] [Related]
2. The value of attenuation correction by hybrid SPECT/CT imaging on infarct size quantification in male patients with previous inferior myocardial infarct.
Giubbini RM; Gabanelli S; Lucchini S; Merli G; Puta E; Rodella C; Motta F; Paghera B; Rossini P; Terzi A; Bertagna F
Nucl Med Commun; 2011 Nov; 32(11):1026-32. PubMed ID: 21897308
[TBL] [Abstract][Full Text] [Related]
3. Diagnostic Accuracy of Noninvasive 64-row Computed Tomographic Coronary Angiography (CCTA) Compared with Myocardial Perfusion Imaging (MPI): The PICTURE Study, A Prospective Multicenter Trial.
Budoff MJ; Li D; Kazerooni EA; Thomas GS; Mieres JH; Shaw LJ
Acad Radiol; 2017 Jan; 24(1):22-29. PubMed ID: 27771227
[TBL] [Abstract][Full Text] [Related]
4. Quantification of myocardial perfusion by contrast-enhanced 64-MDCT: characterization of ischemic myocardium.
Nagao M; Matsuoka H; Kawakami H; Higashino H; Mochizuki T; Murase K; Uemura M
AJR Am J Roentgenol; 2008 Jul; 191(1):19-25. PubMed ID: 18562719
[TBL] [Abstract][Full Text] [Related]
5. Myocardial ischemia detection with single-phase CT perfusion in symptomatic patients using high-pitch helical image acquisition technique.
Bischoff B; Deseive S; Rampp M; Todica A; Wermke M; Martinoff S; Massberg S; Reiser MF; Becker HC; Hausleiter J
Int J Cardiovasc Imaging; 2017 Apr; 33(4):569-576. PubMed ID: 27848163
[TBL] [Abstract][Full Text] [Related]
6. Diagnostic Performance of First-Pass Myocardial Perfusion Imaging without Stress with Computed Tomography (CT) Compared with Coronary CT Angiography Alone, with Fractional Flow Reserve as the Reference Standard.
Osawa K; Miyoshi T; Miki T; Koyama Y; Sato S; Kanazawa S; Ito H
PLoS One; 2016; 11(2):e0149170. PubMed ID: 26894686
[TBL] [Abstract][Full Text] [Related]
7. Assessment of the myocardium on 2-phase cardiac multidetector computed tomography: does cyclic cardiac contraction influence myocardial attenuation?
Boll DT; Merkle EM; Paulson EK; Hoffmann MH
J Comput Assist Tomogr; 2008; 32(4):602-8. PubMed ID: 18664849
[TBL] [Abstract][Full Text] [Related]
8. Detection of myocardial ischemia using 64-slice MDCT.
Nagao M; Matsuoka H; Kawakami H; Higashino H; Mochizuki T; Ohshita A; Kohno T; Shigemi S
Circ J; 2009 May; 73(5):905-11. PubMed ID: 19325193
[TBL] [Abstract][Full Text] [Related]
9. Comparison of the extent and severity of myocardial perfusion defects measured by CT coronary angiography and SPECT myocardial perfusion imaging.
Tamarappoo BK; Dey D; Nakazato R; Shmilovich H; Smith T; Cheng VY; Thomson LE; Hayes SW; Friedman JD; Germano G; Slomka PJ; Berman DS
JACC Cardiovasc Imaging; 2010 Oct; 3(10):1010-9. PubMed ID: 20947046
[TBL] [Abstract][Full Text] [Related]
10. Non-contrast cardiac computed tomography can accurately detect chronic myocardial infarction: Validation study.
Gupta M; Kadakia J; Hacioglu Y; Ahmadi N; Patel A; Choi T; Yamada G; Budoff M
J Nucl Cardiol; 2011 Feb; 18(1):96-103. PubMed ID: 21128040
[TBL] [Abstract][Full Text] [Related]
11. Adenosine-stress dynamic myocardial perfusion imaging with second-generation dual-source CT: comparison with conventional catheter coronary angiography and SPECT nuclear myocardial perfusion imaging.
Wang Y; Qin L; Shi X; Zeng Y; Jing H; Schoepf UJ; Jin Z
AJR Am J Roentgenol; 2012 Mar; 198(3):521-9. PubMed ID: 22357991
[TBL] [Abstract][Full Text] [Related]
12. Myocardial CT perfusion imaging and atherosclerotic plaque characteristics on coronary CT angiography for the identification of myocardial ischaemia.
Wang J; Chen HW; Fang XM; Qian PY; Ding GL; Xu ML
Clin Radiol; 2019 Oct; 74(10):763-768. PubMed ID: 31239108
[TBL] [Abstract][Full Text] [Related]
13. Ischemic burden assessment of myocardial perfusion CT, compared with SPECT using semi-quantitative and quantitative approaches.
Kwon O; Hwang HJ; Koo HJ; Yang DH; Kang HJ; Kim JA; Moon DH; Kim HS; Kang JW; Kim YH
Int J Cardiol; 2019 Mar; 278():287-294. PubMed ID: 30587418
[TBL] [Abstract][Full Text] [Related]
14. Coronary Computed Tomography Angiography Compared With Single Photon Emission Computed Tomography Myocardial Perfusion Imaging as a Guide to Optimal Medical Therapy in Patients Presenting With Stable Angina: The RESCUE Trial.
Stillman AE; Gatsonis C; Lima JAC; Liu T; Snyder BS; Cormack J; Malholtra V; Schnall MD; Udelson JE; Hoffmann U; Woodard PK;
J Am Heart Assoc; 2020 Dec; 9(24):e017993. PubMed ID: 33283579
[TBL] [Abstract][Full Text] [Related]
15. Detection and quantification of myocardial perfusion defects by resting single-phase 64-slice cardiac computed tomography angiography compared with SPECT myocardial perfusion imaging.
Gupta M; Kadakia J; Jug B; Mao SS; Budoff MJ
Coron Artery Dis; 2013 Jun; 24(4):290-7. PubMed ID: 23442945
[TBL] [Abstract][Full Text] [Related]
16. Integrated assessment of coronary anatomy and myocardial perfusion using a retractable SPECT camera combined with 64-slice CT: initial experience.
Thilo C; Schoepf UJ; Gordon L; Chiaramida S; Serguson J; Costello P
Eur Radiol; 2009 Apr; 19(4):845-56. PubMed ID: 18972115
[TBL] [Abstract][Full Text] [Related]
17. Optimal timing of image acquisition for arterial first pass CT myocardial perfusion imaging.
Pelgrim GJ; Nieuwenhuis ER; Duguay TM; van der Geest RJ; Varga-Szemes A; Slump CH; Fuller SR; Oudkerk M; Schoepf UJ; Vliegenthart R
Eur J Radiol; 2017 Jan; 86():227-233. PubMed ID: 28027752
[TBL] [Abstract][Full Text] [Related]
18. Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease.
George RT; Arbab-Zadeh A; Miller JM; Vavere AL; Bengel FM; Lardo AC; Lima JA
Circ Cardiovasc Imaging; 2012 May; 5(3):333-40. PubMed ID: 22447807
[TBL] [Abstract][Full Text] [Related]
19. Ejection fractions determined by cardiac computed tomographic angiography and single photon emission computed tomographic myocardial perfusion imaging are not interchangeable: evidence of significant and sex-associated disparities.
Mehta A; Travin MI; Levsky JM; Jain VR; Burton WB; Haramati LB
J Comput Assist Tomogr; 2009; 33(4):489-97. PubMed ID: 19638838
[TBL] [Abstract][Full Text] [Related]
20. Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT.
Fukami M; Tamura K; Nakamura Y; Nakatsukasa S; Sasaki M
Radiol Phys Technol; 2020 Mar; 13(1):20-26. PubMed ID: 31768935
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]