These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 23180538)

  • 1. [Change of defibrillation vector with addition of an azygos vein coil lowers defibrillation threshold].
    Jastrzębski M; Czarnecka D
    Kardiol Pol; 2012; 70(11):1202-4. PubMed ID: 23180538
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The azygos defibrillator lead for elevated defibrillation thresholds: implant technique, lead stability, and patient series.
    Cooper JA; Latacha MP; Soto GE; Garmany RG; Gleva MJ; Chen J; Faddis MN; Smith TW
    Pacing Clin Electrophysiol; 2008 Nov; 31(11):1405-10. PubMed ID: 18950297
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemiazygous coil placement for high-defibrillation thresholds in a patient with a right-sided implantable cardioverter defibrillator.
    Nilsson KR; Jackson KP
    Pacing Clin Electrophysiol; 2012 Jan; 35(1):e10-2. PubMed ID: 20723090
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Azygous vein coil lowers defibrillation threshold in patients with high defibrillation threshold.
    Seow SC; Tolentino CS; Zhao J; Lim TW
    Europace; 2011 Jun; 13(6):825-8. PubMed ID: 21436136
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Successful reduction of a high defibrillation threshold by a combined implantation of a subcutaneous array and azygos vein lead.
    Yamada T; Robertson PG; McElderry HT; Doppalapudi H; Plumb VJ; Kay GN
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e173-6. PubMed ID: 22360586
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Achieving low defibrillation thresholds at implant: pharmacological influences, RV coil polarity and position, SVC coil usage and positioning, pulse width settings, and the azygous vein.
    Kroll MW; Schwab JO
    Fundam Clin Pharmacol; 2010 Oct; 24(5):561-73. PubMed ID: 20608994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Azygos vein lead implantation: a novel adjunctive technique for implantable cardioverter defibrillator placement.
    Cesario D; Bhargava M; Valderrábano M; Fonarow GC; Wilkoff B; Shivkumar K
    J Cardiovasc Electrophysiol; 2004 Jul; 15(7):780-3. PubMed ID: 15250862
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Factors predisposing to ventricular tachyarrhythmia leading to appropriate ICD intervention in patients with coronary artery disease or non-ischaemic dilated cardiomyopathy.
    Lelakowski J; Piekarz J; Rydlewska A; Majewski J; Senderek T; Ząbek A; Małecka B
    Kardiol Pol; 2012; 70(12):1264-75. PubMed ID: 23264245
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictors of successful defibrillation threshold test during CRT-D implantation.
    Przybylski A; Oreziak A; Lewandowski Z; Hasiec A; Orczykowski M; Walczak F
    Kardiol Pol; 2010 May; 68(5):512-8. PubMed ID: 20491010
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).
    Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S
    Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Successful implantation of a biventricular pacing and defibrillator device via a persistent left superior vena cava.
    Vukmirović M; Angelkov L; Vukmirović F; Vukmirović IT
    Vojnosanit Pregl; 2013 Dec; 70(12):1162-4. PubMed ID: 24450264
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High defibrillation threshold with right-sided ICD implantation was resolved by a dual coil lead via persistent left superior vena cava.
    Fujito T; Nagahara D; Tsuzuki T; Kamiyama N; Mochizuki A; Miura T
    J Cardiol Cases; 2022 May; 25(5):262-265. PubMed ID: 35582083
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implantable cardioverter defibrillator lead placement in the middle cardiac vein after tricuspid valve surgery.
    Lopez JA
    Europace; 2012 Jun; 14(6):853-8. PubMed ID: 22333241
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimal electrode position for transvenous defibrillation: a prospective randomized study.
    Stajduhar KC; Ott GY; Kron J; McAnulty JH; Oliver RP; Reynolds BT; Adler SW; Halperin BD
    J Am Coll Cardiol; 1996 Jan; 27(1):90-4. PubMed ID: 8522716
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Examination of a middle cardiac vein defibrillation coil as stand-alone anode, auxiliary anode, and bystander electrode in a transvenous defibrillation circuit.
    Paisey JR; Yue AM; Bessoule F; Allen S; Roberts PR; Morgan JM
    Pacing Clin Electrophysiol; 2004 Aug; 27(8):1089-93. PubMed ID: 15305957
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Implantation of defibrillators with transvenous-subcutaneous electrode systems].
    Hief C; Podczeck A; Veit F; Frohner K; Kaltenbrunner W; Nürnberg M; Steinbach K
    Wien Klin Wochenschr; 1993; 105(1):12-6. PubMed ID: 8438594
    [TBL] [Abstract][Full Text] [Related]  

  • 17. No benefit of a dual coil over a single coil ICD lead: evidence from the Sudden Cardiac Death in Heart Failure Trial.
    Aoukar PS; Poole JE; Johnson GW; Anderson J; Hellkamp AS; Mark DB; Lee KL; Bardy GH
    Heart Rhythm; 2013 Jul; 10(7):970-6. PubMed ID: 23562699
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low defibrillation threshold in a patient with a dual-coil defibrillator lead implanted through a persistent left superior vena cava.
    Williams TA; Abe O; Mitre CA; Kassotis J
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):e274-5. PubMed ID: 22650311
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Subcutaneous array to transvenous proximal coil defibrillation as a solution to high defibrillation thresholds with implantable cardioverter defibrillator distal coil failure.
    Avitall B; Oza SR; Gonzalez R; Avery R
    J Cardiovasc Electrophysiol; 2003 Mar; 14(3):314-5. PubMed ID: 12716117
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a novel ventricular support device with defibrillation capabilities in canine and porcine animal models.
    Killingsworth CR; Rippy MK; Virmani R; Rollins DL; McGiffin DC; Ideker RE
    J Cardiovasc Electrophysiol; 2008 Aug; 19(8):851-7. PubMed ID: 18373602
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.