These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 23198394)

  • 1. Development of a new arterial-line filter design using computational fluid dynamics analysis.
    Herbst DP; Najm HK
    J Extra Corpor Technol; 2012 Sep; 44(3):139-44. PubMed ID: 23198394
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of Micropore Filter Technology: Exploring the Blood Flow Path in Arterial-Line Filters and Its Effect on Bubble Trapping Functions.
    Herbst DP
    J Extra Corpor Technol; 2017 Mar; 49(1):44-48. PubMed ID: 28298665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype.
    Herbst DP
    J Extra Corpor Technol; 2014 Sep; 46(3):239-50. PubMed ID: 26357790
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters.
    Herbst DP
    J Extra Corpor Technol; 2016 Sep; 48(3):105-112. PubMed ID: 27729703
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computational fluid dynamics verified the advantages of streamlined impeller design in improving flow patterns and anti-haemolysis properties of centrifugal pump.
    Qian KX; Wang FQ; Zeng P; Ru WM; Yuan HY; Feng ZG
    J Med Eng Technol; 2006; 30(6):353-7. PubMed ID: 17060163
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of local flow ratios and velocities in a femoral venous cannula with computational fluid dynamics and 4D flow-sensitive magnetic resonance imaging: A method validation.
    Rauh P; Benk C; Beyersdorf F; Russe M
    Artif Organs; 2021 May; 45(5):506-515. PubMed ID: 33185904
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of different filter positions and combinations in extracorporeal circulation.
    Krebber HJ; Hill JD; Osborn JJ; Iatridis A; Gerbode F
    Artif Organs; 1980 Aug; 4(3):167-70. PubMed ID: 7417029
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling centrifugal cell washers using computational fluid dynamics.
    Kellet BE; Han B; Dandy DS; Wickramasinghe SR
    Artif Organs; 2004 Nov; 28(11):1026-34. PubMed ID: 15504118
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical analysis of the hemodynamics and embolus capture of a greenfield vena cava filter.
    Swaminathan TN; Hu HH; Patel AA
    J Biomech Eng; 2006 Jun; 128(3):360-70. PubMed ID: 16706585
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modeling blood flow in a tilted inferior vena cava filter: does tilt adversely affect hemodynamics?
    Singer MA; Wang SL
    J Vasc Interv Radiol; 2011 Feb; 22(2):229-35. PubMed ID: 21211992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Release of particulate matter from extracorporeal tubing: ineffectiveness of standard arterial line filters during bypass.
    Knopp EA; Baumann FG; Pratt D; Faden R; Catinella FP; Nathan IM; Adams PX; Cunningham JN; Spencer FC
    J Cardiovasc Surg (Torino); 1982; 23(6):470-6. PubMed ID: 7153235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fetal cardiac bypass using an in-line axial flow pump to minimize extracorporeal surface and avoid priming volume.
    Reddy VM; Liddicoat JR; Klein JR; McElhinney DB; Wampler RK; Hanley FL
    Ann Thorac Surg; 1996 Aug; 62(2):393-400. PubMed ID: 8694597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Errors in flow and pressure related to the arterial filter purge line.
    Lee-Sensiba K; Azzaretto N; Carolina C; DiCarmine N; Hymowitz D; Kay S; Kooker K; Salogub M; Wong E; Tamari Y
    J Extra Corpor Technol; 1998 Jun; 30(2):77-82. PubMed ID: 10182117
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.
    Norman MJ; Sistino JJ; Acsell JR
    J Extra Corpor Technol; 2004 Dec; 36(4):336-42. PubMed ID: 15679274
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-dimensional computational model of a blood oxygenator reconstructed from micro-CT scans.
    D'Onofrio C; van Loon R; Rolland S; Johnston R; North L; Brown S; Phillips R; Sienz J
    Med Eng Phys; 2017 Sep; 47():190-197. PubMed ID: 28716304
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Product design and its relation to the generation of gaseous microemboli in the extracorporeal circuit.
    Servas FM
    Med Instrum; 1985; 19(2):63-6. PubMed ID: 4000008
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three-dimensional flow patterns in the feto-placental vasculature system of the mouse placenta.
    Shannon AT; Mirbod P
    Microvasc Res; 2017 May; 111():88-95. PubMed ID: 28111314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Study of the filtration performance of a plain wave fabric filter using response surface methodology.
    Qian F; Wang H
    J Hazard Mater; 2010 Apr; 176(1-3):559-68. PubMed ID: 20004514
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter.
    Salavitabar A; Qiu F; Kunselman A; Ündar A
    Perfusion; 2010 Nov; 25(6):409-15. PubMed ID: 20699287
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational modeling of blood flow in the TrapEase inferior vena cava filter.
    Singer MA; Henshaw WD; Wang SL
    J Vasc Interv Radiol; 2009 Jun; 20(6):799-805. PubMed ID: 19406666
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.