BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 23200382)

  • 21. An electro-catalytic biosensor fabricated with Pt-Au nanoparticle-decorated titania nanotube array.
    Kang Q; Yang L; Cai Q
    Bioelectrochemistry; 2008 Nov; 74(1):62-5. PubMed ID: 18614406
    [TBL] [Abstract][Full Text] [Related]  

  • 22. New carbosilane polymers with interacting ferrocenes as support and bioelectrocatalysts of oxidases to develop versatile and specific amperometric biodevices.
    Armada MP; Jiménez A; Losada J; Alonso B; Casado CM
    Appl Biochem Biotechnol; 2012 Dec; 168(7):1778-91. PubMed ID: 22971836
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Polypyrrole nanotube array sensor for enhanced adsorption of glucose oxidase in glucose biosensors.
    Ekanayake EM; Preethichandra DM; Kaneto K
    Biosens Bioelectron; 2007 Aug; 23(1):107-13. PubMed ID: 17475472
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Preparation of Pt/polypyrrole-para toluene sulfonate hydrogen peroxide sensitive electrode for the utilizing as a biosensor.
    Çete S; Bal Ö
    Artif Cells Nanomed Biotechnol; 2013 Dec; 41(6):414-20. PubMed ID: 23336613
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Efficient immobilization of glucose oxidase by in situ photo-cross-linking for glucose biosensing.
    Fu G; Dai Z
    Talanta; 2012 Aug; 97():438-44. PubMed ID: 22841105
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Microfluidic bioassay system based on microarrays of hydrogel sensing elements entrapping quantum dot-enzyme conjugates.
    Jang E; Kim S; Koh WG
    Biosens Bioelectron; 2012 Jan; 31(1):529-36. PubMed ID: 22177543
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Amperometric glucose biosensor based on multilayer films via layer-by-layer self-assembly of multi-wall carbon nanotubes, gold nanoparticles and glucose oxidase on the Pt electrode.
    Wu BY; Hou SH; Yin F; Zhao ZX; Wang YY; Wang XS; Chen Q
    Biosens Bioelectron; 2007 Jun; 22(12):2854-60. PubMed ID: 17212983
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Parallel synthesis of libraries of anodic and cathodic functionalized electrodeposition paints as immobilization matrix for amperometric biosensors.
    Ngounou B; Aliyev EH; Guschin DA; Sultanov YM; Efendiev AA; Schuhmann W
    Bioelectrochemistry; 2007 Sep; 71(1):81-90. PubMed ID: 17092781
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An amperometric biosensor for fish freshness detection from xanthine oxidase immobilized in polypyrrole-polyvinylsulphonate film.
    Dolmaci N; Çete S; Arslan F; Yaşar A
    Artif Cells Blood Substit Immobil Biotechnol; 2012 Aug; 40(4):275-9. PubMed ID: 22248304
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Immobilization of glucose oxidase on electrodeposited nickel oxide nanoparticles: direct electron transfer and electrocatalytic activity.
    Salimi A; Sharifi E; Noorbakhsh A; Soltanian S
    Biosens Bioelectron; 2007 Jun; 22(12):3146-53. PubMed ID: 17368016
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biocompatibility of CS-PPy nanocomposites and their application to glucose biosensor.
    Fang Y; Ni Y; Zhang G; Mao C; Huang X; Shen J
    Bioelectrochemistry; 2012 Dec; 88():1-7. PubMed ID: 22750413
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of amperometric glucose biosensor through immobilizing enzyme in a Pt nanoparticles/mesoporous carbon matrix.
    Yu J; Yu D; Zhao T; Zeng B
    Talanta; 2008 Feb; 74(5):1586-91. PubMed ID: 18371821
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor.
    Kausaite-Minkstimiene A; Mazeiko V; Ramanaviciene A; Ramanavicius A
    Biosens Bioelectron; 2010 Oct; 26(2):790-7. PubMed ID: 20638831
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film.
    Wu H; Wang J; Kang X; Wang C; Wang D; Liu J; Aksay IA; Lin Y
    Talanta; 2009 Nov; 80(1):403-6. PubMed ID: 19782243
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A biosensor prepared by co-entrapment of a glucose oxidase and a carbon nanotube within an electrochemically deposited redox polymer multilayer.
    Gao Q; Guo Y; Liu J; Yuan X; Qi H; Zhang C
    Bioelectrochemistry; 2011 Jun; 81(2):109-13. PubMed ID: 21570925
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Glucose biosensor based on electrodeposition of platinum nanoparticles onto carbon nanotubes and immobilizing enzyme with chitosan-SiO(2) sol-gel.
    Zou Y; Xiang C; Sun LX; Xu F
    Biosens Bioelectron; 2008 Feb; 23(7):1010-6. PubMed ID: 18054479
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposome-encapsulated glucose oxidase.
    Graça JS; de Oliveira RF; de Moraes ML; Ferreira M
    Bioelectrochemistry; 2014 Apr; 96():37-42. PubMed ID: 24491835
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers.
    Alonso B; Armada PG; Losada J; Cuadrado I; González B; Casado CM
    Biosens Bioelectron; 2004 Jul; 19(12):1617-25. PubMed ID: 15142595
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An amperometric glucose biosensor based on poly(o-aminophenol) and Prussian blue films at platinum electrode.
    Pan D; Chen J; Nie L; Tao W; Yao S
    Anal Biochem; 2004 Jan; 324(1):115-22. PubMed ID: 14654053
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The construction of glucose biosensor based on platinum nanoclusters-multiwalled carbon nanotubes nanocomposites.
    Wang CY; Tan XR; Chen SH; Hu FX; Zhong HA; Zhang Y
    Appl Biochem Biotechnol; 2012 Feb; 166(4):889-902. PubMed ID: 22215252
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.